Effect of Humidity on Negative Corona Discharge of Electrostatic Precipitators

被引:59
|
作者
Wang, Xiaohua [1 ]
You, Changfu [1 ]
机构
[1] Tsinghua Univ, Dept Thermal Engn, Minist Educ, Key Lab Thermal Sci & Power Engn, Beijing 100084, Peoples R China
关键词
Peek formula; corona inception electric field; electrostatic precipitators; humidity; STREAMER PROPAGATION; NUMERICAL-SIMULATION; AIR; FIELDS;
D O I
10.1109/TDEI.2013.6633702
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effect of humidity on the negative corona discharge of electrostatic precipitators was experimentally and numerically studied. The current-voltage characteristics of a wire-plate electrostatic precipitator was measured over a range of temperatures and relative humidities. The inception voltage and electric field were determined based on the streamer theory. A numerical method was used to study the influence of humidity on the distributions of electric field and charge density in an electrostatic precipitator. The results showed that the inception voltage and electric field decreased with the increase of humidity. The corona current was significantly affected by the humidity. A modified Peek formula was proposed with a correction to the humidity. The corona currents calculated with the modified Peek formula were in acceptable agreement with the experimental results. The distributions of electric field and charge density were affected by the humidity and applied voltage.
引用
收藏
页码:1720 / 1726
页数:7
相关论文
共 50 条
  • [11] Characterization of brush type discharge electrodes and impact of enhanced corona discharge on operation of electrostatic precipitators
    Tahir, M. Suleman
    Saleem, M.
    Siebenhofer, M.
    JOURNAL OF ELECTROSTATICS, 2012, 70 (01) : 144 - 148
  • [12] A domain decomposition method for three species modeling of multi-electrode negative corona discharge - With applications to electrostatic precipitators
    Wettervik, Benjamin
    Johnson, Tomas
    Jakobsson, Stefan
    Mark, Andreas
    Edelvik, Fredrik
    JOURNAL OF ELECTROSTATICS, 2015, 77 : 139 - 146
  • [13] The effect of relative humidity on corona discharge
    Jiang, Song
    Huang, Jingchen
    Hoshino, Yasushi
    NIP 23: 23RD INTERNATIONAL CONFERENCE ON DIGITAL PRINTING TECHNOLOGIES, TECHNICAL PROGRAM AND PROCEEDINGS/DIGITAL FABRICATION 2007, 2007, : 56 - 60
  • [14] Influence of humidity on the characteristics of negative corona discharge in air
    Xu, Pengfei
    Zhang, Bo
    He, Jinliang
    Chen, Shuiming
    PHYSICS OF PLASMAS, 2015, 22 (09)
  • [15] OZONE GENERATION IN POSITIVE CORONA ELECTROSTATIC PRECIPITATORS
    CASTLE, GSP
    INCULET, II
    BURGESS, KI
    IEEE TRANSACTIONS ON INDUSTRY AND GENERAL APPLICATIONS, 1969, IGA5 (04): : 489 - &
  • [16] NEGATIVE CORONA IN WIRE PLATE ELECTROSTATIC PRECIPITATORS .1. CHARACTERISTICS OF INDIVIDUAL TUFT-CORONA DISCHARGES
    LAWLESS, PA
    MCLEAN, KJ
    SPARKS, LE
    RAMSEY, GH
    JOURNAL OF ELECTROSTATICS, 1986, 18 (02) : 199 - 217
  • [17] Modelling of the effect of electrode geometries on the corona discharge current-voltage characteristic for wire-plate electrostatic precipitators
    Brocilo, D
    Chang, JS
    Findlay, RD
    Kawada, Y
    Ito, T
    2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 681 - 684
  • [18] Effect of humidity and air pressure on the discharge modes transition characteristics of negative DC corona
    Chen, She
    Li, Kelin
    Wang, Feng
    Sun, Qiuqin
    Zhong, Lipeng
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (08) : 1212 - 1218
  • [19] NEGATIVE CORONA IN WIRE-PLATE ELECTROSTATIC PRECIPITATORS. PART II: CALCULATION OF ELECTRICAL CHARACTERISTICS OF CONTAMINATED DISCHARGE ELECTRODES.
    McLean, Kenneth J.
    Lawless, Phil A.
    Sparks, Leslie E.
    Ramsey, Geddes H.
    1600, (18):
  • [20] Effect of humidity on negative corona Trichel pulses
    Deng, Fucheng
    Ye, Lingyun
    Song, Kaichen
    Huang, Tiantian
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (08)