An Examination of Various Evaluation Tests for Paper Sizing - A Proposal to Use the Klemm Test for Sizing Evaluation

被引:1
|
作者
Tai, Noriyuki [1 ]
Yamauchi, Tatsuo [2 ]
机构
[1] Arakawa Chem Ind LTD, R&D Dept, Tsurumi Ku, Osaka 5380053, Japan
[2] Kyoto Univ, Grad Sch Agr, Sakyo Ku, Kyoto 6068502, Japan
关键词
D O I
10.2115/fiber.69.96
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
This study compared various sizing evaluation tests, including the Stockigt and Cobb tests as the most popular methods, by using papers of varied basis weight and varied dose of sizing agent. Many tests, including Stockigt, Hercules, KBB and Cobb, are severely affected by basis weight. None of these except Cobb are sufficiently sensitive to evaluate light sizing, because they measure water penetration in the Z-direction and the distance is quite small. The Klemm test, which has been used for water absorptiveness of non-sized paper, determines the absorptiveness in the X-Y direction and is sufficiently sensitive to evaluate even light sizing as an absolute sizing degree. The interconnected pore structure of paper makes the absorptiveness in the X-Y direction equivalent to that in the Z-direction. The Standard Klemm test gives the absorptiveness height for 10 min testing and is independent of basis weight. A shorter testing time than 10 mm could be used but the absorptiveness height is too small to detect for heavy sizing. Further, the heading edge of water uptake is often vague, and thus the absorptiveness height can be replaced by the weight increase due to water absorption (absorptiveness weight) as a more accurate measure. Furthermore, the absorptiveness weight measured by the Klemm test which was linearly proportional to basis weight could be normalized with basis weight and specimen width (1.5 cm), and thus was indicated as absorptiveness height. This test was proposed as an absolute evaluation for sizing degree (Klemm test for sizing evaluation) in this report because it is independent of basis weight and is sensitive enough to measure sizing degree accurately even with light sizing.
引用
收藏
页码:96 / 99
页数:4
相关论文
共 50 条
  • [31] Measurement in the angiography suite: evaluation of vessel sizing techniques
    Yang, Pengfei
    Schafer, Sebastian
    Royalty, Kevin
    Ahmed, Azam
    Niemann, David
    Strother, Charles
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2016, 8 (09) : 965 - 968
  • [32] Perylene-Based Fluorescent Sizing Agent for Precise Evaluation of Permeability and Coating Property of Sizing Paste
    Jin, Enqi
    Wang, Zhengke
    Hu, Qiaoling
    Li, Manli
    Yuan, Jiugang
    ADVANCED FIBER MATERIALS, 2020, 2 (05) : 279 - 290
  • [33] Perylene-Based Fluorescent Sizing Agent for Precise Evaluation of Permeability and Coating Property of Sizing Paste
    Enqi Jin
    Zhengke Wang
    Qiaoling Hu
    Manli Li
    Jiugang Yuan
    Advanced Fiber Materials, 2020, 2 : 279 - 290
  • [34] Evaluation and sizing of a CCHP system for a commercial and office buildings
    Hanafizadeh, Pedram
    Eshraghi, Javad
    Ahmadi, Pouria
    Sattari, Amirmohammad
    JOURNAL OF BUILDING ENGINEERING, 2016, 5 : 67 - 78
  • [35] EVALUATION OF METHODS FOR SIZING AND COUNTING OF ULTRASOUND CONTRAST AGENTS
    Sennoga, Charles A.
    Yeh, James S. M.
    Alter, Julia
    Stride, Eleanor
    Nihoyannopoulos, Petros
    Seddon, John M.
    Haskard, Dorian O.
    Hajnal, Joseph V.
    Tang, Meng-Xing
    Eckersley, Robert J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (05): : 834 - 845
  • [36] EVALUATION OF PACKING DRAG ON KNIFE VALVES FOR ACTUATOR SIZING
    Garcia, Andre F.
    Veiga, Jose C.
    Romano, Luiz P.
    Girao, Carlos D.
    ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2015, VOL 2, 2015,
  • [37] EVALUATION OF A PARTICLE SIZING TECHNIQUE BASED ON LASER SHEETS
    GREHAN, G
    REN, KF
    GOUESBET, G
    NAQWI, A
    DURST, F
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 1994, 11 (01) : 101 - 106
  • [38] EVALUATION OF A NEW TYPE OF SEQUENTIAL LOT SIZING TECHNIQUES
    AXSATER, S
    SAMUELSSON, B
    ENGINEERING COSTS AND PRODUCTION ECONOMICS, 1990, 19 (1-3): : 281 - 286
  • [39] EVALUATION OF ACOUSTICAL PARTICLE COUNTER FOR THE SIZING OF FOG DROPLETS
    SINGH, DP
    REIST, PC
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 1993, 24 (01) : 35 - 44
  • [40] Studies on ASA emulsion stabilized with anionic polyvinylamine and its evaluation for sizing of different types of paper furnishes
    Kumar, Ashish
    Bhardwaj, Nishi K.
    Singh, Surendra P.
    COLLOID AND INTERFACE SCIENCE COMMUNICATIONS, 2020, 34