Modeling of the human circulatory system with an axial flow ventricular assist device

被引:0
|
作者
Giridharan, GA [1 ]
Skliar, M [1 ]
机构
[1] Univ Utah, Dept Chem & Fuels Engn, Salt Lake City, UT 84112 USA
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents an integrated state space model of human circulatory system with a brushless DC axial flow left ventricular assist device (VAD). The developed integrated model combines a network type hybrid model of the circulatory system with the nonlinear dynamic model of the brushless DC pump. The model, though simple, preserves essential characteristics such as non-linearity, pulsativity and discontinuity due to the effects of the heart valves and the pump dynamics. Computer simulations of the circulatory system for different pathological conditions ranging from the normal heart to left heart asystole and physical scenarios ranging from rest to exercise were used to validate the accuracy and adaptability of the model. A simple PI controller was designed for the VAD, that adequately increased the cardiac demand for widely varying pathological conditions.
引用
收藏
页码:3801 / 3806
页数:6
相关论文
共 50 条
  • [21] Improved flow straighteners reduce thrombus in the NASA/DeBakey axial flow ventricular assist device
    Kawahito, K
    Benkowski, R
    Ohtsubo, S
    Noon, GP
    Nose, Y
    DeBakey, ME
    ARTIFICIAL ORGANS, 1997, 21 (04) : 339 - 343
  • [22] Development of the Nimbus/Pittsburgh axial flow left ventricular assist system
    Butler, K
    Thomas, D
    Antaki, J
    Borovetz, H
    Griffith, B
    Kameneva, M
    Kormos, R
    Litwak, P
    ARTIFICIAL ORGANS, 1997, 21 (07) : 602 - 610
  • [23] AN IMPLANTABLE SYSTEM FOR PRODUCING LEFT VENTRICULAR FAILURE FOR CIRCULATORY-ASSIST DEVICE EVALUATION
    JOISON, J
    KUMAR, R
    HOOD, WB
    NORMAN, JC
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1969, 15 : 417 - &
  • [24] Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System
    Bozkurt, Selim
    van de Vosse, Frans N.
    Rutten, Marcel C. M.
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (03) : 308 - 315
  • [25] Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System
    Selim Bozkurt
    Frans N. van de Vosse
    Marcel C. M. Rutten
    Journal of Medical and Biological Engineering, 2016, 36 : 308 - 315
  • [26] Axial Flow Left Ventricular Assist Device is Associated with Progression of Aortic Valve Insufficiency
    Masood, M. F.
    Fischer, I.
    Kotkar, K.
    Ewald, G. A.
    Silvestry, S. C.
    Balsara, K. R.
    Itoh, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S284 - S285
  • [27] Intermediate experience with the Jarvik 2000 axial flow left ventricular assist device (LVAD)
    Haj-Yahya, S. M.
    Birks, E. J.
    Hardy, J.
    Hipkin, M.
    Bowles, C.
    Dreyfus, G.
    Banner, N.
    Khaghani, A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02): : S58 - S58
  • [28] Mitral Regurgitation and Axial Flow Left Ventricular Assist Device: A Computer Simulation Study
    Jelenc, Matija
    Jelenc, Blaz
    Vrtovec, Bojan
    Knezevic, Ivan
    ASAIO JOURNAL, 2013, 59 (04) : 405 - 409
  • [29] Extended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist Device
    Pagani, Francis D.
    Miller, Leslie W.
    Russell, Stuart D.
    Aaronson, Keith D.
    John, Ranjit
    Boyle, Andrew J.
    Conte, John V.
    Bogaev, Roberta C.
    MacGillivray, Thomas E.
    Naka, Yoshifumi
    Mancini, Donna
    Massey, H. Todd
    Chen, Leway
    Klodell, Charles T.
    Aranda, Juan M.
    Moazami, Nader
    Ewald, Gregory A.
    Farrar, David J.
    Frazier, O. Howard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (04) : 312 - 321
  • [30] Acquired von Willebrand Syndrome in Patients With an Axial Flow Left Ventricular Assist Device
    Meyer, Anna L.
    Malehsa, Doris
    Bara, Christoph
    Budde, Ulrich
    Slaughter, Mark S.
    Haverich, Axel
    Strueber, Martin
    CIRCULATION-HEART FAILURE, 2010, 3 (06) : 675 - 681