An Endoscopic Tri-Frequency (1 MHz, 5 MHz, 30 MHz) Transducer for Combined Imaging and Therapy

被引:0
|
作者
Mallay, Matthew [1 ]
Landry, Thomas [1 ]
Woodacre, Jeffrey [1 ]
Brown, Jeremy [2 ]
机构
[1] Dalhousie Univ, Biomed Engn, Halifax, NS, Canada
[2] Dalhousie Univ, Biomed Engn Elect & Comp Engn, Halifax, NS, Canada
关键词
transducer design; endoscope; focused ultrasound; imaging array; dual-beam histotripsy;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new endoscope design was built and tested that incorporates a 1 MHz pump transducer for increased peak pressure capability, and a 30 MHz imaging array in front designed to have minimal attenuation to the 5 MHz therapy transducer. Our novel design combines three different frequency transducers stacked together without affecting the device cross section. The thicknesses of the piezo and coupling layers were optimized using a COMSOL FEM model and maximize the peak pressure of the therapeutic pulse. This was tested in two designs. The first used an off-the-shelf piezo stack actuator for the pump transducer. In the second design, this is replaced by a PMN-PT Electrostrictor (PMN-38) transducer; E-Solder 3022 conductive epoxy was used for the coupling layer to provide an attenuating backing to the imaging array. The imaging transducer was a PZT5H laser cut 64-element array. A silicone Fresnel lens was cast on a PZT5A composite and characterized, and a concept for adapting it to this design was proposed. The therapy transducer with backing layers produced a pressure equivalent to an air-backed composite. Simultaneously pulsing the pump transducer increased the overall peak negative pressure. Adding the imaging transducer with coupling layer reduced the therapy signal by 3.7 dB in the first design, and 5.7 dB in the second design due to increased loss from the conductive epoxy coupling layer.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Design, Fabrication, and Characterization of a Single-Aperture 1.5-MHz/3-MHz Dual-Frequency HIFU Transducer
    Ma, Jianguo
    Guo, Sijia
    Wu, Di
    Geng, Xuecang
    Jiang, Xiaoning
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (07) : 1519 - 1529
  • [32] Determination of AC-DC Transfer Difference of SUT Calculable Thermal Voltage Converters in 1 MHz-30 MHz Frequency Range
    Grzenik, Michal
    Kampik, Marian
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [33] STUDY OF LOSS MECHANISMS OF MN-ZN FERRITES IN THE FREQUENCY FROM 1 MHZ TO 10 MHZ
    TUNG, MJ
    CHANG, WC
    LIU, CS
    LIU, TY
    CHEN, CJ
    TSENG, TY
    IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (06) : 3526 - 3528
  • [34] Automatic frequency control for maximizing RF power fed to ultrasonic transducer operating at 1 MHz
    Mizutani, Y
    Suzuki, T
    Ikeda, H
    Yoshida, H
    IAS '96 - CONFERENCE RECORD OF THE 1996 IEEE INDUSTRY APPLICATIONS CONFERENCE, THIRTY-FIRST IAS ANNUAL MEETING, VOLS 1-4, 1996, : 1585 - 1588
  • [35] A 15-MHz 1-3 Piezocomposite Concave Array Transducer for Ophthalmic Imaging
    Cha, Jung Hyui
    Kang, Byungwoo
    Jang, Jihun
    Chang, Jin Ho
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (11) : 1994 - 2004
  • [36] 5-CHANNEL (2KW PEP) 2-MHZ TO 30-MHZ DISTRIBUTION SYSTEM
    MURRAY, HD
    ARNESEN, DQ
    HOBBIS, CE
    REPORT OF NRL PROGRESS, 1973, (DEC): : 21 - 21
  • [37] A 30-W Flyback Converter Operating at 5 MHz
    Zhang, Zhemin
    Ngo, Khai D. T.
    Nilles, Jeff L.
    2014 TWENTY-NINTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2014, : 1415 - +
  • [38] 40 MHz high-frequency ultrafast ultrasound imaging
    Huang, Chih-Chung
    Chen, Pei-Yu
    Peng, Po-Hsun
    Lee, Po-Yang
    MEDICAL PHYSICS, 2017, 44 (06) : 2185 - 2195
  • [39] Characterization of the electromagnetic near-field absorption in layered biological tissue in the frequency range from 30 MHz to 6000 MHz
    Christ, A.
    Samaras, T.
    Klingenbock, A.
    Kuster, N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19): : 4951 - 4965
  • [40] 30/80 MHZ BIDIRECTIONAL DUAL -FREQUENCY IVUS FEASIBILITY EVALUATED IN VIVO AND FOR STENT IMAGING
    Munding, Chelsea E.
    Cherin, Emmanuel
    Alves, Natasha
    Goertz, David E.
    Courtney, Brian K.
    Foster, F. Stuart
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (08): : 2104 - 2112