Quantitative Evaluation of an Automated Cone-Based Breast Ultrasound Scanner for MRI-3D US Image Fusion

被引:26
|
作者
Nikolaev, Anton, V [1 ]
de Jong, Leon [1 ]
Weijers, Gert [1 ]
Groenhuis, Vincent [2 ]
Mann, Ritse M. [1 ]
Siepel, Francoise J. [2 ]
Maris, Bogdan M. [3 ]
Stramigioli, Stefano [2 ]
Hansen, Hendrik H. G. [1 ]
de Korte, Chris L. [1 ,4 ]
机构
[1] Radboud Univ Nijmegen, Med Ultrasound Imaging Ctr MUSIC, Dept Med Imaging, Med Ctr, NL-6525 GA Nijmegen, Netherlands
[2] Univ Twente, Fac Elect Engn Math & Comp Sci, Robot & Mechatron RAM Grp, NL-7522 NB Enschede, Netherlands
[3] Univ Verona, Dept Comp Sci, I-37129 Verona, Italy
[4] Univ Twente, Tech Med TechMed Ctr, Phys Fluids Grp, NL-7522 NB Enschede, Netherlands
基金
欧盟地平线“2020”;
关键词
Breast; Ultrasonic imaging; Lesions; Magnetic resonance imaging; Imaging; Three-dimensional displays; Biomedical imaging; phantom; image fusion; image quality; 3D US;
D O I
10.1109/TMI.2021.3050525
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Breast cancer is one of the most diagnosed types of cancer worldwide. Volumetric ultrasound breast imaging, combined with MRI can improve lesion detection rate, reduce examination time, and improve lesion diagnosis. However, to our knowledge, there are no 3D US breast imaging systems available that facilitate 3D US - MRI image fusion. In this paper, a novel Automated Cone-based Breast Ultrasound System (ACBUS) is introduced. The system facilitates volumetric ultrasound acquisition of the breast in a prone position without deforming it by the US transducer. Quality of ACBUS images for reconstructions at different voxel sizes (0.25 and 0.50 mm isotropic) was compared to quality of the Automated Breast Volumetric Scanner (ABVS) (Siemens Ultrasound, Issaquah, WA, USA) in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and resolution using a custom made phantom. The ACBUS image data were registered to MRI image data utilizing surface matching and the registration accuracy was quantified using an internal marker. The technology was also evaluated in vivo. The phantom-based quantitative analysis demonstrated that ACBUS can deliver volumetric breast images with an image quality similar to the images delivered by a currently commercially available Siemens ABVS. We demonstrate on the phantom and in vivo that ACBUS enables adequate MRI-3D US fusion. To our conclusion, ACBUS might be a suitable candidate for a second-look breast US exam, patient follow-up, and US guided biopsy planning.
引用
收藏
页码:1229 / 1239
页数:11
相关论文
共 50 条
  • [21] First Evaluation of the Diagnostic Accuracy of an Automated 3D Ultrasound System in a Breast Screening Setting
    Stoeblen, Frank
    Landt, Solveig
    Stelkens-Gebhardt, Ruth
    Sehouli, Jalid
    Rezai, Mahdi
    Kuemmel, Sherko
    ANTICANCER RESEARCH, 2011, 31 (08) : 2569 - 2574
  • [22] First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
    Schaefgen, Benedikt
    Juskic, Marija
    Hertel, Madeleine
    Barr, Richard G.
    Radicke, Marcus
    Stieber, Anne
    Hennigs, Andre
    Riedel, Fabian
    Sohn, Christof
    Heil, Joerg
    Golatta, Michael
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2021, 304 (02) : 559 - 566
  • [23] First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
    Schaefgen, B.
    Juskic, M.
    Heil, J.
    Harcos, A.
    Radicke, M.
    Hertel, M.
    Schuetz, F.
    Sohn, C.
    Golatta, M.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2020, 80 (06) : E58 - E58
  • [24] First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
    Schaefgen, B.
    Juskic, M.
    Heil, J.
    Harcos, A.
    Radicke, M.
    Hertel, M.
    Schuetz, F.
    Sohn, C.
    Golatta, M.
    GEBURTSHILFE UND FRAUENHEILKUNDE, 2020, 80 (10) : E106 - E106
  • [25] First proof-of-concept evaluation of the FUSION-X-US-II prototype for the performance of automated breast ultrasound in healthy volunteers
    Benedikt Schaefgen
    Marija Juskic
    Madeleine Hertel
    Richard G. Barr
    Marcus Radicke
    Anne Stieber
    André Hennigs
    Fabian Riedel
    Christof Sohn
    Joerg Heil
    Michael Golatta
    Archives of Gynecology and Obstetrics, 2021, 304 : 559 - 566
  • [26] Quantitative 3-D diagnostic ultrasound imaging using a modified transducer array and an automated image tracking technique
    Hossack, JA
    Sumanaweera, TS
    Napel, S
    Ha, JS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1029 - 1038
  • [27] Clustering based quantitative breast density assessment using 3D transmission ultrasound
    Malik, Bilal H.
    Lee, Sanghyeb
    Natesan, Rajni
    Wiskin, James W.
    MEDICAL IMAGING 2020: ULTRASONIC IMAGING AND TOMOGRAPHY, 2020, 11319
  • [28] Accuracy of Volume Measurement Using 3D Ultrasound and Fusion of Different Modalities (3D US-CT, 3D US-MRI) for Prostate Cancer Treatment
    Baek, J.
    Chung, K.
    Kim, M.
    An, S.
    Oh, Y.
    Na, T.
    Cho, S.
    Kim, D.
    Lee, R.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Deep learning-based breast lesion localization and segmentation in 3d automated breast ultrasound (3d abus) images
    Lertsatittanakron, S.
    Thongchai, P.
    Chaicharoen, P.
    Arora, R.
    Siripaibun, J.
    Kummanee, P.
    Pharksuwan, P.
    Fuangrod, T.
    BREAST, 2023, 68 : S114 - S115
  • [30] Establishment and evaluation of a 3D quantitative analysis method for dental plaque based on an intraoral scanner technique
    Guo, Suli
    Chen, Hu
    Zhang, Yaopeng
    Gao, Li
    Wu, Feng
    Sun, Yuchun
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2024, 27 (02) : 141 - 149