Monte Carlo Approach for Uncertainty Analysis of Acoustic Doppler Current Profiler Discharge Measurement by Moving Boat

被引:16
|
作者
Moore, Stephanie A. [1 ]
Jamieson, Elizabeth C. [1 ]
Rainville, Francois [1 ]
Rennie, Colin D. [2 ]
Mueller, David S. [3 ]
机构
[1] Water Survey Canada, Environm & Climate Change Canada, 373 Sussex Dr, Ottawa, ON K1A 0H3, Canada
[2] Univ Ottawa, Dept Civil Engn, 161 Louis Pasteur Pvt, Ottawa, ON K1N 6N5, Canada
[3] US Geol Survey, Off Surface Water, Louisville, KY 40299 USA
关键词
Moving-boat acoustic Doppler current profiler (ADCP); Uncertainty; Monte Carlo; Probabilistic; Stream gauging procedures; ADCP VELOCITY; VARIANCE;
D O I
10.1061/(ASCE)HY.1943-7900.0001249
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a method using Monte Carlo simulations for assessing uncertainty of moving-boat acoustic Doppler current profiler (ADCP) discharge measurements using a software tool known as QUant, which was developed for this purpose. Analysis was performed on 10 data sets from four Water Survey of Canada gauging stations in order to evaluate the relative contribution of a range of error sources to the total estimated uncertainty. The factors that differed among data sets included the fraction of unmeasured discharge relative to the total discharge, flow nonuniformity, and operator decisions about instrument programming and measurement cross section. As anticipated, it was found that the estimated uncertainty is dominated by uncertainty of the discharge in the unmeasured areas, highlighting the importance of appropriate selection of the site, the instrument, and the user inputs required to estimate the unmeasured discharge. The main contributor to uncertainty was invalid data, but spatial inhomogeneity in water velocity and bottom-track velocity also contributed, as did variation in the edge velocity, uncertainty in the edge distances, edge coefficients, and the top and bottom extrapolation methods. To a lesser extent, spatial inhomogeneity in the bottom depth also contributed to the total uncertainty, as did uncertainty in the ADCP draft at shallow sites. The estimated uncertainties from QUant can be used to assess the adequacy of standard operating procedures. They also provide quantitative feedback to the ADCP operators about the quality of their measurements, indicating which parameters are contributing most to uncertainty, and perhaps even highlighting ways in which uncertainty can be reduced. Additionally, QUant can be used to account for self-dependent error sources such as heading errors, which are a function of heading. The results demonstrate the importance of a Monte Carlo method tool such as QUant for quantifying random and bias errors when evaluating the uncertainty of moving-boat ADCP measurements.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Validation of an Uncertainty Propagation Method for Moving-Boat Acoustic Doppler Current Profiler Discharge Measurements
    Despax, Aurelien
    Le Coz, Jerome
    Mueller, David S. S.
    Hauet, Alexandre
    Calmel, Blaise
    Pierrefeu, Gilles
    Naudet, Gregoire
    Blanquart, Bertrand
    Pobanz, Karine
    WATER RESOURCES RESEARCH, 2023, 59 (01)
  • [2] Estimating uncertainty of streamflow measurements with moving-boat acoustic Doppler current profilers
    Huang, Hening
    HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 2018, 63 (03): : 353 - 368
  • [3] MOVING BOAT DISCHARGE MEASUREMENTS USING ACOUSTIC DOPPLER TECHNIQUES
    SCHNEIDER, VR
    BILLINGS, RH
    HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 1982, 27 (02): : 179 - 180
  • [4] Discharge measurement of rapid streamflow using an Acoustic Doppler Profiler
    J.-Y. Lu
    C.-Y. Wang
    C.-C. Su
    Experimental Techniques, 1998, 22 : 25 - 28
  • [5] Discharge measurement of rapid streamflow using an acoustic Doppler profiler
    Lu, JY
    Wang, CY
    Su, CC
    EXPERIMENTAL TECHNIQUES, 1998, 22 (06) : 25 - 28
  • [6] Visualization analysis and Acoustic Doppler Current Profiler measurements by using the Acoustic Doppler Current Profiler river flow analyzer
    Wang, Hau-Wei
    Li, Shih-Chiang
    Hong, Jian-Hao
    Chen, Cheng-Hsin
    Wang, Yu-Chi
    RIVER FLOW 2016, 2016, : 1504 - 1509
  • [7] Current Profile Measurement Using Moored Acoustic Doppler Current Profiler
    Skelin, Drazan
    Bublic, Ivan
    Vukadin, Predrag
    PROCEEDINGS ELMAR-2008, VOLS 1 AND 2, 2008, : 411 - 414
  • [8] River Discharge Measurement with Acoustic Doppler Profiler during Typhoon Flood
    Lin, Ying-Chih
    Peng, Chih-Hsiung
    Chan, Hsun-Chuan
    Leu, Jan-Mou
    PROCEEDINGS OF THE 35TH IAHR WORLD CONGRESS, VOLS I AND II, 2013, : 5766 - 5772
  • [9] Measurement of bed load velocity using an acoustic Doppler current profiler
    Rennie, CD
    Millar, RG
    Church, MA
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2002, 128 (05): : 473 - 483
  • [10] Moving vessel acoustic Doppler current profiler measurement of tidal stream function using radial basis functions
    Vennell, Ross
    Beatson, Rick
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 2006, 111 (C9)