Breath-hold CT attenuation correction for quantitative cardiac SPECT

被引:10
|
作者
Koshino, Kazuhiro [1 ]
Fukushima, Kazuhito [2 ]
Fukumoto, Masaji [2 ]
Sasaki, Kazunari [3 ]
Moriguchi, Tetsuaki [1 ]
Hori, Yuki [1 ]
Zeniya, Tsutomu [1 ]
Nishimura, Yoshihiro [2 ]
Kiso, Keisuke [2 ]
Iida, Hidehiro [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Res Inst, Dept Investigat Radiol, Suita, Osaka 5658565, Japan
[2] Natl Cerebral & Cardiovasc Ctr Hosp, Dept Radiol & Nucl Med, Suita, Osaka 5658565, Japan
[3] Osaka Univ, Fac Med, Grad Sch Med, Suita, Osaka 5650871, Japan
来源
EJNMMI RESEARCH | 2012年 / 2卷
关键词
Single Photon Emission Compute Tomography; Myocardial Blood Flow; Single Photon Emission Compute Tomography Image; Radioactivity Concentration; Compute Tomography Attenuation;
D O I
10.1186/2191-219X-2-33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Attenuation correction of a single photon emission computed tomography (SPECT) image is possible using computed tomography (CT)-based attenuation maps with hybrid SPECT/CT. CT attenuation maps acquired during breath holding can be misaligned with SPECT, generating artifacts in the reconstructed images. The purpose of this study was to investigate the effects of respiratory phase during breath-hold CT acquisition on attenuation correction of cardiac SPECT imaging. Methods: A series of 201Tl-emission and 99mTc-based transmission computed tomography (TCT) scans was carried out along with CT-attenuation scans on 11 young normal volunteers using a hybrid SPECT/CT scanner. The CT scans were performed at three respiratory phases: end-inspiration (INS), end-expiration (EXP), and the midpoint (MID) between these phases. Using alignment parameters between attenuation maps and SPECT images without attenuation or scatter corrections, quantitative SPECT images were reconstructed, including corrections for attenuation and scatter. Regional radioactivity concentrations normalized by the subjects' weights were compared between CT-and TCT-based attenuation correction techniques. Results: SPECT images with CT attenuation maps at the EXP phase showed significant differences in regional weight-normalized radioactivity concentrations relative to the images using the other attenuation maps (p< 0.05), as well as systematic positive bias errors, compared to TCT-based images for all myocardial segments, 5.7% +/- 2.7% (1.9% to 10.0%). No significant differences in regional weight-normalized radioactivity concentrations were observed between images with CT attenuation maps at MID and INS phases or between these and the TCT-based images, but regional tendencies were found: for anterior to anterolateral segment, positive bias of 5.0% +/- 2.2% (1.3% to 8.1%) and 5.6% +/- 1.9% (2.6% to 8.5%) and for inferior to inferoseptal segment, negative bias of -5.3% +/- 2.6% (-9.1% to -1.7%) and -4.6% +/- 2.5% (-8.8% to -1.5%) for the MID and INS phases, respectively. Conclusions: Use of breath-hold CT attenuation maps at INS and MID phases for attenuation and scatter corrections demonstrated accurate quantitative images that would prove beneficial in cardiac SPECT/CT studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Clinical application of deep-inspiratory breath-hold pulmonary perfusion SPECT with SPECT-CT combined system in patients with pulmonary thromboembolism
    Fukushima, Y.
    Kumita, S.
    Kobayashi, Y.
    Sugihara, Y.
    Tomiyama, T.
    Kiriyama, T.
    Sohara, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S386 - S386
  • [42] Towards validation of breath-hold ventilation CT for NSCLC radiotherapy planning
    Tahir, B. A.
    Swinscoe, J. A.
    Hatton, M. Q.
    Wild, J. M.
    Ireland, R. H.
    LUNG CANCER, 2014, 83 : S58 - S58
  • [43] Detectability of hepatocellular carcinoma by breath-hold MR imaging and spiral CT
    Kurata, T
    Tanimoto, A
    Yuasa, Y
    Kobayashi, S
    Fujiwara, H
    Hiramatsu, K
    RADIOLOGY, 1999, 213P : 426 - 426
  • [44] Clinical application of breath-hold PET/CT to improve quantitation of the NSCLC
    Huang, W.
    Tasi, S.
    Pan, T.
    Tseng, J.
    Lin, K.
    Yen, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S837 - S837
  • [45] Cardiac function during breath-hold diving in humans: An echocardiographic study
    Marabotti, C.
    Belardinelli, A.
    L'abbate, A.
    Scalzini, A.
    Chiesa, F.
    Cialoni, D.
    Passera, M.
    Bedini, R.
    UNDERSEA & HYPERBARIC MEDICINE, 2008, 35 (02): : 83 - 90
  • [46] On-board breath-hold digital tomosynthesis (DTS) for target localization prior to breath-hold treatment
    Godfrey, D. J.
    Wang, Z.
    Yoo, S.
    Wu, J.
    Oldham, M.
    Willett, C.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S613 - S614
  • [47] Impact of Breath-Hold Level but Not Variation on Positional Shift in Hepatobiliary Radiotherapy with Breath-Hold Respiratory Control
    Tien, Y.
    Huang, A.
    Wu, J. K.
    Cheng, J. C. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E221 - E221
  • [48] Effect of a motion correction algorithm on malignant lung nodule uptake: in comparison to ordinary and breath-hold PET/CT
    Jreige, M.
    Gnesin, S.
    Schleyer, P.
    Conti, M.
    Prior, J. O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S415 - S416
  • [49] Single CT for attenuation correction of rest/stress cardiac SPECT perfusion imaging
    Wells, R. Glenn
    Trottier, Mikael
    Premaratne, Manuja
    Vanderwerf, Karen
    Ruddy, Terrence D.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (02) : 616 - 624
  • [50] INTER-STUDY REPRODUCIBILITY OF STRAIN MEASURMENTS BY CARDIAC MRI: A COMPARISON OF FEATURE TRACKING, SINGLE BREATH-HOLD TAGGING AND MULTI BREATH-HOLD TAGGING
    Singh, A.
    Steadman, C. D.
    Khan, J. N.
    Nazir, S. A.
    McCann, G. P.
    HEART, 2013, 99