Fabrication and evaluation of a graphene oxide-based cantilever-type flow-meter for subsonic gas flow rate measurement

被引:7
|
作者
Hamdollahi, Hassan [1 ]
Rahbar-Shahrouzi, Javad [1 ]
机构
[1] Sahand Univ Technol, Fac Chem Engn, Tabriz, Iran
关键词
flow meter; cantilever; graphene oxide; piezoresistive material; latex; SENSOR; ARRAYS; CELLS; PAPER;
D O I
10.1088/1361-6501/aaaa47
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, a cantilever-type flow meter was fabricated to measure the rate of air flow in turbulent subsonic regimes such as purged gases. In the fabrication process, a piezoresistive material was coated on an interdigitated electric board as a substrate. The piezoresistive layer was a blend of latex as the polymeric matrix and graphene oxide as the sensing nanomaterial agent, which was reduced by solvothermal reduction method. The piezoresistive blend was dip-coated on a substrate with dotted pattern and was then reduced at 240 degrees C for 1 h in every coating step. When an air flow passed over the surface of the cantilever beam, the beam was bent in the downward direction, resulting in small variations in the resistance of the piezoresistive layer and a change in the bending angle of the cantilever which were measured simultaneously. The air flow rate was acquired via calibrating electrical resistance changes by Arduino and Wheatstone bridge circuit. The blending angle of the substrate caused by the interaction between the airflow and the cantilever and recorded by the camera and image processing was ultimately compared with the simulation results. The flow meter accuracy as a percentage of full scale (% FS) was calculated to be +/- 5.8%, and mean deviation was equal to 2.1 (% FS) with the appropriate response time of 0.70 s at the air flow range of 100-240 m s(-1). Highlights A cantilever-type flow meter was fabricated to measure the high-speed air flow rate. The sensitive piezoresistive material was composed of GO and latex. The dip-coating method was used to deposit the piezoresistive layer on the fiberglass substrate. The impact of effective parameters on the performance of the flow meter was investigated. A simulation study was performed and the results were compared with the experimental data.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Multipath ultrasonic gas flow-meter based on multiple reference waves
    Zhou, Hongliang
    Ji, Tao
    Wang, Ruichen
    Ge, Xiaocheng
    Tang, Xiaoyu
    Tang, Shizhen
    ULTRASONICS, 2018, 82 : 145 - 152
  • [2] Analysis of Sealing Properties of Coupled Gas Film Flow Field and Cantilever-type Foil Deformation
    Ma, Gang
    Du, Yunlong
    APPLIED MECHANICS, MATERIALS AND MANUFACTURING IV, 2014, 670-671 : 856 - 859
  • [3] Fabrication and Evaluation of a Graphene Oxide-Based Capacitive Humidity Sensor †
    Feng, Jinfeng
    Kang, Xiaoxu
    Zuo, Qingyun
    Yuan, Chao
    Wang, Weijun
    Zhao, Yuhang
    Zhu, Limin
    Lu, Hanwei
    Chen, Juying
    SENSORS, 2016, 16 (03):
  • [4] Echo signal envelope fitting based signal processing methods for ultrasonic gas flow-meter
    Mu, Li-Bin
    Xu, Ke-Jun
    Liu, Bo
    Tian, Lei
    Liang, Li-Ping
    ISA TRANSACTIONS, 2019, 89 : 233 - 244
  • [5] The Development and Design of the Gas-Liquid Two-Phase Flow-meter System Based on DSP
    Zhu, Ji-Wei
    2008 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTER THEORY AND ENGINEERING, 2008, : 978 - 981
  • [6] Effect of gas temperature on flow rate characteristics of an averaging pitot tube type flow meter
    Yeo, Seung Hwa
    Lee, Su Ryong
    Lee, Choong Hoon
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2015, 29 (01) : 241 - 249
  • [7] Effect of gas temperature on flow rate characteristics of an averaging pitot tube type flow meter
    Seung Hwa Yeo
    Su Ryong Lee
    Choong Hoon Lee
    Journal of Mechanical Science and Technology, 2015, 29 : 241 - 249
  • [8] Design and fabrication of micro-windmill for fluidic media based on SU-8 for using flow-meter
    Alirezaei, I. Sabri
    Ghaderi, M.
    Khalafi, M.
    Latifi, H.
    MICRO-OPTICS 2012, 2012, 8428
  • [9] MEASUREMENT OF THE FLOW RATE AND VOLUME VOID FRACTION OF GAS-LIQUID BUBBLE FLOW USING A VORTEX FLOW METER
    Sun, Zhiqiang
    Zhang, Hongjian
    CHEMICAL ENGINEERING COMMUNICATIONS, 2010, 197 (02) : 145 - 157
  • [10] Flow Rate Measurement of Oil/Gas/Water Three-Phase Flow with V-Cone Flow Meter
    Zhang, F. S.
    Dong, F.
    6TH INTERNATIONAL SYMPOSIUM ON MULTIPHASE FLOW, HEAT MASS TRANSFER AND ENERGY CONVERSION, 2010, 1207 : 178 - 182