Bioactive glass as bone-graft substitute for posterior spinal fusion in rabbit

被引:13
|
作者
Lindfors, NC
Tallroth, K
Aho, AJ
机构
[1] Turku Univ, Biomat Project Turku, Turku 20520, Finland
[2] Orton Res Inst, Invalid Fdn, Helsinki 00280, Finland
[3] Univ Turku, Cent Hosp, Dept Surg, FIN-20520 Turku, Finland
来源
关键词
bioactive glass; spinal fusion; biomaterial; autograft bone; bone substitute;
D O I
10.1002/jbm.10177
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bioactive glass S53P4 and autogenous bone were studied as bone graft materials for spinal fusion in a rabbit model. Sixteen rabbits underwent surgery by a dorsal approach. A bioactive glass, a combination of bioactive glass and autogenous bone (70/30 vol%), and autogenous bone were implanted at two thoracolumbar vertebraes for 4 and 12 weeks. The volume, consolidation to vertebrae, and fusion of the graft material were evaluated with plain-film radiology, computed tomography (CT) and bone-mineral density measurements, and compared with histomorphometrical measurements. Radiological consolidation by CT of bone graft to underlying vertebrae at 12 weeks was observable in all groups. This was histologically confirmed as bone was growing from the vertebrae into the graft material. Radiologic fusion of vertebraes was, at 12 weeks, observable in all groups in 50-75% of the cases. The radiologic fusion seen at the CT scans could, however, not be confirmed by histology in any of the three groups. Significant differences for graft material and observation period with the use of bone-mineral density measurements (Hounsfield units) were also observable, with the highest measured values for the bioactive glass group and the lowest for the autogenous bone group. The results indicate that bioactive glass have potential as bone-graft material in spinal fusion. The reliability of radiologic evaluation methods in spinal surgery using bone substitutes is also questioned and discussed. (C) 2002 John Wiley Sons, Inc.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [41] POSTERIOR CERVICAL ARTHRODESIS WITH AO RECONSTRUCTION PLATES AND BONE-GRAFT
    ANDERSON, PA
    HENLEY, MB
    GRADY, MS
    MONTESANO, PX
    WINN, HR
    SPINE, 1991, 16 (03) : S72 - S79
  • [42] Bioactive glass S53P4 as bone graft substitute in treatment of osteomyelitis
    Lindfors, N. C.
    Hyvonen, P.
    Nyyssonen, M.
    Kirjavainen, M.
    Kankare, J.
    Gullichsen, E.
    Salo, J.
    BONE, 2010, 47 (02) : 212 - 218
  • [43] ENHANCEMENT OF ANGIOGENESIS BY BFGF IN MANDIBULAR BONE-GRAFT HEALING IN THE RABBIT
    EPPLEY, BL
    DOUCET, M
    CONNOLLY, DT
    FEDER, J
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 46 (05) : 391 - 398
  • [44] PREFORMED AUTOLOGOUS BONE-GRAFT - EXPERIMENTAL-STUDY IN THE RABBIT
    ALBREKTSSON, T
    BRANEMARK, PI
    ERIKSSON, A
    LINDSTROM, J
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1978, 12 (03): : 215 - 223
  • [45] PULVERIZED BONE-MATRIX AS AN INJECTABLE BONE-GRAFT IN RABBIT RADIUS DEFECTS
    ASPENBERG, P
    WITTBJER, J
    THORNGREN, KG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (206) : 261 - 269
  • [46] EXTRUSION OF BONE-GRAFT AFTER LUMBAR FUSION - CT APPEARANCE
    COUGHLAN, JD
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (03) : 399 - 400
  • [47] POROUS HYDROXYLAPATITE AS A BONE-GRAFT SUBSTITUTE IN MANDIBULAR CONTOUR AUGMENTATION - A HISTOMETRIC STUDY
    HOLMES, RE
    HAGLER, HK
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (05) : 421 - 429
  • [48] Impaction grafting with a bone-graft substitute in a sheep model of revision hip replacement
    Coathup, M.
    Smith, N.
    Kingsley, C.
    Buckland, T.
    Dattani, R.
    Ascroft, P.
    Blumn, G.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (02): : 246 - 253
  • [49] POROUS HYDROXYAPATITE AS A BONE-GRAFT SUBSTITUTE IN ALVEOLAR RIDGE AUGMENTATION - A HISTOMETRIC STUDY
    HOLMES, RE
    ROSER, SM
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 16 (06) : 718 - 728
  • [50] Monitoring the Setting of Calcium Sulfate Bone-Graft Substitute Using Ultrasonic Backscattering
    Rodriguez-Sendra, Josep
    Jimenez, Noe
    Pico, Ruben
    Faus, Joan
    Camarena, Francisco
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (10) : 1658 - 1666