Off-Line and On-Line PD Measurements on Induction Motors Fed by Power Electronic Impulses

被引:17
|
作者
Tozzi, M. [1 ]
Montanari, G. C. [1 ]
Fabiani, D. [1 ]
Cavallini, A. [1 ]
Gao, G. [2 ]
机构
[1] Univ Bologna, DIE, LIMAT, Viale Risorgimento 2, I-40136 Bologna, Italy
[2] TECO Westinghouse Motor Co, R&D Ctr, Round Rock 78681, TX USA
关键词
D O I
10.1109/EIC.2009.5166383
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial Discharge (PD) off-line and on-tine measurements are required to prevent early failures on low voltage induction motors fed by inverter drives. Conventional methods use commercial Digital Scopes to visualize simultaneously the waveform of the applied impulsive voltage and the acquired PD pulses, as well as appropriate solutions to attenuate power electronic voltage impulses. A new approach is proposed in this paper, relying upon a Phase-Resolved PD (PRPD) pattern, which constitutes a simple and efficient tool for PD activity detection in adjustable speed drives. Off-line PD measurements were done on low voltage induction motors fed by a voltage impulse generator and detecting PD Inception Voltage (PDIV) on each phase. Then, PD on line measurements were carried out using a commercial PWM inverter and showing interesting correlation between off-line and on-fine tests. All the measurements were performed using antenna sensors, achieving excellent sensitivity.
引用
收藏
页码:420 / +
页数:2
相关论文
共 50 条
  • [1] Monitoring Off-line and On-line PD Under Impulsive Voltage on Induction Motors - Part 2: Testing
    Tozzi, M.
    Cavallini, A.
    Montanari, G. C.
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2011, 27 (01) : 14 - 21
  • [2] Monitoring Off-Line and On-Line PD Under Impulsive Voltage on Induction Motors - Part 3: Criticality
    Tozzi, M.
    Cavallini, A.
    Montanari, G. C.
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2011, 27 (04) : 26 - 33
  • [3] Monitoring Off-Line and On-Line PD Under Impulsive Voltage on Induction Motors - Part 1: Standard Procedure
    Tozzi, M.
    Cavallini, A.
    Montanari, G. C.
    [J]. IEEE ELECTRICAL INSULATION MAGAZINE, 2010, 26 (04) : 16 - 26
  • [4] Techniques for off-line measurement and analysis of PD pulses in inverter-fed induction motors
    Cavallini, A
    Montanari, GC
    Contin, A
    Qinxue, Y
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 1071 - 1075
  • [5] Aspect of on-line and off-line PD diagnosis of distribution power cables
    Wester, F
    Gulski, E
    Smit, J
    Groot, E
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 553 - 556
  • [6] Comparison of off-line and on-line partial discharge for large motors
    Kim, HD
    Ju, YH
    [J]. CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, 2002, : 27 - 30
  • [7] On-line and off-line state of the art preventive maintenance of electrical motors
    Wiedenbrug, EJ
    [J]. ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, PROCEEDINGS, 2001, : 627 - 634
  • [8] Is the Notion of Divisible On-Line/Off-Line Signatures Stronger than On-Line/Off-Line Signatures?
    Au, Man Ho
    Susilo, Willy
    Mu, Yi
    [J]. PROVABLE SECURITY, PROCEEDINGS, 2009, 5848 : 129 - 139
  • [9] A comparison of on-line and off-line bioaerosol measurements at a biowaste site
    Feeney, Patrick
    Fernandez Rodriguez, Santiago
    Molina, Rafael
    McGillicuddy, Eoin
    Hellebust, Stig
    Quirke, Michael
    Daly, Shane
    O'Connor, David
    Sodeau, John
    [J]. WASTE MANAGEMENT, 2018, 76 : 323 - 338
  • [10] Comparison of on-line and off-line PD analysis on stator insulation of turbogenerators
    Zondervan, JP
    Gulski, E
    Smit, JJ
    Krieg-Wezelenburg, MG
    [J]. CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 270 - 273