Experimental study and calculation of fire resistance of concrete-filled hollow steel columns

被引:161
|
作者
Han, LH
Zhao, XL
Yang, YF
Feng, JB
机构
[1] Fuzhou Univ, Coll Civil Engn & Architecture, Fuzhou 350002, Fujian, Peoples R China
[2] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[3] Monash Univ, Dept Civil Engn, Clayton, Vic 3168, Australia
关键词
steel columns; fire resistance; concrete; beam columns; hollow sections;
D O I
10.1061/(ASCE)0733-9445(2003)129:3(346)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Hollow structural steel (HSS) columns filled with concrete offer a number of benefits and are often used in tall buildings and other industrial structures. A mathematical model was developed and used to investigate the influence of important parameters that determine the fire resistance of concrete-filled hollow steel columns. The behavior of concrete-filled HSS columns with or without fire protection subjected to axial or eccentric loads was experimentally investigated and the results presented in this paper. The parametric and experimental studies provide information for the development of formulas for the calculation of the fire resistance and fire protection thickness of the composite columns. The main objectives of this work were threefold: First, to report a series of fire tests on composite columns; second, to analyze the influence of several parameters, such as the sectional dimension, load eccentricity ratio, and fire protection thickness on the fire resistance of the composite columns. It was found, in general, that the sectional dimension and the fire protection thickness have significant influence on the fire resistance of concrete-filled HSS columns; however, the load eccentricity ratio has moderate influence on the fire resistance. The final objective was to develop formulas for the calculation of the fire resistance and the fire protection thickness of the concrete-filled HSS columns.
引用
收藏
页码:346 / 356
页数:11
相关论文
共 50 条
  • [31] Fire resistance of concrete-filled steel tube columns with preload. Part I: Experimental investigation
    Yu, Min
    Wang, Tan
    Huang, Weijun
    Yuan, Huanxin
    Ye, Jianqiao
    COMPOSITE STRUCTURES, 2019, 223
  • [32] EXPERIMENTAL-STUDY OF CONCRETE-FILLED RECTANGULAR HOLLOW SECTION COLUMNS
    SHAKIRKHALIL, H
    STRUCTURAL ENGINEERING REVIEW, 1994, 6 (02): : 85 - 96
  • [33] Experimental Study on Fire Resistance Performance of Concrete-Filled Steel Plate Composite Walls
    Zhou, Ting
    Liu, Xueshan
    Liu, Hongbo
    Li, Yixuan
    Zhang, Pengfei
    Chen, Huazhou
    Chen, Zhihua
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2023, 23 (02) : 389 - 403
  • [34] Experimental Study on Fire Resistance Performance of Concrete-Filled Steel Plate Composite Walls
    Ting Zhou
    Xueshan Liu
    Hongbo Liu
    Yixuan Li
    Pengfei Zhang
    Huazhou Chen
    Zhihua Chen
    International Journal of Steel Structures, 2023, 23 : 389 - 403
  • [35] Concrete-filled steel columns
    Kodur, V.K.R.
    Canadian Consulting Engineer, 1998, 39 (Special Issu):
  • [36] A unified method for calculating fire resistance of solid and hollow concrete-filled steel tube columns based on average temperature
    Yu, Min
    Zha, Xiaoxiong
    Ye, Jianqiao
    Wang, Baolin
    ENGINEERING STRUCTURES, 2014, 71 : 12 - 22
  • [37] High strength concrete-filled tubular steel columns in fire
    Bahr, O.
    TUBULAR STRUCTURES XII, 2009, : 461 - 467
  • [38] Fire Resistance Tests on Concrete-Filled Steel Tubular Columns with Geopolymeric Recycled Aggregate
    Tian-Yi Song
    Xing-Yu Qu
    Zhu Pan
    Kai Xiang
    Hongyuan Zhou
    Fire Technology, 2022, 58 : 2727 - 2754
  • [39] Fire Resistance Tests on Concrete-Filled Steel Tubular Columns with Geopolymeric Recycled Aggregate
    Song, Tian-Yi
    Qu, Xing-Yu
    Pan, Zhu
    Xiang, Kai
    Zhou, Hongyuan
    FIRE TECHNOLOGY, 2022, 58 (05) : 2727 - 2754
  • [40] Experimental data analysis of concrete-filled steel columns
    Goode, C. Douglas
    Kuranovas, Artiomas
    Kvedaras, Audronis Kazimieras
    9TH INTERNATIONAL CONFERENCE: MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, VOLS 1-3, 2008, : 546 - +