In situ solid-phase microextraction and post on-fiber derivatization combined with gas chromatography-mass spectrometry for determination of phenol in occupational air

被引:27
|
作者
Es-haghi, Ali [1 ]
Baghernejad, Masoud [2 ]
Bagheri, Habib [2 ]
机构
[1] Razi Vaccine & Serum Res Inst, Dept Physico Chem, Karaj, Iran
[2] Sharif Univ Technol, Dept Chem, Tehran, Iran
关键词
Phenol; Solid-phase microextraction; Sol-gel; Gas chromatography-mass spectrometry; Air sampling; Occupational air; BENZENE METABOLITES; LIQUID; HYDROQUINONE; URINE; EXTRACTION; CHEMISTRY; CATECHOL; HPLC;
D O I
10.1016/j.aca.2012.01.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method based on solid-phase microextraction (SPME) followed by on-fiber derivatization and gas chromatography-mass spectrometry detection (GC-MS) for determination of phenol in air was developed. Three different types of SPME fibers, polar and non-polar poly(dimethylsiloxane) (PDMS) and polyethylene glycol (PEG) were synthesized using sol-gel technology and their feasibility to the sampling of phenol were investigated. Different derivatization reagents for post on-fiber derivatization of phenol were studied. Important parameters influencing the extraction and derivatization process such as type of fiber coating, type and volume of derivatizing reagent. derivatization time and temperature, extraction time, and desorption conditions were investigated and optimized. The developed method is rapid, simple, easy and inexpensive and offers high sensitivity and reproducibility. Under the optimized conditions, the detection limit of the method was 5 ng L-1 using selected ion monitoring (SIM) mode. The inter-day and intra-day precisions of the developed method under optimized conditions were below 10%, and the method shows linearity in the range of 20 ng L-1 to 500 mu g L-1 with the correlation coefficient of >0.99. The optimized method was applied to the sampling of phenol from some biologics production areas. The compared results obtained using current and standard methods were shown to be satisfactory. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 50 条
  • [41] Determination of hydroxy metabolites of polycyclic aromatic hydrocarbons by fully automated solid-phase microextraction derivatization and gas chromatography-mass spectrometry
    Luan, Tiangang
    Fang, Shenghong
    Zhong, Yin
    Lin, Li
    Chan, Sidney M. N.
    Lan, Chongyu
    Tam, Nora F. Y.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1173 (1-2) : 37 - 43
  • [42] Solid-phase microextraction gas chromatography-mass spectrometry determination of fragrance allergens in baby bathwater
    Lamas, J. Pablo
    Sanchez-Prado, Lucia
    Garcia-Jares, Carmen
    Llompart, Maria
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (05) : 1399 - 1411
  • [43] Determination of diazepam in human plasma by solid-phase microextraction and capillary gas chromatography-mass spectrometry
    De Oliveira, MH
    Queiroz, MEC
    Carvalho, D
    Silva, SM
    Lanças, FM
    [J]. CHROMATOGRAPHIA, 2005, 62 (3-4) : 215 - 219
  • [44] Solid-phase microextraction gas chromatography-mass spectrometry determination of fragrance allergens in baby bathwater
    J. Pablo Lamas
    Lucia Sanchez-Prado
    Carmen Garcia-Jares
    Maria Llompart
    [J]. Analytical and Bioanalytical Chemistry, 2009, 394 : 1399 - 1411
  • [45] Determination of triazines in soil leachates by solid-phase microextraction coupled to gas chromatography-mass spectrometry
    Zambonin, CG
    Palmisano, F
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (02) : 247 - 255
  • [46] Solid-phase microextraction for the determination of cocaine and cocaethylene inhuman hair by gas chromatography-mass spectrometry
    Bermejo, AM
    López, P
    Alvarez, I
    Tabernero, MJ
    Fernández, P
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2006, 156 (01) : 2 - 8
  • [47] Solid phase microextraction combined with gas chromatography-mass spectrometry for the determination of diquat residues in water
    Lina Gao
    Guojie Liu
    Juan Zhu
    Chunyuan Wang
    Junting Liu
    [J]. Journal of Analytical Chemistry, 2015, 70 : 552 - 557
  • [48] Solid phase microextraction combined with gas chromatography-mass spectrometry for the determination of diquat residues in water
    Gao, Lina
    Liu, Guojie
    Zhu, Juan
    Wang, Chunyuan
    Liu, Junting
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) : 552 - 557
  • [49] Determination of isophorone in food samples by solid-phase microextraction coupled with gas chromatography-mass spectrometry
    Kataoka, Hiroyuki
    Terada, Yohei
    Inoue, Reiko
    Mitani, Kurie
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1155 (01) : 100 - 104
  • [50] Determination of the Volatiles in Opuntia dillenii by Headspace Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry
    Xu, Feng
    Wang, Yuanmin
    Wu, Hongmei
    Wang, Xiangpei
    [J]. INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (04) : 446 - 452