A non-contact capacitance type level transducer for liquid characterization

被引:5
|
作者
Khan, Sheroz Khalifa [1 ]
Ali, Kyaw Kyaw Htike Muhammad [1 ]
Alam, A. H. M. Zahirul Mohd [1 ]
Islam, Rafiqul [1 ]
Khalifa, Othman O. [1 ]
Khan, Saman S. [1 ]
机构
[1] Int Islamic Univ Malaysia, Kuala Lumpur, Malaysia
关键词
D O I
10.1109/ICCCE.2008.4580808
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The liquid properties such as buoyancy, pressure at a depth, relative electrical permittivity, electrical conductivity, thermal conductivity, absorption of radiation, liquid surface reflection of sound or light waves, are used to design the different types of liquid level transducers for liquid level measurement in any process industry. The contact-type level-sensing transducers have the disadvantage that their characteristic properties may change due to physical or chemical reaction between the liquid and the probing material, and hence may affect accuracy besides their life time. The non-contact-type level-sensing probes may have longer life period, but they are comparatively costly and require various environmental and experimental precautionary measures when being used. In this paper, a low-cost non-contact capacitance type liquid level measuring technique has been designed and used for liquid identification objectives. The results obtained are very much consistent with the theoretical derivations.
引用
收藏
页码:1264 / 1269
页数:6
相关论文
共 50 条
  • [21] Non-contact characterization of MEMS dynamics
    Dräbenstedt, A
    Heimes, F
    Hettwer, D
    Rembe, C
    Steger, H
    Wörtge, M
    TM-TECHNISCHES MESSEN, 2005, 72 (11) : 601 - 608
  • [22] Non-contact microwave material characterization
    Glay, D
    Lasri, T
    Mamouni, A
    Leroy, Y
    SUBSURFACE AND SURFACE SENSING TECHNOLOGIES AND APPLICATIONS III, 2001, 4491 : 270 - 279
  • [23] Non-contact type pulse oximeter
    Joshi A.N.
    Nystrom A.L.
    La Belle J.T.
    Critical Reviews in Biomedical Engineering, 2019, 47 (02) : 141 - 151
  • [24] A Non-Contact Multifunctional Ultrasonic Transducer for Measurements and Non-Destructive Testing
    Suchkov, G. M.
    Taranenko, Yu. K.
    Khomyak, Yu. V.
    MEASUREMENT TECHNIQUES, 2016, 59 (09) : 990 - 993
  • [25] A Non-Contact Multifunctional Ultrasonic Transducer for Measurements and Non-Destructive Testing
    G. M. Suchkov
    Yu. K. Taranenko
    Yu. V. Khomyak
    Measurement Techniques, 2016, 59 : 990 - 993
  • [26] Non-contact nanoliter & picoliter liquid dispensing
    Koltay, P.
    Zengerle, R.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [27] Design and fabrication of non-contact fringing field capacitive sensor for liquid level measurement
    Islam, Tarikul
    Maurya, Om Prakash
    2019 IEEE 16TH INDIA COUNCIL INTERNATIONAL CONFERENCE (IEEE INDICON 2019), 2019,
  • [28] Non-contact Liquid Level Detection Method Based on Multilayer Spiking Neural Network
    Zhang, Jilun
    Zhu, Yi
    Li, Ying
    Chen, Fang
    Liu, Ying
    Qu, Hong
    JOURNAL OF ELECTRONICS & INFORMATION TECHNOLOGY, 2023, 45 (08) : 2759 - 2769
  • [29] Principle of a non-contact liquid level sensor using electromagnetic-acoustic resonators
    Lucklum, F.
    Jakoby, B.
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2009, 126 (1-2): : 3 - 7
  • [30] Non-Contact Opto-Fluidics-based Liquid Level Sensor for Harsh Environments
    Riza, Nabeel A.
    Reza, Syed Azer
    PHOTONICS IN THE TRANSPORTATION INDUSTRY: AUTO TO AEROSPACE III, 2010, 7675