High voltage system for the CMS forward calorimeter

被引:4
|
作者
Akchurin, N.
Atramentov, O.
Dimitrov, L.
Hauptman, J.
Kim, H.
Los, S.
Sergeev, S.
Vankov, I.
机构
[1] Inst Nucl Energy Res, Sofia 1784, Bulgaria
[2] Texas Tech Univ, Lubbock, TX 79409 USA
[3] Iowa State Univ, Ames, IA 50011 USA
[4] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
[5] Joint Inst Nucl Res, Dubna, Russia
关键词
calorimeter; photomultiplier; power supply system;
D O I
10.1016/j.nima.2006.11.057
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The power supply system developed for the photomultipliers (PMTs) of the forward calorimeter (HF) of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider is described. The 1728 PMTs of the HF are divided into 24 clusters of 72 with similar gain value. All of the PMTs within each cluster are powered by the same three high voltage (HV) power supplies, making a total of only 72 power supplies in the entire system. In this so-called parallel dynode voltage distribution, the three HV power supplies can be adjusted from 0 to -2000, -800, and -400V, respectively. All output voltages are floating to facilitate a single-point ground configuration. The system is computer controlled and integrated into the CMS detector slow control facility. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:618 / 623
页数:6
相关论文
共 50 条
  • [1] High voltage system for the CMS electromagnetic calorimeter
    Bartoloni, A.
    Barone, L. M.
    Cavallari, F.
    Dafinei, I.
    del Re, D.
    Diemoz, M.
    Guerra, S.
    Longo, E.
    Meridiani, P.
    Organtini, G.
    Palma, A.
    Paramatti, R.
    Pellegrino, F.
    Rahatlou, S.
    Rovelli, C.
    Santanastasio, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 582 (02): : 462 - 468
  • [2] CMS hadronic forward calorimeter
    Merlo, JP
    NUCLEAR PHYSICS B, 1998, : 41 - 46
  • [3] High precision, low disturbance calibration system for the CMS Barrel Electromagnetic Calorimeter High Voltage apparatus
    Fasanella, G.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [4] The CMS-HF Forward Calorimeter Commissioning
    Gulmez, E.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 326 - 330
  • [5] The very forward CASTOR calorimeter of the CMS experiment
    Khachatryan, V.
    Sirunyan, A. M.
    Tumasyan, A.
    Adam, W.
    Ambrogi, F.
    Bergauer, T.
    Dragicevic, M.
    Eroe, J.
    Del Valle, A. Escalante
    Fruehwirth, R.
    Jeitler, M.
    Krammer, N.
    Lechner, L.
    Liko, D.
    Madlener, T.
    Mikulec, I.
    Pitters, F. M.
    Rad, N.
    Schieck, J.
    Schoefbeck, R.
    Spanring, M.
    Templ, S.
    Waltenberger, W.
    Wulz, C. -E.
    Zarucki, M.
    Chekhovsky, V.
    Litomin, A.
    Makarenko, V.
    Gonzalez, J. Suarez
    Beaumont, W.
    Darwish, M. R.
    De Wolf, E. A.
    Di Croce, D.
    Janssen, X.
    Kello, T.
    Lelek, A.
    Pieters, M.
    Sfar, H. Rejeb
    Van Haevermaet, H.
    Van Mechelen, P.
    Van Putte, S.
    Van Remortel, N.
    Blekman, F.
    Bols, E. S.
    Chhibra, S. S.
    D'Hondt, J.
    De Clercq, J.
    Lontkovskyi, D.
    Lowette, S.
    Marchesini, I.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (02)
  • [6] CMS electromagnetic calorimeter low voltage system for the front end electronics
    Dhawan, SK
    Betev, B
    Djambazov, L
    Dröge, M
    Lustermann, W
    Nardulli, A
    Pestalozzi, M
    Sharp, P
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1118 - 1122
  • [7] Phase 1 upgrade of the CMS forward hadronic calorimeter
    Noonan, D.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [8] Design, performance, and calibration of CMS forward calorimeter wedges
    S. Abdullin
    V. Abramov
    B. Acharya
    M. Adams
    N. Akchurin
    U. Akgun
    E.W. Anderson
    G. Antchev
    M. Arcidy
    S. Ayan
    S. Aydin
    M. Baarmand
    K. Babich
    D. Baden
    M.N. Bakirci
    Sud. Banerjee
    Sun. Banerjee
    R. Bard
    V. Barnes
    H. Bawa
    G. Baiatian
    G. Bencze
    S. Beri
    V. Bhatnagar
    A. Bodek
    H. Budd
    K. Burchesky
    T. Camporesi
    K. Cankoçak
    K. Carrell
    S. Cerci
    S. Chendvankar
    Y. Chung
    L. Cremaldi
    P. Cushman
    J. Damgov
    P. de Barbaro
    M. Deliomeroglu
    A. Demianov
    T. de Visser
    L. Dimitrov
    K. Dindar
    S. Dugad
    I. Dumanoglu
    F. Duru
    J. Elias
    D. Elvira
    I. Emeliantchik
    S. Eno
    E. Eskut
    The European Physical Journal C, 2008, 53 : 139 - 166
  • [9] Design, performance, and calibration of CMS forward calorimeter wedges
    Abdullin, S.
    Abramov, V.
    Acharya, B.
    Adams, M.
    Akchurin, N.
    Akgun, U.
    Anderson, E. W.
    Antchev, G.
    Arcidy, M.
    Ayan, S.
    Aydin, S.
    Baarmand, M.
    Babich, K.
    Baden, D.
    Bakirci, M. N.
    Banerjee, Sud.
    Banerjee, Sun.
    Bard, R.
    Barnes, V.
    Bawa, H.
    Baiatian, G.
    Bencze, G.
    Beri, S.
    Bhatnagar, V.
    Bodek, A.
    Budd, H.
    Burchesky, K.
    Camporesi, T.
    Cankocak, K.
    Carrell, K.
    Cerci, S.
    Chendvankar, S.
    Chung, Y.
    Cremaldi, L.
    Cushman, P.
    Damgov, J.
    de Barbaro, P.
    Deliomeroglu, M.
    Demianov, A.
    de Visser, T.
    Dimitrov, L.
    Dindar, K.
    Dugad, S.
    Dumanoglu, I.
    Duru, F.
    Elias, J.
    Elvira, D.
    Emeliantchik, I.
    Eno, S.
    Eskut, E.
    EUROPEAN PHYSICAL JOURNAL C, 2008, 53 (01): : 139 - 166
  • [10] The upgraded CMS Preshower high voltage system
    Vichoudis, P.
    Barney, D.
    Berberat, R.
    Di Calafiori, D.
    Holme, O.
    Honma, A.
    Kaufmann, S.
    Magnin, E.
    Petit, P.
    Trapani, P. P.
    Zelepukin, S.
    JOURNAL OF INSTRUMENTATION, 2013, 8