Positional dependence of particles and cells in microfluidic electrical impedance flow cytometry: origin, challenges and opportunities

被引:75
|
作者
Daguerre, Hugo [1 ]
Solsona, Miguel [2 ]
Cottet, Jonathan [2 ,3 ]
Gauthier, Michael [1 ]
Renaud, Philippe [2 ]
Bolopion, Aude [1 ]
机构
[1] Univ Bourgogne Franche Comte, CNRS, FEMTO ST Inst, Dept AS2M, 24 Rue Alain Savary, F-25000 Besancon, France
[2] Ecole Polytech Fed Lausanne, EPFL STI IMT LMIS4, Stn 17, CH-1015 Lausanne, Switzerland
[3] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
基金
瑞士国家科学基金会;
关键词
DIELECTRIC-PROPERTIES; ION MOBILITY; SPECTROSCOPY; SEPARATION; ACCURACY; CONDUCTIVITY; DESIGN; ELECTROROTATION; CAPACITANCE; SUSPENSION;
D O I
10.1039/d0lc00616e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microfluidic electrical impedance flow cytometry is now a well-known and established method for single-cell analysis. Given the richness of the information provided by impedance measurements, this non-invasive and label-free approach can be used in a wide field of applications ranging from simple cell counting to disease diagnostics. One of its major limitations is the variation of the impedance signal with the position of the cell in the sensing area. Indeed, identical particles traveling along different trajectories do not result in the same data. The positional dependence can be considered as a challenge for the accuracy of microfluidic impedance cytometers. On the other hand, it has recently been regarded by several groups as an opportunity to estimate the position of particles in the microchannel and thus take a further step in the logic of integrating sensors in so-called "Lab-on-a-chip" devices. This review provides a comprehensive overview of the physical grounds of the positional dependence of impedance measurements. Then, both the developed strategies to reduce position influence in impedance-based assays and the recent reported technologies exploiting that dependence for the integration of position detection in microfluidic devices are reviewed.
引用
收藏
页码:3665 / 3689
页数:25
相关论文
共 50 条
  • [41] Continuous-flow ferrohydrodynamic sorting of particles and cells in microfluidic devices
    Zhu, Taotao
    Cheng, Rui
    Lee, Sarah A.
    Rajaraman, Eashwar
    Eiteman, Mark A.
    Querec, Troy D.
    Unger, Elizabeth R.
    Mao, Leidong
    MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (04) : 645 - 654
  • [42] Development of microfluidic flow cytometry capable of characterization of single-cell intrinsic structural and electrical parameters
    Liang, Hongyan
    Zhang, Yi
    Chen, Deyong
    Li, Yueying
    Wang, Yixiang
    Wang, Junbo
    Chen, Jian
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2022, 32 (03)
  • [43] A Continuous Flow-through Microfluidic Device for Electrical Lysis of Cells
    Lo, Ying-Jie
    Lei, U.
    MICROMACHINES, 2019, 10 (04)
  • [44] How to improve the sensitivity of coplanar electrodes and micro channel design in electrical impedance flow cytometry: a study
    Cottet, Jonathan
    Kehren, Alexandre
    van Lintel, Harald
    Buret, Francois
    Frenea-Robin, Marie
    Renaud, Philippe
    MICROFLUIDICS AND NANOFLUIDICS, 2019, 23 (01)
  • [45] How to improve the sensitivity of coplanar electrodes and micro channel design in electrical impedance flow cytometry: a study
    Jonathan Cottet
    Alexandre Kehren
    Harald van Lintel
    François Buret
    Marie Frénéa-Robin
    Philippe Renaud
    Microfluidics and Nanofluidics, 2019, 23
  • [46] Double-peak signal features in microfluidic impedance flow cytometry enable sensitive measurement of cell membrane capacitance
    Mahesh, Karthik
    Varma, Manoj
    Sen, Prosenjit
    LAB ON A CHIP, 2020, 20 (22) : 4296 - 4309
  • [47] Progress and challenges of in vivo flow cytometry and its applications in circulating cells of eyes
    Lin, Wei
    Wang, Peng
    Qi, Yingxin
    Zhao, Yanlong
    Wei, Xunbin
    CYTOMETRY PART A, 2024, 105 (06) : 437 - 445
  • [48] Developments of Conventional and Microfluidic Flow Cytometry Enabling High-Throughput Characterization of Single Cells
    Wang, Minruihong
    Liang, Hongyan
    Chen, Xiao
    Chen, Deyong
    Wang, Junbo
    Zhang, Yuan
    Chen, Jian
    BIOSENSORS-BASEL, 2022, 12 (07):
  • [49] In situ monitoring of toxic effects of algal toxin on cells by a novel microfluidic flow cytometry instrument
    Wang, Yuezhu
    Zhang, Yichi
    Wang, Junsheng
    Liu, Weibing
    Wang, Huan
    Song, Mingzhu
    Zhang, Hongyue
    Wang, Xin
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2024, 270
  • [50] Discovery of the correlation between the suspended membrane capacitance and adherent morphology of single cells enriching from clinical pleural effusion revealed by a microfluidic impedance flow cytometry
    Luan, Xiaofeng
    Li, Yuang
    Zhao, Haiping
    Sun, Sheng
    Fan, Yuanyuan
    Zhang, Wenchang
    Zhang, Lingqian
    Li, Mingxiao
    Wang, Jinghui
    Zhi, Tian
    Zhang, Lina
    Zhao, Yang
    Huang, Chengjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 371