HEAT AND MASS TRANSFER ANALYSIS OF BUBBLE ABSORBERS IN AMMONIA-WATER GENERATOR-ABSORBER HEAT EXCHANGE (GAX) VAPOR ABSORPTION REFRIGERATION SYSTEM

被引:0
|
作者
Maiya, M. P. [1 ]
Mariappan, V. [2 ]
Tiwari, Shaligram [1 ]
Udayakumar, M. [2 ]
机构
[1] Indian Inst Technol, Dept Mech Engn, Refrigerat & Air Conditioning Lab, Madras 600036, Tamil Nadu, India
[2] Natl Inst Technol, Dept Mech Engn, Tiruchirappalli 620015, Tamil Nadu, India
关键词
Vapour absorption refrigeration system; Generator absorber heat exchange; Water cooled absorber; Solution cooled absorber; Bubble absorber; Plate heat exchangere; DESIGN; NH3-H2O; MODEL;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Various methods of energy recovery have been employed in vapour absorption refrigeration (VAR) systems to improve their performance and compactness. Generator absorber heat exchange (GAX) is one such method. The absorbers, namely, water cooled absorber (WCA) is the heat rejection component, solution cooled absorber (SCA) and generator cooled absorber (GCA) are the heat recovery components in the GAX-VAR system. The present work deals with the analysis of all these three absorbers which are bubble type plate heat exchangers. Mass, material and heat balance, and heat and mass transfer equations are solved to estimate number of plates required for each absorber. The importance of the work lies in attempting epsilon-NTU method for the design of absorbers, use of bubble type plate heat exchangers, simultaneous design and comparative analysis of all three absorbers.
引用
收藏
页码:1968 / +
页数:2
相关论文
共 50 条
  • [31] Mass transfer characteristics of a structured packing for ammonia rectification in ammonia-water absorption refrigeration systems
    Sieres, Jaime
    Fernandez-Seara, Jose
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01): : 58 - 67
  • [32] NUMERICAL ANALYSIS OF A NEW HEAT INTEGRATED STRUCTURE FOR VAPOR PURIFICATION OF AN AMMONIA WATER ABSORPTION REFRIGERATION SYSTEM
    Du, S.
    Wang, R. Z.
    Xia, Z. Z.
    [J]. 11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 250 - 258
  • [33] Performance characteristics of an ammonia-water absorption heat pump system
    Gadalla, Mohamed A.
    Ibrahim, Talaat A.
    Hassan, Mohamed A. M.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (14) : 1917 - 1927
  • [34] Heat and mass transfer performance analysis of a vertical tubular ammonia/water bubble absorber based on CFD modeling
    Shen, Tao
    Lu, Ding
    Liu, Zijian
    Chen, Rundong
    Gong, Maoqiong
    [J]. APPLIED THERMAL ENGINEERING, 2024, 252
  • [35] Analysis of adiabatic heat and mass transfer of microporous hydrophobic hollow fiber membrane-based generator in vapor absorption refrigeration system
    Hong, Sung Joo
    Hihara, Eiji
    Dang, Chaobin
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2018, 564 : 415 - 427
  • [36] Experimental study on impact of different ammonia vapor mass flux on ammonia-water bubble absorption process
    Wu, W. D.
    Chen, X.
    Sheng, W.
    Zhang, H.
    [J]. CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 521 - 525
  • [37] Effect of vapor flow on the falling-film heat and mass transfer of the ammonia/water absorber
    Kwon, K
    Jeong, S
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08): : 955 - 964
  • [38] HEAT AND MASS TRANSFER ACCOMPANYING THE ABSORPTION OF AMMONIA IN WATER
    HASELDEN, GG
    MALATY, SA
    [J]. CHEMISTRY & INDUSTRY, 1959, (09) : 283 - 283
  • [39] Thermodynamic analysis of an ammonia-water double absorption-resorption heat transformer system
    Jin, Pengyu
    Li, Shuhong
    Jin, Zhenghao
    Li, Yanjun
    [J]. APPLIED THERMAL ENGINEERING, 2024, 247
  • [40] Heat and mass transfer models for horizontal-tube falling-film ammonia-water absorption
    Bohra, Lalit Kumar
    Lee, Sangsoo
    Garimella, Srinivas
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2019, 107 : 84 - 97