Estimation of internal skin temperatures in response to cryogen spray cooling: Implications for laser therapy of port wine stains

被引:57
|
作者
Torres, JH [1 ]
Nelson, JS
Tanenbaum, BS
Milner, TE
Goodman, DM
Anvari, B
机构
[1] Rice Univ, Dept Bioengn, Houston, TX 77005 USA
[2] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
[3] Harvey Mudd Coll, Dept Engn, Claremont, CA 91711 USA
[4] Univ Texas, Dept Elect & Comp Engn, Austin, TX 78712 USA
[5] Univ Texas, Biomed Engn Program, Austin, TX 78712 USA
[6] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
cutaneous hypervascular lesions; dermatology; refrigerant; selective thermal injury; skin model;
D O I
10.1109/2944.796330
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In many port wine stain (PWS) patients, successful clearing is not achieved even after multiple laser treatments because of inadequate heat generation within the targeted blood vessels. Use of higher radiant exposures has been suggested to improve lesion clearing, but risk of epidermal injury due to nonspecific absorption by melanin increases. It has been demonstrated that cryogen spray cooling (CSC) can protect the epidermis from nonspecific thermal injury during laser treatment of PWS, Inasmuch as epidermal melanin concentration and blood vessel depth vary among patients, evaluation of internal skin temperatures in response to CSC is essential for further development and optimization of treatment parameters on an individual patient basis, We present internal temperature measurements in an epoxy resin phantom in response to CSC and use the results in conjunction with a mathematical model to predict the temperature distribution within human skin for various cooling parameters, Measurements on the epoxy resin phantom show that cryogen film temperature is well below the cryogen boiling point, but a poor thermal contact exists at the cryogen-phantom interface. Based on phantom measurements and model predictions, internal skin temperature reduction remains confined to the upper 400 mu m for spurt durations as long as 200 ms. At the end of a 100 ms spurt, our results show a 31 degrees C temperature reduction at the surface, 12 degrees C at a depth of 100 mu m, and 4 degrees C at a depth of 200 mu m in human skin. Analysis of estimated temperature distributions in response to CSC and temperature profiles obtained by pulsed photothermal radiometry indicates that a significant protective effect is achieved at the surface of laser irradiated PWS skin. Protection of the epidermal basal layer, however, poses a greater challenge when high radiant exposures are used.
引用
收藏
页码:1058 / 1066
页数:9
相关论文
共 50 条
  • [11] A THEORETICAL-STUDY OF THE THERMAL RESPONSE OF SKIN TO CRYOGEN SPRAY COOLING AND PULSED-LASER IRRADIATION - IMPLICATIONS FOR TREATMENT OF PORT-WINE STAIN BIRTHMARKS
    ANVARI, B
    TANENBAUM, BS
    MILNER, TE
    KIMEL, S
    SVAASAND, LO
    NELSON, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (09): : 1451 - 1465
  • [12] Cooling efficiency of cryogen spray during laser therapy of skin
    Svaasand, LO
    Randeberg, LL
    Aguilar, G
    Majaron, B
    Kimel, S
    Lavernia, EJ
    Nelson, JS
    LASERS IN SURGERY AND MEDICINE, 2003, 32 (02) : 137 - 142
  • [13] Optimization of cryogen spray cooling for port wine stain laser therapy using photoacoustic measurement of epidermal melanin
    Viator, JA
    Aguilar, G
    Jacques, SL
    Nelson, JS
    2003 ADVANCES IN BIOENGINEERING, 2003, : 13 - 14
  • [14] Internal temperature measurements in response to cryogen spray cooling of a skin phantom
    Torres, JH
    Anvari, B
    Tanenbaum, BS
    Milner, TE
    Yu, JC
    Nelson, JS
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS IX, PROCEEDINGS OF, 1999, 3590 : 11 - 19
  • [15] Laser therapy of port wine stains
    Trelles, MA
    INTERNATIONAL LASER CONGRESS: LASERS AT THE DAWN OF THE THIRD MILLENNIUM, 1996, : 107 - 118
  • [16] Definition of cryogen spray cooling efficiency: Improvement in port wine stain laser therapy through multiple-intermittent cryogen spurts and laser pulses
    Aguilar, G
    Lavernia, EJ
    Nelson, JS
    LASERS IN SURGERY AND MEDICINE, 2002, : 10 - 10
  • [17] Bioheat transfer analysis of cryogen spray cooling during laser treatment of port wine stains. (vol 26, pg 145, 2000)
    Pfefer, TJ
    Smithies, DJ
    Milner, TE
    van Gemert, MJC
    Nelson, JS
    Welch, AJ
    LASERS IN SURGERY AND MEDICINE, 2000, 26 (05) : 496 - 496
  • [18] A theoretical study of the thermal response of skin to cryogen spray cooling and pulsed laser irradiation: Implications for treatment of port wine stain birthmarks (vol 40, pg 1451, 1995)
    Anvari, B
    Tanenbaum, BS
    Milner, TE
    Kimel, S
    Svaasand, LO
    Nelson, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (07): : 1245 - 1245
  • [19] Evaporation characteristics of a single droplet in laser treatment of port wine stain in conjunction with cryogen spray cooling
    Zhou, Zhifu
    Xin, Hui
    Chen, Bin
    Wang, Guoxiang
    Zhongguo Jiguang/Chinese Journal of Lasers, 2008, 35 (06): : 952 - 956
  • [20] Treatment of port-wine stains by variable pulse width pulsed dye laser with cryogen spray: A preliminary study
    Lou, WW
    Geronemus, RG
    DERMATOLOGIC SURGERY, 2001, 27 (11) : 963 - 965