Prediction of the body composition of pigs based on cross-sectional region analysis of dual energy x-ray absorptiometry (DXA) scans.

被引:0
|
作者
Mitchell, A
Scholz, A
Pursel, V
机构
[1] USDA ARS, Beltsville Agr Res Ctr, Beltsville Agr Res Ctr E, Growth Biol Lab, Beltsville, MD 20705 USA
[2] Univ Munich, LVG, Oberschleissheim, Germany
[3] USDA ARS, Gene Evaluat & Maping Lab, Beltsville, MD USA
来源
FASEB JOURNAL | 2002年 / 16卷 / 05期
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
引用
收藏
页码:A1024 / A1024
页数:1
相关论文
共 50 条
  • [21] Dual energy X-ray absorptiometry to predict whole body and carcass composition in pigs
    Suster, D
    Ostrowska, E
    Leury, BJ
    Wark, JD
    Kerton, DJ
    Dunshea, FR
    MANIPULATING PIG PRODUCTION VII, PROCEEDINGS, 1999, 7 : 190 - 190
  • [22] Dual-energy x-ray absorptiometry (DXA) analysis of growth and composition of pigs of different ryanodine receptor genotypes
    Mitchell, AD
    Scholz, A
    ARCHIV FUR TIERZUCHT-ARCHIVES OF ANIMAL BREEDING, 1997, 40 (01): : 47 - 56
  • [23] Body composition analysis by DXA (dual X-ray absorptiometry) in Brazilian men: normative data
    Ushida, Marcela
    Pinheiro, Marcelo de Medeiros
    de Moura Castro, Charlles Heldan
    Szejnfeld, Vera Lucia
    JOURNAL OF BONE AND MINERAL METABOLISM, 2017, 35 (05) : 554 - 561
  • [24] Body composition analysis by DXA (dual X-ray absorptiometry) in Brazilian men: normative data
    Marcela Ushida
    Marcelo de Medeiros Pinheiro
    Charlles Heldan de Moura Castro
    Vera Lucia Szejnfeld
    Journal of Bone and Mineral Metabolism, 2017, 35 : 554 - 561
  • [25] Body composition analysis of pigs from 5 to 97 kg by dual energy X-ray absorptiometry
    Mitchell, AD
    Scholz, AM
    Conway, JM
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 521 - 523
  • [26] Bone and body composition analyzed by Dual-energy X-ray Absorptiometry (DXA) in clinical and nutritional evaluation of young patients with Cystic Fibrosis: a cross-sectional study
    Lucidi, Vincenzina
    Bizzarri, Carla
    Alghisi, Federico
    Bella, Sergio
    Russo, Beatrice
    Ubertini, Graziamaria
    Cappa, Marco
    BMC PEDIATRICS, 2009, 9 : 61
  • [27] Bone and body composition analyzed by Dual-energy X-ray Absorptiometry (DXA) in clinical and nutritional evaluation of young patients with Cystic Fibrosis: a cross-sectional study
    Vincenzina Lucidi
    Carla Bizzarri
    Federico Alghisi
    Sergio Bella
    Beatrice Russo
    Graziamaria Ubertini
    Marco Cappa
    BMC Pediatrics, 9
  • [28] Optimized interpretation and reporting of dual X-ray absorptiometry (DXA) scans
    Lenchik, L
    Rochmis, P
    Sartoris, DJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (06) : 1509 - 1520
  • [29] Using Body Composition Phantoms to Validate Performance of Dual Energy X-Ray Absorptiometry (DXA) instrument
    Miller, Colin
    Yu, Hui Jing
    Horvath, Blaine
    Libber, Jessie
    Krueger, Diane
    Binkley, Neil
    JOURNAL OF BONE AND MINERAL RESEARCH, 2013, 28
  • [30] Whole and half-body dual-energy X-ray absorptiometry (DXA) analysis of body composition in obese adults
    Silverstein, W
    Stadler, D
    Peters, D
    Differding, J
    Karanja, N
    FASEB JOURNAL, 2006, 20 (04): : A165 - A165