Measurement and Visualization of Doping Profile in Silicon Using Kelvin Probe Force Microscopy (KPFM)

被引:0
|
作者
Shin, Hyunjung [1 ]
Lee, Bongki [1 ]
Kim, Chanhyung [1 ]
Park, Hongsik [2 ]
Min, Dong-Ki [2 ]
Jung, Juwhan [2 ]
Hong, Seungbum [2 ]
Kim, Sungdong [3 ]
机构
[1] Kookmin Univ, Sch Adv Mat Engn, Seoul 136702, South Korea
[2] Samsung Adv Inst Technol, Storage Lab, Suwon 440600, South Korea
[3] Seoul Natl Univ Technol, Sch Mech Design & Automat Engn, Seoul 139743, South Korea
关键词
Kelvin probe force microscopy; scanning resistive probe microscopy; dopant profiles; space charge regions;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper demonstrates that Kelvin Probe Force Microscopy (KPFM) is applicable to the measurement of 2-D dopant profiles in silicon. By measuring contact potential differences, to the extent that this work-function difference is a consequence of dopant concentration at or near the sample surface, doping profiles are inferred from the measurement. Recently, scanning resistive probe microscopy (SRPM), a variant of SPM-based techniques, where a semiconductor resistor is located at the apex of the probe tip and surface charges can be observed directly, was proposed and developed. The spatial resolution of SRPM is dependent upon the size of the prepared resistor at the apex. The size of the resistor can be determined by the width (or channel) of the SiO2 implant mask, where both sides of the mask in a p-type silicon substrate were opened, implanted with As+ ions, and diffused by an activation process at 1000 degrees C for 10 to 16 hours. Using KPFM, we investigated doping profiles of the area of the resistor or, equivalently, underneath the mask. As annealing time was increased from 10 to 16 hours, shrinkage of the width (or channel) due to out-diffusion of implanted ions occurred. As a result, the contact potential difference between implanted n(+) and p (Si substrate) regions, which is equal to the resistive region, was decreased by increasing diffusion time. In conclusion, we showed that barrier height is lowered in the resisitive region, similar to a punch-through effect in a bipolar junction. It was also demonstrated that KPFM is a useful tool for measuring two-dimensional dopant profiles with nanometer spatial resolution.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 50 条
  • [41] Kelvin probe force microscopy for material characterization
    Glatzel, Thilo
    Gysin, Urs
    Meyer, Ernst
    MICROSCOPY, 2022, 71 : i165 - i173
  • [42] On the deconvolution of Kelvin probe force microscopy data
    Bluemel, A.
    Plank, H.
    Klug, A.
    Fisslthaler, E.
    Sezen, M.
    Grogger, W.
    List, E. J. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (05):
  • [43] Kelvin Probe Force Microscopy in Nonpolar Liquids
    Domanski, Anna L.
    Sengupta, Esha
    Bley, Karina
    Untch, Maria B.
    Weber, Stefan A. L.
    Landfester, Katharina
    Weiss, Clemens K.
    Butt, Hans-Juergen
    Berger, Ruediger
    LANGMUIR, 2012, 28 (39) : 13892 - 13899
  • [44] Resolution and contrast in Kelvin probe force microscopy
    Jacobs, HO
    Leuchtmann, P
    Homan, OJ
    Stemmer, A
    JOURNAL OF APPLIED PHYSICS, 1998, 84 (03) : 1168 - 1173
  • [45] Kelvin probe force microscopy study on nanotriboelectrification
    Sun, Hao
    Chu, Haibin
    Wang, Jinyong
    Ding, Lei
    Li, Yan
    APPLIED PHYSICS LETTERS, 2010, 96 (08)
  • [46] Quantitative AC - Kelvin Probe Force Microscopy
    Kohl, Dominik
    Mesquida, Patrick
    Schitter, Georg
    MICROELECTRONIC ENGINEERING, 2017, 176 : 28 - 32
  • [47] Surface potential measurement on organic ultrathin film by Kelvin probe force microscopy using a piezoelectric cantilever
    K. Kobayashi
    H. Yamada
    K. Umeda
    T. Horiuchi
    S. Watanabe
    T. Fujii
    S. Hotta
    K. Matsushige
    Applied Physics A, 2001, 72 : S97 - S100
  • [48] Local Impedance Measurement by Direct Detection of Oscillating Electrostatic Potential Using Kelvin Probe Force Microscopy
    Ishida, Nobuyuki
    JOURNAL OF PHYSICAL CHEMISTRY C, 2022, 126 (41): : 17627 - 17634
  • [49] Direct measurement of transfer functions in Kelvin probe force microscopy using artificially patterned surface potentials
    Ozasa, Kazunari
    Nemoto, Shigeyuki
    Isoshima, Takashi
    Ito, Eisuke
    Maeda, Mizuo
    Hara, Masahiko
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (07) : 5630 - 5635
  • [50] Surface potential measurement on organic ultrathin film by Kelvin probe force microscopy using a piezoelectric cantilever
    Kobayashi, K.
    Yamada, H.
    Umeda, K.
    Horiuchi, T.
    Watanabe, S.
    Fujii, T.
    Hotta, S.
    Matsushige, K.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2001, 72 (Suppl 1): : S97 - S100