MRI comparison of quantitative left ventricular structure, function and measurement reproducibility in patient cohorts with a range of clinically distinct cardiac conditions

被引:7
|
作者
Gandy, Stephen J. [1 ,2 ]
Waugh, Shelley A. [1 ,2 ]
Nicholas, R. Stephen [1 ,2 ]
Rajendra, Narasimharaj [3 ]
Martin, Patricia [2 ]
Houston, J. Graeme [2 ]
机构
[1] Ninewells Hosp, Dept Med Phys, NHS Tayside, Dundee DD1 9SY, Scotland
[2] Ninewells Hosp, Dept Clin Radiol, NHS Tayside, Dundee DD1 9SY, Scotland
[3] Univ Dundee, Sch Med, Ninewells Hosp, Dundee DD1 9SY, Scotland
来源
关键词
magnetic resonance imaging; left ventricular ejection fraction; left ventricular mass; repeatability; patient volunteers;
D O I
10.1007/s10554-008-9293-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Quantitative MRI assessments of cardiac structure and function are possible and potentially useful for longitudinal clinical monitoring. The aim of this study was to compare the magnitude and repeatability of left ventricular (LV) ejection fraction (EF) and mass (LVM) measurements in patients with clinically distinct cardiac conditions. Materials and Methods Patients were recruited into four groups: (i) congestive heart failure (CHF), (ii) left ventricular hypertrophy (LVH), (iii) recent post myocardial infarct (PMI), and (iv) healthy normal volunteers (HNV). LV short-axis images were acquired on a 1.5T MRI scanner and analysed on a satellite workstation. EF and LVM (at ED) values were derived from myocardial segmentations, and intra- observer test-retest coefficients of repeatability (CoR) were determined for each cohort. Results The mean EF for the CHF patients (30.3%) was lower than for the other cohorts (LVH 72.7%, PMI 53.0%, HNV 67.0%; P < 0.0002). As expected, the mean LVM for the CHF patients (143 g) was greater than for the other cohorts (LVH 122 g, PMI 124 g, HNV 107 g), but only significant when compared to the HNV cohort (P = 0.004). The intra-observer CoR values for EF were 1.5% (LVH), 1.6% (HNV), 2.6% (PMI) and 5.5% (CHF), and 4.6 g (HNV), 6.7 g (PMI), 8.3 g (CHF) and 9.8 g (LVH) for LVM. Conclusion The EF, LVM and associated repeatability parameters are variable and dependent upon the clinical condition under investigation. It is important that reproducibility data for EF and LVM are acquired individually and specifically on a per-cohort basis if the parameters are to form reliable endpoints for longitudinal clinical follow-up assessments.
引用
收藏
页码:627 / 632
页数:6
相关论文
共 39 条
  • [31] QUANTIFICATION OF LEFT VENTRICULAR SIZE AND FUNCTION USING CONTRAST-ENHANCED REAL-TIME 3D IMAGING WITH POWER MODULATION: COMPARISON WITH CARDIAC MRI
    Coon, Patrick D.
    Pollard, Heidi
    Furlong, Kathleen
    Lang, Roberto M.
    Mor-Avi, Victor
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (11): : 1853 - 1858
  • [32] Quantitative Assessment of Cardiac Output and Left Ventricular Function by Noninvasive Phase-Contrast and Cine MRI: Validation Study With Invasive Pressure-Volume Loop Analysis in a Swine Model
    Lin, Hung-Yu
    Freed, Darren
    Lee, Trevor W. R.
    Arora, Rakesh C.
    Ali, Ayyaz
    Almoustadi, Waiel
    Xiang, Bo
    Wang, Fei
    Large, Stephen
    King, Scott B.
    Tomanek, Boguslaw
    Tian, Ganghong
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (01) : 203 - 210
  • [33] Quantification of left and right ventricular function and myocardial mass: Comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRI
    Takx, Richard A. P.
    Moscariello, Antonio
    Schoepf, U. Joseph
    Barraza, J. Michael, Jr.
    Nance, John W., Jr.
    Bastarrika, Gorka
    Das, Marco
    Meyer, Mathias
    Wildberger, Joachim E.
    Schoenberg, Stefan O.
    Fink, Christian
    Henzler, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E598 - E604
  • [34] Multi-slice CT (MSCT) in cardiac function imaging: Threshold-value-supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI
    Ehrhard, K
    Oberholzer, K
    Gast, K
    Mildenberger, P
    Kreitner, KF
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (12): : 1566 - 1569
  • [35] Two models of early cardiac rehabilitation in male patients after myocardial infarction with preserved left ventricular function: comparison of standard out-patient versus hybrid training programmes
    Korzeniowska-Kubacka, Iwona
    Dobraszkiewicz-Wasilewska, Barbara
    Bilinska, Maria
    Rydzewska, Ewa
    Piotrowicz, Ryszard
    KARDIOLOGIA POLSKA, 2011, 69 (03) : 220 - 227
  • [36] Quantitative Assessment of Left Ventricular Size and Function in Patient With Arrthythmia: Comparison of One Heart Beat, Quantitative Full B-Mode Volume Real-Time Transthoracic Three-Dimensional Echocardiography (RT-3DE) With Cardiac Magnetic Resonance Imaging/Computed Tomography
    Choi, Jung-Hyun
    Michael, Snyder
    Liu, Shizhen
    Orsinelli, David
    Conwel, Barbara
    Ryan, Thomas
    Vannan, Mani A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A244 - A244
  • [37] Reproducibility of Left Ventricular Function Derived From Cardiac Magnetic Resonance and Gated 13NAmmonia Positron Emission Tomography Myocardial Perfusion Imaging: A Head-to-Head Comparison Using Hybrid Positron Emission Tomography/Magnetic Resonance
    Sager, Dominik F.
    Manz, Nico
    Manser, Sarah
    Laubscher, Lily
    Stark, Anselm W.
    Schutze, Jonathan
    Heiniger, Pascal S.
    Markendorf, Susanne
    Kaufmann, Philipp A.
    Grani, Christoph
    Buechel, Ronny R.
    ACADEMIC RADIOLOGY, 2024, 31 (04) : 1248 - 1255
  • [38] Assessment of left ventricular volumes with cardiac MRI: comparison between two semiautomated quantitative software packagesValutazione volumetrica del ventricolo sinistro mediante cardio-RM: confronto tra due software quantitativi semi-automatici
    G. Messalli
    A. Palumbo
    E. Maffei
    C. Martini
    S. Seitun
    A. Aldrovandi
    M. Imbriaco
    M. Salvatore
    A. Weustink
    N. Mollet
    F. Cademartiri
    La radiologia medica, 2009, 114 : 718 - 727
  • [39] Quantitative assessment of left ventricular size and function in cardiac transplant recipients: Side-by-side comparison of real time two-dimensional echocardiography, contrast-enhanced two-dimensional echocardiography, three-dimensional echocardiography, and contrast-enhanced three-dimensional echocardiography as compared to magnetic resonance imaging
    Rodriguez-Manero, Moises
    Azcarate-Aguero, Pedro
    Kreidieh, Bahij
    Teresa Alvez, Maria
    Martinez-Monzonis, Amparo
    Diaz-Dorronsoro, Agnes
    Cid-Menendez, Adrian
    Ramon Gonzalez-Juanatey, Jose
    Barba-Cosials, Joaquin
    Rabago, Gregorio
    Bastarrika, Gorka
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (02): : 306 - 311