Development and validation of liquid chromatography-mass spectrometric method for simultaneous determination of moxifloxacin and ketorolac in rat plasma: application to pharmacokinetic study

被引:23
|
作者
Raju, B. [1 ]
Ramesh, M. [1 ]
Borkar, Roshan M. [1 ,2 ]
Padiya, Raju [2 ]
Banerjee, Sanjay K. [2 ]
Srinivas, R. [1 ]
机构
[1] Indian Inst Chem Technol, Natl Ctr Mass Spectrometry, Hyderabad 500007, Andhra Pradesh, India
[2] Indian Inst Chem Technol, Div Pharmacol, Discovery Lab, Hyderabad 500007, Andhra Pradesh, India
关键词
moxifloxacin; ketorolac; LC-MS method; simultaneous determination; pharmacokinetic study; ULTRAVIOLET DETECTION; GATIFLOXACIN; LEVOFLOXACIN; ENANTIOMERS; ASSAY; SERUM;
D O I
10.1002/bmc.2701
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive, selective and rapid liquid chromatographyelectrospray ionization mass spectrometry (LC-MS) method has been developed and validated for simultaneous determination of moxifloxacin (MFX) and ketorolac (KTC) in rat plasma. Gemifloxacin (GFX) was used as an internal standard (IS). A simple protein precipitation method was used for the extraction of analytes from rat plasma. Effective chromatographic separation of MFX, KTC and GFX was achieved on a Kromasil C18 column (100?x?4.6?mm, 5?mu m) using a mobile phase consisting of acetonitrile10?mm ammonium acetate (pH 2.5)0.1% formic acid (50:25:25) in an isocratic elution, followed by detection with positive ion electrospray ionization mass spectrometry using target ions of [M?+?H]+ at m/z 402 for MFX, m/z 256 for KTC and m/z 390 for GFX in selective ion recording mode. The method was validated over the calibration range of 5100?ng/mL for MFX and 106000?ng/mL for KTC. The method demonstrated good performances in terms of intra- and inter-day precision (0.975.33%) and accuracy (93.91101.58%) for both MFX and KTC, including lower and upper limits of quantification. The recoveries from spiked control samples were >75% for MFX and >79% for KTC. The matrix effect was found to be negligible and the stability data were within acceptable limits. Further, the method was also successfully applied to a single-dose pharmacokinetic study in rats. This method can be extended to measure plasma concentrations of both drugs in human to understand drug interaction and adverse effects. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:1341 / 1347
页数:7
相关论文
共 50 条
  • [21] A rapid and sensitive liquid chromatography–tandem mass spectrometric method for the determination of hederasaponin B in rat plasma: Application to a pharmacokinetic study
    Jiaxin Liu
    Xueyan Yang
    Lin Li
    Qili Zhang
    Zhaoyan Zhang
    Xin Zhang
    Yunli Zhao
    Miao Yu
    Zhiguo Yu
    Asian Journal of Pharmaceutical Sciences, 2017, 12 (04) : 363 - 369
  • [22] Liquid chromatography-mass spectrometric method for the sensitive determination of niflumic acid in human plasma and its application to pharmacokinetic study of talniflumate tablet
    Park, Eun Ji
    Na, Dong Hee
    Shin, Young-Hee
    Lee, Kang Choon
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (02): : 159 - 162
  • [23] Liquid chromatography-tandem mass spectrometric assay for the determination of vaccarin in rat plasma: application to a pharmacokinetic study
    Yang, Guilin
    Zhang, Nan
    Wang, Tiance
    Zhang, Shudong
    Xu, Rihao
    Zhu, Zhicheng
    Liu, Kexiang
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (12) : 1789 - 1794
  • [24] Quantitative determination and pharmacokinetic study of solamargine in rat plasma by liquid chromatography-mass spectrometry
    Zheng, Xiao
    Xu, Lianming
    Liang, Yan
    Xiao, Wei
    Xie, Lin
    Zhang, Yan
    Zhao, Li
    Cao, Liang
    Chen, Jun
    Wang, Guangji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (05) : 1157 - 1162
  • [25] Quantitative determination and pharmacokinetic study of casticin in rat plasma by liquid chromatography-mass spectrometry
    Xu, Jinlong
    Zhang, Qiaoyan
    Zhao, Liang
    Wang, Ying
    Xue, Liming
    Han, Ting
    Zheng, Chengjian
    Qin, Luping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 242 - 246
  • [26] ORAL PHARMACOKINETIC STUDY OF EXEMESTANE SMEDDS AND SUSPENSION IN RAT PLASMA BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRIC ANALYSIS
    Singh, Ajeet
    Chaurasiya, Akash
    Warsi, Musarrat H.
    Chaurasiya, Manika
    Jain, Gaurav K.
    Asati, Dinesh
    Khar, Roop K.
    Mukherjee, Rama
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (15) : 2162 - 2174
  • [27] A rapid and sensitive liquid chromatography-tandem mass spectrometric method for determination of actinoside E in rat plasma and application to a pharmacokinetic study
    Qu Li-Ping
    Su Yong-Hua
    Zheng Guo-Yin
    Xin Hai-Liang
    Ling Chang-Quan
    CHINESE JOURNAL OF NATURAL MEDICINES, 2013, 11 (04) : 427 - 432
  • [28] Simultaneous determination of amlodipine and bisoprolol in rat plasma by a liquid chromatography/tandem mass spectrometry method and its application in pharmacokinetic study
    Chang, Huichao
    Li, Jinyin
    Li, Ji
    Guan, Xiaoduo
    Sun, Fanlu
    Qian, Zhongzhi
    Bi, Kaishun
    Fan, Guorong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 71 : 104 - 110
  • [29] A rapid and sensitive liquid chromatography-tandem mass spectrometric method for the determination of hederasaponin B in rat plasma: Application to a pharmacokinetic study
    Liu, Jiaxin
    Yang, Xueyan
    Li, Lin
    Zhang, Qili
    Zhang, Zhaoyan
    Zhang, Xin
    Zhao, Yunli
    Yu, Miao
    Yu, Zhiguo
    ASIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 12 (04) : 363 - 369
  • [30] Development, validation of liquid chromatography-tandem mass spectrometry method for simultaneous determination of rosuvastatin and metformin in human plasma and its application to a pharmacokinetic study
    Kumar, P. Pavan
    Murthy, T. E. G. K.
    Rao, M. V. Basaveswara
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2015, 6 (03) : 118 - 124