Optimization of ejector-expansion transcritical CO2 heat pump cycle

被引:144
|
作者
Sarkar, Jahar [1 ]
机构
[1] Banaras Hindu Univ, Dept Mech Engn, Inst Technol, Varanasi 221005, Uttar Pradesh, India
关键词
ejector-expansion CO2 cycle; modelling; entrainment ratio; pressure lift ratio; optimization; performance comparison;
D O I
10.1016/j.energy.2008.04.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
Optimization studies along with optimum parameter correlations, using constant area mixing model are presented in this article for ejector-expansion transcritical CO2 heat pump cycle with both conventional and modified layouts. Both the energetic and exergetic comparisons between valve, turbine and ejector-expansions-based transcritical CO2 heat pump cycles are also studied for simultaneous cooling and heating applications. Performances for conventional layouts are presented by maximum COP, optimum discharge pressure and corresponding entrainment ratio and pressure lift ratio of ejector, whereas for modified layout by maximum COP, optimum discharge pressure and corresponding pressure lift ratio. The optimization for modified layout can be realized for certain entrainment ratio, evaporator and gas cooler exit temperature combinations. Considering the trade-off between the system energetic and exergetic performances, and cost associated with expansion devices, the ejector may be the promising alternative expansion device for transcritical CO2 heat pump cycle. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1399 / 1406
页数:8
相关论文
共 50 条
  • [41] Optimization of Refrigerant Charge in Transcritical CO2 Heat Pump Water Heater
    He, Yu-Jia
    Liang, Xing-Yu
    Cheng, Jia-Hao
    Zhang, Chun-Lu
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (04): : 824 - 827
  • [42] Geometric parameter optimization of ejector-expansion refrigeration cycle with natural refrigerants
    Sarkar, Jahar
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (01) : 84 - 94
  • [43] Dynamic simulation on operating modes of ejector in transcritical CO2 ejector expansion refrigeration cycles
    Zheng, Lixing
    Deng, Jianqiang
    He, Yang
    Jiang, Peixue
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (01) : 15 - 29
  • [44] Performance characteristics of ejector expander transcritical CO2 refrigeration cycle
    Ersoy, H. Kursad
    Bilir, Nagihan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2012, 226 (A5) : 623 - 635
  • [45] Thermoeconomic analysis of CO2 Ejector-Expansion Refrigeration Cycle (EERC) for low-temperature refrigeration in warm climates
    Peris Perez, Bernardo
    Exposito Carrillo, Jose Antonio
    Sanchez de La Flor, Francisco Jose
    Salmeron Lissen, Jose Manuel
    Morillo Navarro, Andres
    APPLIED THERMAL ENGINEERING, 2021, 188
  • [46] Performance Analysis of Coupled System of CO2 Transcritical Heat Pump and Rankine Cycle
    Wang, Hongli
    Tian, Jingrui
    Ma, Yitai
    Hou, Xiujuan
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-4, 2011, 291-294 : 1860 - +
  • [47] Simulation of a transcritical CO2 heat pump cycle for simultaneous cooling and heating applications
    Sarkar, J.
    Bhattacharyya, Souvik
    Gopal, M. Ram
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (05): : 735 - 743
  • [48] Theoretical Study on CO2 Transcritical Cycle Combined Ejector Cycle Refrigeration System
    卢苇
    马一太
    李敏霞
    查世彤
    Transactions of Tianjin University, 2003, (04) : 316 - 320
  • [49] Advanced exergy analyses of an ejector expansion transcritical CO2 refrigeration system
    Bai, Tao
    Yu, Jianlin
    Yan, Gang
    ENERGY CONVERSION AND MANAGEMENT, 2016, 126 : 850 - 861
  • [50] Comprehensive experimental performance analyses of an ejector expansion transcritical CO2 system
    Liu, Fang
    Groll, Eckhard A.
    Ren, Jianxing
    APPLIED THERMAL ENGINEERING, 2016, 98 : 1061 - 1069