Acute Kidney Injury Following Tricuspid Transcatheter Edge-to-Edge Repair

被引:7
|
作者
Tanaka, Tetsu [1 ]
Kavsur, Refik [1 ]
Sugiura, Atsushi [1 ]
Haurand, Jean Marc [2 ]
Galka, Natalia [1 ]
Oeztuerk, Can [1 ]
Vogelhuber, Johanna [1 ]
Becher, Marc Ulrich [1 ]
Weber, Marcel [1 ]
Westenfeld, Ralf [2 ]
Zimmer, Sebastian [1 ]
Kelm, Malte [2 ]
Nickenig, Georg [1 ]
Horn, Patrick [2 ]
Zachoval, Christian [1 ]
机构
[1] Univ Hosp Bonn, Heart Ctr Bonn, Dept Internal Med 2, Bonn, Germany
[2] Heinrich Heine Univ, Dept Cardiol Pulmonol & Vasc Med, Med Fac, Dusseldorf, Germany
关键词
  acute kidney injury; tricuspid regurgitation; tricuspid transcatheter edge-to-edge repair; MITRAL-VALVE REPAIR; REGURGITATION; MULTICENTER; OUTCOMES; SYSTEM;
D O I
10.1016/j.jcin.2022.07.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Little is known about the incidence and clinical relevance of postprocedural acute kidney injury (AKI) in patients undergoing transcatheter edge-to-edge repair (TEER) for tricuspid regurgitation (TR).OBJECTIVES The aim of this study was to investigate the prognostic impact of postprocedural AKI following TEER for TR.METHODS Two hundred sixty-eight patients who underwent TEER for TR at 2 centers were retrospectively analyzed. Postprocedural AKI was defined as an increase in serum creatinine of >= 0.3 mg/dL within 48 hours or >= 50% within 7 days after the procedure compared with baseline. The association between AKI and the composite outcome, consisting of all-cause mortality and rehospitalization for heart failure within 1 year after the procedure, was determined.RESULTS The mean age of the patients was 79.0 +/- 6.8 years, and 43.3% were men. Postprocedural AKI occurred in 42 patients (15.7%). Age, male sex, an estimated glomerular filtration rate of <60 mL/min/1.73 m2, and absence of procedural success were associated with the occurrence of AKI. Patients with AKI had a higher incidence of in-hospital mortality than those without AKI (9.5% vs 0.9%; P = 0.006). Moreover, AKI was associated with the incidence of the composite outcome within 1 year after TEER for TR (adjusted HR: 2.39; 95% CI: 1.45-3.94; P = 0.001).CONCLUSIONS Postprocedural AKI occurred in 15.7% of patients undergoing TEER for TR, despite the absence of iodinated contrast agents, which was associated with worse clinical outcomes. These findings highlight the clinical impact of AKI following TEER for TR and should help in identifying patients at high risk for AKI. (J Am Coll Cardiol Intv 2022;15:1936-1945)(c) 2022 by the American College of Cardiology Foundation.
引用
收藏
页码:1936 / 1945
页数:10
相关论文
共 50 条
  • [31] Characteristics and Outcomes of Patients Ineligible for Tricuspid Transcatheter Edge-to-Edge Repair
    Hatab, Taha
    Chaaya, Rody G. Bou
    Samimi, Sahar
    Qamar, Fatima
    Faza, Nadeen
    Little, Stephen H.
    Reardon, Michael J.
    Kleiman, Neal S.
    Zoghbi, William A.
    Guha, Ashrith
    Zaid, Syed
    Goel, Sachin S.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2024, 8 (02):
  • [32] Key Echocardiographic Considerations for Tricuspid Valve Transcatheter Edge-to-Edge Repair
    Hungerford, Sara L.
    Rye, Eleanor E.
    Hansen, Peter S.
    Bhindi, Ravinay
    Choong, Christopher
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2023, 36 (04) : 366 - +
  • [33] Clinical outcomes following tricuspid transcatheter edge-to-edge repair with PASCAL: A meta-analysis
    Badwan, Osamah
    Mirzai, Saeid
    Skoza, Warren
    Hawk, Fahad
    Braghieri, Lorenzo
    Persits, Ian
    Krishnaswamy, Amar
    Puri, Rishi
    Kapadia, Samir R.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 389
  • [34] Imaging for Transcatheter Edge-to-Edge Repair for Tricuspid Regurgitation in Ebstein Anomaly
    Fan, Yiting
    Kam, Kevin
    So, Kent
    Lam, Yat-Yin
    Lee, Alex Pui-Wai
    CIRCULATION-CARDIOVASCULAR IMAGING, 2021, 14 (11) : e013327
  • [35] Transcatheter tricuspid valve edge-to-edge repair for severe tricuspid regurgitation in a Chinese patient
    Cheung, Gary S. H.
    Kam, Kevin K. H.
    Lam, Yat-Yin
    Lee, Alex P. W.
    HEART ASIA, 2018, 10 (01)
  • [36] Leaflet Configuration and Residual Tricuspid Regurgitation After Transcatheter Edge-to-Edge Tricuspid Repair
    Sugiura, Atsushi
    Tanaka, Tetsu
    Kavsur, Refik
    Ozturk, Can
    Vogelhuber, Johanna
    Wilde, Nihal
    Becher, Marc Ulrich
    Zimmer, Sebastian
    Nickenig, Georg
    Weber, Marcel
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (20) : 2260 - 2270
  • [37] Acute Kidney Injury After Percutaneous Edge-to-Edge Mitral Repair
    Armijo, German
    Estevez-Loureiro, Rodrigo
    Carrasco-Chinchilla, Fernando
    Arzamendi, Dabit
    Fernandez-Vazquez, Felipe
    Jimenez-Quevedo, Pilar
    Freixa, Xavier
    Pascual, Isaac
    Serrador, Ana Maria
    Mesa, Dolores
    Alonso-Briales, Juan H.
    Goicolea, Javier
    Hernandez-Antolin, Rosana
    Fernandez-Peregrina, Estefania
    Alvarez, Ana Belen Cid
    Andraka, Leire
    Cruz-Gonzalez, Ignacio
    Berenguer, Alberto
    Sanchis, Juan
    Gil, Jose Luis Diez
    Hernandez-Garcia, Jose M.
    Li, Chi-Hion
    Benito-Gonzalez, Tomas
    de Agustin, Jose A.
    Avanzas, Pablo
    Regueiro, Ander
    Amat-Santos, Ignacio
    Pan, Manuel
    Nombela-Franco, Luis
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (21) : 2463 - 2473
  • [38] Real-World Experience in Tricuspid Transcatheter Edge-to-Edge Repair: Transcatheter Tricuspid Valve Repair in Spain Registry
    Sisinni, Antonio
    Barreiro-Perez, Manuel
    Freixa, Xavier
    Arzamendi, Dabit
    Monivas, Vanessa
    Carrasco-Chinchilla, Fernando
    Pan, Manuel
    Nombela-Franco, Luis
    Pascual, Isaac
    Benito-Gonzalez, Tomas
    Perez, Ruth
    Gomez-Blazquez, Ivan
    Amat-Santos, Ignacio J.
    Cruz-Gonzalez, Ignacio
    Sanchez-Recalde, Angel
    Alvarez, Ana Belen Cid
    Sanchis, Laura
    Caneiro-Queija, Berenice
    Li, Chi Hion
    del Trigo, Maria
    Martinez-Carmona, Jose David
    Mesa, Dolores
    Pozo, Eduardo
    Avanzas, Pablo
    Cepas-Guillen, Pedro
    Estevez-Loureiro, Rodrigo
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2025, 14 (02):
  • [39] Acute Kidney Injury After "Zero Contrast" Tricuspid Edge-to-Edge Repair More Than a Procedural Complication?
    Chevalier, Bernard
    Neylon, Antoinette
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (19) : 1946 - 1947
  • [40] Improvement of endorgan function following tricuspid edge-to-edge repair
    Jorde, U.
    Benza, R.
    Whisenant, B.
    Makkar, R.
    Tadros, P.
    Naik, H.
    Fam, N.
    Sauer, A.
    Murthy, S.
    Kar, S.
    Von Bardeleben, R.
    Hahn, R.
    Hamid, N.
    Adams, D.
    Sorajja, P.
    EUROPEAN HEART JOURNAL, 2024, 45