Breath-hold CT attenuation correction for quantitative cardiac SPECT

被引:10
|
作者
Koshino, Kazuhiro [1 ]
Fukushima, Kazuhito [2 ]
Fukumoto, Masaji [2 ]
Sasaki, Kazunari [3 ]
Moriguchi, Tetsuaki [1 ]
Hori, Yuki [1 ]
Zeniya, Tsutomu [1 ]
Nishimura, Yoshihiro [2 ]
Kiso, Keisuke [2 ]
Iida, Hidehiro [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Res Inst, Dept Investigat Radiol, Suita, Osaka 5658565, Japan
[2] Natl Cerebral & Cardiovasc Ctr Hosp, Dept Radiol & Nucl Med, Suita, Osaka 5658565, Japan
[3] Osaka Univ, Fac Med, Grad Sch Med, Suita, Osaka 5650871, Japan
来源
EJNMMI RESEARCH | 2012年 / 2卷
关键词
Single Photon Emission Compute Tomography; Myocardial Blood Flow; Single Photon Emission Compute Tomography Image; Radioactivity Concentration; Compute Tomography Attenuation;
D O I
10.1186/2191-219X-2-33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Attenuation correction of a single photon emission computed tomography (SPECT) image is possible using computed tomography (CT)-based attenuation maps with hybrid SPECT/CT. CT attenuation maps acquired during breath holding can be misaligned with SPECT, generating artifacts in the reconstructed images. The purpose of this study was to investigate the effects of respiratory phase during breath-hold CT acquisition on attenuation correction of cardiac SPECT imaging. Methods: A series of 201Tl-emission and 99mTc-based transmission computed tomography (TCT) scans was carried out along with CT-attenuation scans on 11 young normal volunteers using a hybrid SPECT/CT scanner. The CT scans were performed at three respiratory phases: end-inspiration (INS), end-expiration (EXP), and the midpoint (MID) between these phases. Using alignment parameters between attenuation maps and SPECT images without attenuation or scatter corrections, quantitative SPECT images were reconstructed, including corrections for attenuation and scatter. Regional radioactivity concentrations normalized by the subjects' weights were compared between CT-and TCT-based attenuation correction techniques. Results: SPECT images with CT attenuation maps at the EXP phase showed significant differences in regional weight-normalized radioactivity concentrations relative to the images using the other attenuation maps (p< 0.05), as well as systematic positive bias errors, compared to TCT-based images for all myocardial segments, 5.7% +/- 2.7% (1.9% to 10.0%). No significant differences in regional weight-normalized radioactivity concentrations were observed between images with CT attenuation maps at MID and INS phases or between these and the TCT-based images, but regional tendencies were found: for anterior to anterolateral segment, positive bias of 5.0% +/- 2.2% (1.3% to 8.1%) and 5.6% +/- 1.9% (2.6% to 8.5%) and for inferior to inferoseptal segment, negative bias of -5.3% +/- 2.6% (-9.1% to -1.7%) and -4.6% +/- 2.5% (-8.8% to -1.5%) for the MID and INS phases, respectively. Conclusions: Use of breath-hold CT attenuation maps at INS and MID phases for attenuation and scatter corrections demonstrated accurate quantitative images that would prove beneficial in cardiac SPECT/CT studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Breath-hold CT attenuation correction for quantitative cardiac SPECT
    Kazuhiro Koshino
    Kazuhito Fukushima
    Masaji Fukumoto
    Kazunari Sasaki
    Tetsuaki Moriguchi
    Yuki Hori
    Tsutomu Zeniya
    Yoshihiro Nishimura
    Keisuke Kiso
    Hidehiro Iida
    EJNMMI Research, 2
  • [2] Attenuation correction of emission PET images with average CT: Interpolation from breath-hold CT
    Huang, Tzung-Chi
    Zhang, Geoffrey
    Chen, Chih-Hao
    Yang, Bang-Hung
    Wu, Nien-Yun
    Wang, Shyh-Jen
    Wu, Tung-Hsin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S156 - S158
  • [3] Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT
    Suga, K.
    Yasuhiko, K.
    Iwanaga, H.
    Tokuda, O.
    Matsunaga, N.
    ACTA RADIOLOGICA, 2009, 50 (01) : 34 - 41
  • [4] Automated breath-hold perfusion SPECT/CT fusion images of the lungs
    Suga, Kazuyoshi
    Kawakami, Yasuhiko
    Iwanaga, Hideyuki
    Tokuda, Osamu
    Matsunaga, Naofumi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) : 455 - 463
  • [5] Combined CT and SPECT deep inspiration breath-hold acquisition in myocardial imaging
    Clerc, Olivier
    Buechel, Ronny
    Fuchs, Tobias
    Possner, Mathias
    Svetlana, Dougoud
    Stehli, Julia
    Kaufmann, Philipp
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [6] Clinical significance of CT density-based, non-uniform photon attenuation correction of deep-inspiratory breath-hold perfusion SPECT
    Suga, Kazuyoshi
    Okada, Munemasa
    Kunihiro, Mitsue
    Iwanaga, Hideyuki
    Matsunaga, Naofumi
    ANNALS OF NUCLEAR MEDICINE, 2011, 25 (04) : 289 - 298
  • [7] Clinical significance of CT density-based, non-uniform photon attenuation correction of deep-inspiratory breath-hold perfusion SPECT
    Kazuyoshi Suga
    Munemasa Okada
    Mitsue Kunihiro
    Hideyuki Iwanaga
    Naofumi Matsunaga
    Annals of Nuclear Medicine, 2011, 25 : 289 - 298
  • [8] Findings of hepatopulmonary syndrome on breath-hold perfusion SPECT-CT fusion images
    Suga, Kazuyoshi
    Kawakami, Yasuhiko
    Iwanaga, Hideyuki
    Tokuda, Osamu
    Matsunaga, Naofumi
    ANNALS OF NUCLEAR MEDICINE, 2009, 23 (04) : 413 - 419
  • [9] Findings of hepatopulmonary syndrome on breath-hold perfusion SPECT-CT fusion images
    Kazuyoshi Suga
    Yasuhiko Kawakami
    Hideyuki Iwanaga
    Osamu Tokuda
    Naofumi Matsunaga
    Annals of Nuclear Medicine, 2009, 23 : 413 - 419
  • [10] Comprehensive assessment of lung CT attenuation alteration at perfusion defects of acute pulmonary thromboembolism with breath-hold SPECT-CT fusion images
    Suga, K
    Kawakami, Y
    Iwanaga, H
    Hayashi, N
    Seto, A
    Matsunaga, N
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (01) : 83 - 91