Experimental and Numerical Analysis of Overhead Transmission Lines Vibration due to Atmospheric Icing

被引:0
|
作者
Liu, Bin [1 ]
Ji, Kunpeng [1 ]
Zhan, Xueping [1 ]
Fei, Xiangze [1 ]
Li, Peng [1 ]
Zhao, Bin [1 ]
Deng, Chun [2 ]
Liu, Liang [2 ]
Dong, Yongxing
Wang, Zhili [4 ]
Luo, Yongqin [3 ,4 ]
Bai, Yang [5 ]
机构
[1] China Elect Power Res Inst, Dept Transmiss & Distribut Engn, Beijing, Peoples R China
[2] Jibei Elect Power Res Inst, Beijing, Peoples R China
[3] North China Elect Power Univ, Sch Energy Power & Mech Engn, Beijing, Peoples R China
[4] State Grid Shanxi Elect Power Co, Taiyuan, Shanxi, Peoples R China
[5] State Grid Shanxi Elect Power Res Inst, Taiyuan, Shanxi, Peoples R China
基金
北京市自然科学基金;
关键词
transmission line; dynamic characteristics; finite element method; ice shedding; ICE; SIMULATION; CONDUCTORS;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Atmospheric icing is one of the main threats to overhead transmission lines in cold regions. The ice related loads may cause mechanical incidents, such as wire breakage, cable rupture, clamp slipping, cross-arm deformation and even tower collapse. Ice shedding may lead to dramatic vibration of lines and cause flashover or short circuit among ground wires, conductors and the earth. Therefore, to obtain the static and dynamic load characteristics of the overhead electric transmission lines is essential for transmission line design and operation. Also, it provides important information for health evaluation of transmission line components, and prediction of their remaining service life. In present study, a three-span full scale physical model of transmission line was established, with the span length of 50m-150m-50m. Ice shedding was simulated by sudden release of lumped mass. The mid-span jump heights were measured during different ice shedding scenarios, to quantizing the dynamic characteristics of lines. Then, finite element method (FEM) was employed for numerical simulation of ice shedding phenomenon. The comparison of numerical and experimental results confirms the feasibility and efficiency of the numerical simulation method in this paper. This study provides essential experimental data about ice shedding of full scale transmission lines, and is of great help for transmission line design and icing disaster alleviation.
引用
收藏
页码:1117 / 1120
页数:4
相关论文
共 50 条
  • [41] Analysis of the Climatic Factors Influence on the Overhead Transmission Lines Reliability
    Kondrateva, Olga
    Myasnikova, Ekaterina
    Loktionov, Oleg
    ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, 2020, 24 (03) : 201 - 214
  • [42] Analysis of Corona on Hybrid DC and AC Overhead Transmission Lines
    El-Deen, Seham Kamal
    Abdel-Salam, Mazen
    El-Mohandes, Mohamed Th.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2023, 51 (10) : 2926 - 2941
  • [43] Lightning performance analysis of overhead transmission lines using the EMTP
    Martinez, JA
    Castro-Aranda, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 2200 - 2210
  • [44] Tower modeling for lightning analysis of. overhead transmission lines
    Martinez, JA
    Castro-Aranda, F
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 1212 - 1217
  • [45] Analysis of Lightning-Induced Voltages in Overhead Transmission Lines
    Boumaiza, Mostefa
    Labed, Djamel
    TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY (TMREES14 - EUMISD), 2014, 50 : 41 - 49
  • [46] Transient Analysis of Overhead Transmission Lines Based on Fitting Methods
    Colqui, Jaimis S. L.
    Araujo, Anderson R. J.
    Pascoalato, Taina F. G.
    Kurokawa, Sergio
    2021 14TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2021, : 180 - 187
  • [47] Analysis of the effect of climate change on the reliability of overhead transmission lines
    Rezaei, Seyedeh Nasim
    Chouinard, Luc
    Langlois, Sebastien
    Legeron, Frederic
    SUSTAINABLE CITIES AND SOCIETY, 2016, 27 : 137 - 144
  • [48] Design and Experiment of FBG-Based Icing Monitoring on Overhead Transmission Lines with an Improvement Trial for Windy Weather
    Zhang, Min
    Xing, Yimeng
    Zhang, Zhiguo
    Chen, Qiguan
    SENSORS, 2014, 14 (12): : 23954 - 23969
  • [49] PARAMETRIC OPTIMIZATION OF WIND-EXCITED VIBRATION DAMPERS FOR OVERHEAD TRANSMISSION-LINES
    CORRIGA, G
    SANNA, S
    USAI, G
    APPLIED MATHEMATICAL MODELLING, 1994, 18 (10) : 577 - 581
  • [50] Prevention Measures for Flashover Performance of Insulators under Icing Conditions on 330kV Overhead Transmission Lines
    Pu, Lu
    Qian, Sen
    Xu, Yang
    Xie, Xiuyu
    Cao, Xiaolong
    2011 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 2011, : 387 - 389