High voltage system for the CMS forward calorimeter

被引:4
|
作者
Akchurin, N.
Atramentov, O.
Dimitrov, L.
Hauptman, J.
Kim, H.
Los, S.
Sergeev, S.
Vankov, I.
机构
[1] Inst Nucl Energy Res, Sofia 1784, Bulgaria
[2] Texas Tech Univ, Lubbock, TX 79409 USA
[3] Iowa State Univ, Ames, IA 50011 USA
[4] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
[5] Joint Inst Nucl Res, Dubna, Russia
关键词
calorimeter; photomultiplier; power supply system;
D O I
10.1016/j.nima.2006.11.057
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The power supply system developed for the photomultipliers (PMTs) of the forward calorimeter (HF) of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider is described. The 1728 PMTs of the HF are divided into 24 clusters of 72 with similar gain value. All of the PMTs within each cluster are powered by the same three high voltage (HV) power supplies, making a total of only 72 power supplies in the entire system. In this so-called parallel dynode voltage distribution, the three HV power supplies can be adjusted from 0 to -2000, -800, and -400V, respectively. All output voltages are floating to facilitate a single-point ground configuration. The system is computer controlled and integrated into the CMS detector slow control facility. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:618 / 623
页数:6
相关论文
共 50 条
  • [31] The silicon sensors for the High Granularity Calorimeter of CMS
    Paulitsch, Peter
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 978
  • [32] An overview of the CMS High-Granularity Calorimeter
    Amendola, Chiara
    CMS Collaboration
    JOURNAL OF INSTRUMENTATION, 2025, 20 (01):
  • [33] The digital readout system for the CMS electromagnetic calorimeter
    Lofstedt, B
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 251 - 254
  • [34] Operational experience with the CMS hadronic calorimeter system
    Yetkin, Taylan
    XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010), 2011, 293
  • [35] The digital readout system for the CMS electromagnetic calorimeter
    Lofstedt, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2): : 433 - 439
  • [36] The CMS Electromagnetic Calorimeter Detector Control System
    Di Calafiori, D.
    Adzic, P.
    Dissertori, G.
    Holme, O.
    Jovanovic, D.
    Li, S-W
    Lustermann, W.
    Milenovic, P.
    Puzovic, J.
    Zelepoukine, S.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2010), 2011, 331
  • [37] THE HIGH-VOLTAGE MONITOR SYSTEM FOR THE CALORIMETER OF THE OBELIX EXPERIMENT
    BERTIN, A
    BRUSCHI, M
    CAPPONI, M
    CEREDA, B
    DANTONE, I
    DECASTRO, S
    GALLI, D
    GIACOBBE, B
    MARCONI, U
    MASSA, I
    PICCINNI, M
    POLI, M
    SEMPRINICESARI, N
    SPIGHI, R
    VECCHI, S
    VEZZANI, A
    VILLA, M
    VITALE, A
    ZOCCOLI, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (2-3): : 391 - 398
  • [38] Simulation of π0-γ Separation Study for Proposed CMS Forward Electromagnetic Calorimeter
    Roy, Ashim
    Jain, Shilpi
    Banerjee, Sunanda
    Bhattacharya, Satyaki
    Majumder, Gobinda
    XXVII IUPAP CONFERENCE ON COMPUTATIONAL PHYSICS (CCP2015), 2016, 759
  • [39] The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype
    Acar, B.
    Adamov, G.
    Adloff, C.
    Afanasiev, S.
    Akchurin, N.
    Akgun, B.
    Alhusseini, M.
    Alison, J.
    Altopp, G.
    Alyari, M.
    An, S.
    Anagul, S.
    Andreev, I
    Andrews, M.
    Aspell, P.
    Atakisi, I. A.
    Bach, O.
    Baden, A.
    Bakas, G.
    Bakshi, A.
    Banerjee, S.
    Bargassa, P.
    Barney, D.
    Becheva, E.
    Behera, P.
    Belloni, A.
    Bergauer, T.
    Besancon, M.
    Bhattacharya, S.
    Bhattacharya, S.
    Bhowmik, D.
    Bloch, P.
    Bodek, A.
    Bombardi, G.
    Bonanomi, M.
    Bonnemaison, A.
    Bonomally, S.
    Borg, J.
    Bouyjou, F.
    Braga, D.
    Brashear, J.
    Brondolin, E.
    Bryant, P.
    Bueghly, J.
    Bilki, B.
    Burkle, B.
    Butler-Nalin, A.
    Callier, S.
    Calvet, D.
    Cao, X.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (04)
  • [40] The CMS Electromagnetic Calorimeter detector control and monitoring system
    Hintz, W.