Fabrication and evaluation of a graphene oxide-based cantilever-type flow-meter for subsonic gas flow rate measurement

被引:7
|
作者
Hamdollahi, Hassan [1 ]
Rahbar-Shahrouzi, Javad [1 ]
机构
[1] Sahand Univ Technol, Fac Chem Engn, Tabriz, Iran
关键词
flow meter; cantilever; graphene oxide; piezoresistive material; latex; SENSOR; ARRAYS; CELLS; PAPER;
D O I
10.1088/1361-6501/aaaa47
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, a cantilever-type flow meter was fabricated to measure the rate of air flow in turbulent subsonic regimes such as purged gases. In the fabrication process, a piezoresistive material was coated on an interdigitated electric board as a substrate. The piezoresistive layer was a blend of latex as the polymeric matrix and graphene oxide as the sensing nanomaterial agent, which was reduced by solvothermal reduction method. The piezoresistive blend was dip-coated on a substrate with dotted pattern and was then reduced at 240 degrees C for 1 h in every coating step. When an air flow passed over the surface of the cantilever beam, the beam was bent in the downward direction, resulting in small variations in the resistance of the piezoresistive layer and a change in the bending angle of the cantilever which were measured simultaneously. The air flow rate was acquired via calibrating electrical resistance changes by Arduino and Wheatstone bridge circuit. The blending angle of the substrate caused by the interaction between the airflow and the cantilever and recorded by the camera and image processing was ultimately compared with the simulation results. The flow meter accuracy as a percentage of full scale (% FS) was calculated to be +/- 5.8%, and mean deviation was equal to 2.1 (% FS) with the appropriate response time of 0.70 s at the air flow range of 100-240 m s(-1). Highlights A cantilever-type flow meter was fabricated to measure the high-speed air flow rate. The sensitive piezoresistive material was composed of GO and latex. The dip-coating method was used to deposit the piezoresistive layer on the fiberglass substrate. The impact of effective parameters on the performance of the flow meter was investigated. A simulation study was performed and the results were compared with the experimental data.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A comparative study of flow rate characteristics of an averaging Pitot tube type flow meter according to H parameters based on two kinds of differential pressure measured at the flow meter with varying air temperature
    Oh, Dae-San
    Lee, Choong-Hoon
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2011, 25 (08) : 1961 - 1967
  • [32] Research and realization of ultrasonic gas flow rate measurement based on ultrasonic exponential model
    Zheng, Dandan
    Hou, Huirang
    Zhang, Tao
    ULTRASONICS, 2016, 67 : 112 - 119
  • [33] GAS INDEPENDENT THERMAL FLOW METER BASED ON REAL-TIME VELOCITY-INDEPENDENT κ AND ρcp MEASUREMENT
    Kenari, Shirin Azadi
    Wiegerink, Remco J.
    Sanders, Remco G. P.
    Lotters, Joost C.
    2024 IEEE 37TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS, 2024, : 801 - 804
  • [34] Permselectivity and Ionic Conductivity Study of Na+ and Br- Ions in Graphene Oxide-Based Membranes for Redox Flow Batteries
    Flack, Raphael
    Aixala-Perello, Anna
    Pedico, Alessandro
    Saadi, Kobby
    Lamberti, Andrea
    Zitoun, David
    MEMBRANES, 2023, 13 (08)
  • [35] Soft measurement model for wet gas flow rate based on ultrasonic and differential pressure sensing
    Zheng, Dandan
    Shao, Simin
    Liu, Anna
    Wang, Maosen
    Li, Tao
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (05)
  • [36] Study on wet gas online flow rate measurement based on dual slotted orifice plate
    Li Yuxing
    Wang Jun
    Geng Yanfeng
    FLOW MEASUREMENT AND INSTRUMENTATION, 2009, 20 (4-5) : 168 - 173
  • [37] THRESHOLD GAS-FLOW RATE OF HALIDE MATERIALS FOR THE FORMATION OF OXIDE PARTICLES IN THE VAD PROCESS FOR OPTICAL FIBER FABRICATION
    KAWACHI, M
    SUDO, S
    EDAHIRO, T
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1981, 20 (04) : 709 - 712
  • [38] Evaluation of the gas absorption performance of a flow-type hydrate-based gas uptake system
    Ezure, Ryosuke
    Matsumoto, Yuto
    Takano, Shun
    Shimizu, Mana
    Komatsu, Hiroyuki
    Yamagiwa, Kazuaki
    Tajima, Hideo
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2020, 156 : 131 - 137
  • [39] Erratum to “Measurement of gas-liquid two-phase slug flow with a Venturi meter based on blind source separation”
    Weiwei Wang
    Xiao Liang
    Mingzhu Zhang
    Chinese Journal of Chemical Engineering, 2015, 23 (11) : 1923 - 1923
  • [40] A novel technique for solid mass loading measurement in dilute gas-solid two-phase flow by vortex flow meter based on vortex shedding principles
    Farahzadi, Hamzeh
    Shirvani, Mansour
    Hashemabadi, Seyed Hassan
    ASIA-PACIFIC JOURNAL OF CHEMICAL ENGINEERING, 2019, 14 (05)