摘要
Six base of skull IMRT treatment plans were delivered to Presage dosimeters within the RPC Head and Neck Phantom for quality assurance (QA) verification. Isotropic 2mm 3D data were acquired by optical-CT scanning with the DLOS system (Duke Large Optical-CT Scanner) and compared to the Eclipse (Varian) treatment plan. Normalized Dose Distribution (NDD) pass rates were obtained for a number of criteria. High quality 3D dosimetry data was observed from the DLOS system, illustrated here through colormaps, isodose lines, and profiles. Excellent agreement with the planned dose distributions was also observed with NDD analysis revealing > 90% pass rates (with criteria 3%, 2mm), and noise < 0.5%. The results comprehensively confirm the high accuracy of base-of-skull IMRT treatment in our clinic.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Quality assurance as Base for Mobility
    Rodriguez Conde, Maria Jose
    [J]. REDU-REVISTA DE DOCENCIA UNIVERSITARIA, 2011, 9 (03): : 99 - 117
  • [32] CE-IMRT 2 patient-based quality assurance for IMRT
    Verellen, D
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1302 - 1302
  • [33] CE-IMRT 1: Quality assurance of IMRT delivery systems - Elekta
    Sharpe, M
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1280 - 1280
  • [34] CE-IMRT 1: Quality assurance of IMRT delivery systems - Varian
    LoSasso, T
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1279 - 1280
  • [35] Skull Base Osteomyelitis: A Comprehensive Imaging Review
    Chapman, P. R.
    Choudhary, G.
    Singhal, A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (03) : 404 - 413
  • [36] Application of statistical process control to IMRT quality assurance
    Fang, B.
    Shoale, J.
    Pawlicki, T.
    Boyer, A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2071 - 2071
  • [37] A quality assurance program for micro-multileaf IMRT
    Solberg, T
    Agazaryan, N
    DeMarco, J
    Promberger, C
    Ullrich, W
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1268 - 1268
  • [38] An analysis of tolerance levels in IMRT quality assurance procedures
    Basran, Parminder S.
    Woo, Milton K.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2300 - 2307
  • [39] A planar dose calculation algorithm for IMRT quality assurance
    Yan, G.
    Liu, C.
    Lu, B.
    Palta, J.
    Li, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2059 - 2059
  • [40] A versatile, efficient, and inexpensive phantom for IMRT quality assurance
    Urie, MM
    Lo, YC
    [J]. RADIOLOGY, 2001, 221 : 166 - 167