Fault ride-through capability improvement in a DFIG-based wind turbine using modified ADRC

被引:9
|
作者
Mosayyebi, Seyed Reza [1 ]
Shahalami, Seyed Hamid [1 ]
Mojallali, Hamed [1 ]
机构
[1] Univ Guilan, Fac Engn, Elect Engn Dept, Rasht, Iran
关键词
Doubly-fed induction generator (DFIG); Auto disturbance rejection control (ADRC); Fault ride-through (FRT); Wind turbine; Nonlinear fractional-order extended state observer (NFESO); FED INDUCTION GENERATOR; LOW-VOLTAGE RIDE; DISTURBANCE REJECTION CONTROL; POWER QUALITY CONDITIONER; CONTROL STRATEGY; PWM CONVERTERS; ENHANCEMENT; CONTROLLER; CONFIGURATION; POSITION;
D O I
10.1186/s41601-022-00272-9
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, an overview of several strategies for fault ride-through (FRT) capability improvement of a doubly-fed induction generator (DFIG)-based wind turbine is presented. Uncertainties and parameter variations have adverse effects on the performance of these strategies. It is desirable to use a control method that is robust to such disturbances. Auto disturbance rejection control (ADRC) is one of the most common methods for eliminating the effects of disturbances. To improve the performance of the conventional ADRC, a modified ADRC is introduced that is more robust to disturbances and offers better responses. The non-derivability of the fal function used in the conventional ADRC degrades its efficiency, so the modified ADRC uses alternative functions that are derivable at all points, i.e., the odd trigonometric and hyperbolic functions (arcsinh, arctan, and tanh). To improve the efficiency of the proposed ADRC, fuzzy logic and fractional-order functions are used simultaneously. In fuzzy fractional-order ADRC (FFOADRC), all disturbances are evaluated using a nonlinear fractional-order extended state observer (NFESO). The performance of the suggested structure is investigated in MATLAB/Simulink. The simulation results show that during disturbances such as network voltage sag/swell, using the modified ADRCs leads to smaller fluctuations in stator flux amplitude and DC-link voltage, lower variations in DFIG velocity, and lower total harmonic distortion (THD) of the stator current. This demonstrates the superiority over conventional ADRC and a proportional-integral (PI) controller. Also, by changing the crowbar resistance and using the modified ADRCs, the peak values of the waveforms (torque and currents) can be controlled at the moment of fault occurrence with no significant distortion.
引用
收藏
页数:37
相关论文
共 50 条
  • [41] Evaluation of Fault Ride Through Capability Enhancement of DFIG-Based Wind Turbine with Bi-2212 Superconducting Fault Current Limiter
    Romphochai, Sillawat
    Hongesombut, Komsan
    2015 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2015,
  • [42] Fault Current Unified Calculation Method for Whole Process Fault Ride-Through of DFIG-Based Wind Farms
    Liu, Xubin
    Zhang, Zijian
    Liu, Yonglu
    Liu, Zhangjie
    Su, Mei
    Li, Canbing
    Ge, Leijiao
    Zhang, Xin
    Wang, Peng
    IEEE TRANSACTIONS ON SMART GRID, 2024, 15 (01) : 485 - 503
  • [43] Enhancement of demagnetization control for low-voltage ride-through capability in DFIG-based wind farm
    M. Kenan Döşoğlu
    Uğur Güvenç
    Yusuf Sönmez
    Cemal Yılmaz
    Electrical Engineering, 2018, 100 : 491 - 498
  • [44] Enhancement of demagnetization control for low-voltage ride-through capability in DFIG-based wind farm
    Dosoglu, M. Kenan
    Guvenc, Ugur
    Sonmez, Yusuf
    Yilmaz, Cemal
    ELECTRICAL ENGINEERING, 2018, 100 (02) : 491 - 498
  • [45] Low voltage ride-through enhancement of DFIG-based wind turbine using DC link switchable resistive type fault current limiter
    Naderi, Seyed Behzad
    Negnevitsky, Michael
    Jalilian, Amin
    Hagh, Mehrdad Tarafdar
    Muttaqi, Kashem M.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2017, 86 : 104 - 119
  • [46] Enhancing Fault Ride-Through Capability of DFIG-Based WECS Using Dynamic Reconfiguration Hybrid Interlinking Transformer Technique
    Lai, Jinmu
    Liu, Yang
    Yin, Xin
    Jiang, Lin
    Yao, Wei
    Xiao, Fan
    Hu, Jiaxuan
    Ullah, Zia
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2025, 16 (02) : 1037 - 1055
  • [47] Dynamic Reactive Power in Compliance with Low Voltage Ride-Through Enhancement for DFIG-based Wind Turbine
    Gatavi, E.
    Hellany, A.
    Nagrial, M.
    Rizk, J.
    2017 ASIAN CONFERENCE ON ENERGY, POWER AND TRANSPORTATION ELECTRIFICATION (ACEPT), 2017,
  • [48] A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage Restorers
    Ibrahim, Ahmad Osman
    Thanh Hai Nguyen
    Lee, Dong-Choon
    Kim, Su-Chang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (03) : 871 - 882
  • [49] Improvement of Fault Ride Through Capability of Wind Farms using DFIG Considering SDBR
    Okedu, K. E.
    Muyeen, S. M.
    Takahashi, R.
    Tamura, J.
    PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011), 2011,
  • [50] Study on Application of New Approach of Fault Current Limiters in Fault Ride through Capability Improvement of DFIG Based Wind Turbine
    Naderi, Seyed Behzad
    Davari, Pooya
    Zhou, Dao
    Negnevitsky, Michael
    Blaabjerg, Frede
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,