Off-line and On-line Detection of PD in Inverter-Fed Random-Wound Motor Considering IEC Technical Specifications

被引:0
|
作者
Hiroshima, Satoshi [1 ]
Hirose, Tatsuya [1 ]
Sakai, Masahiro [1 ]
Hatano, Hiroshi [1 ]
Yoshimitsu, Tetsuo [2 ]
Sakurai, Takayuki [2 ]
Ikegami, Tomomi [2 ]
机构
[1] Toshiba Co Ltd, Yokohama, Kanagawa 2300045, Japan
[2] Toshiba Mitsubishi Elect Ind Syst Corp, Yokohama, Kanagawa 2300045, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the inverter-fed motor, the surge voltages with fast rise time and high voltage peak may cause partial discharge (PD) which potentially damages the electrical insulation system. Off-line tests with an impulse generator are executed under the IEC technical specifications of TS60034-18-41 (2006) and TS61934 (2011) for insulation systems of low-voltage motors fed from inverters, which are required of PD free in their expected service lives. On-line tests are executed during operation of an actual motor fed from a PWM inverter, since the PD properties may differ from the off-line's ones. This paper mainly discusses the detection sensitivity of PD for off-line and on-line tests using the PD detector at motor terminal. Firstly, effects on PD signal at the motor terminal in the stator windings under surge voltage are examined, when PD signal propagates through some coils after generating PD in the twisted pair that is connected to the motor winding purposely. In our test conditions, it is confirmed that PD signal propagating through the motor winding to the motor terminal can be detected correctly. Secondly, effects of noises on detection sensitivity are examined. It is concluded that the residual surge noise signals from an inverter or an impulse generator can be excluded using the high-pass filter of the appropriate selected frequency, then PD signals can be easily recognized, even for on-line tests. Finally, the transient noises hardly have effect on the PD detection of off-line tests under an IEC-TS61934, since the time range required for the PD distinction of off-line tests is extremely shorter than of power frequency tests. These testing results and considerations may be useful for the standardizations of the IEC TS60034-18-41 and TS 61934 in the near future.
引用
收藏
页码:72 / 75
页数:4
相关论文
共 8 条
  • [1] Partial Discharge in Electric Motor Fed by a PWM Inverter: Off-line and On-line Detection
    Billard, T.
    Lebey, T.
    Fresnet, F.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 1235 - 1242
  • [2] Techniques for off-line measurement and analysis of PD pulses in inverter-fed induction motors
    Cavallini, A
    Montanari, GC
    Contin, A
    Qinxue, Y
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 1071 - 1075
  • [3] On-line and Off-line Fault Detection Techniques for Inverter Based Islanded Microgrid
    Thattai, Kuthsav
    Sahoo, Animesh
    Ravishankar, Jayashri
    [J]. PROCEEDINGS 2018 IEEE 12TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING (CPE-POWERENG 2018), 2018,
  • [4] Study on the location method of insulation weak point for low-voltage random-wound inverter-fed motor
    Guo, Houlin
    Wang, Peng
    Lin, Hai
    Luo, Yinglu
    Ma, Shijin
    [J]. Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (11): : 140 - 149
  • [5] Off-Line and On-Line PD Measurements on Induction Motors Fed by Power Electronic Impulses
    Tozzi, M.
    Montanari, G. C.
    Fabiani, D.
    Cavallini, A.
    Gao, G.
    [J]. 2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 420 - +
  • [6] RECENT DEVELOPMENTS IN IEEE AND IEC STANDARDS FOR OFF-LINE AND ON-LINE PARTIAL DISCHARGE TESTING OF MOTOR AND GENERATOR STATOR WINDINGS
    Stone, G. C.
    Stranges, Meredith K. W.
    Dunn, Donald G.
    [J]. 2014 IEEE PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE (PCIC), 2014,
  • [7] On-Line Stator Turn Fault Detection for Inverter-Fed Electric Machines Using Neutral Point Voltage Differences
    Yang, Shih-Chin
    [J]. 2015 IEEE 2ND INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE (IFEEC), 2015,
  • [8] Off-line PD Testing of Converter-fed Wire-wound Motors: When IEC TS 60034-18-41 May Fail?
    Cavallini, A.
    Lindell, E.
    Montanari, G. C.
    Tozzi, M.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (05) : 1385 - 1395