Implementation of terbium-sensitized luminescence in sequential-injection analysis for automatic analysis of orbifloxacin

被引:11
|
作者
Llorent-Martinez, E. J. [1 ]
Ortega-Barrales, P. [1 ]
Molina-Diaz, A. [1 ]
Ruiz-Medina, A. [1 ]
机构
[1] Univ Jaen, Fac Expt Sci, Dept Phys & Anat Chem, Jaen 23071, Spain
关键词
Orbifloxacin; Sequential-injection analysis; Optosensor; Urine; Veterinary drug;
D O I
10.1007/s00216-008-2434-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Orbifloxacin (ORBI) is a third-generation fluoroquinolone developed exclusively for use in veterinary medicine, mainly in companion animals. This antimicrobial agent has bactericidal activity against numerous Gram-negative and Gram-positive bacteria. A few chromatographic methods for its analysis have been described in the scientific literature. Here, Coupling of sequential-injection analysis and solid-phase spectroscopy is described in order to develop, for the first time, a terbium-sensitized luminescent optosensor for analysis of ORBI. The cationic resin Sephadex-CM C-25 was used as solid support and measurements were made at 275/545 nm. The system had a linear dynamic range of 10-150 ng mL(-1), with a detection limit of 3.3 ng mL(-1) and an R.S.D. below 3% (n=10). The analyte was satisfactorily determined in veterinary drugs and dog and horse urine.
引用
收藏
页码:1397 / 1403
页数:7
相关论文
共 50 条
  • [21] Determination of Mycophenolic Acid in Plasma Samples Using the Terbium-Sensitized Luminescence Method
    Shayanfar, A.
    Ghavimi, H.
    Zolali, E.
    Jouyban, A.
    JOURNAL OF APPLIED SPECTROSCOPY, 2015, 82 (04) : 614 - 619
  • [22] SIMULTANEOUS DETERMINATION OF MEFENAMIC AND FLUFENAMIC ACIDS IN REAL SAMPLES BY TERBIUM-SENSITIZED LUMINESCENCE
    Murillo Pulgarin, J. A.
    Alanon Molina, A.
    Martinez Ferreras, F.
    ANALYTICAL LETTERS, 2012, 45 (18) : 2807 - 2822
  • [23] Simultaneous Determination of Mefenamic and Tolfenamic Acids in Real Samples by Terbium-Sensitized Luminescence
    J. A. Murillo Pulgarín
    A. Alañón Molina
    F. Martínez Ferreras
    Journal of Fluorescence, 2012, 22 : 1483 - 1492
  • [24] Simultaneous Determination of Mefenamic and Tolfenamic Acids in Real Samples by Terbium-Sensitized Luminescence
    Murillo Pulgarin, J. A.
    Alanon Molina, A.
    Martinez Ferreras, F.
    JOURNAL OF FLUORESCENCE, 2012, 22 (06) : 1483 - 1492
  • [25] Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method
    Jouyban, Abolghasem
    Shaghaghi, Masoomeh
    Manzoori, Jamshid L.
    Soleymani, Jafar
    Vaez-Gharamaleki, Jalil
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2011, 10 (04): : 695 - 704
  • [26] Determination of amlodipine using terbium-sensitized luminescence in the presence of europium(III) as a co-luminescence reagent
    Al-Kindy, Salma M. Z.
    Al-Snedi, Abdalla
    Suliman, Fakhr Eldin O.
    Al-Lawati, Haidar A. J.
    LUMINESCENCE, 2014, 29 (06) : 657 - 662
  • [27] Determination of ibuprofen in pharmaceutical formulations using time-resolved terbium-sensitized luminescence
    Al-Kindy, Salma M. Z.
    Suliman, Fakhr Eldin O.
    LUMINESCENCE, 2007, 22 (04) : 294 - 301
  • [28] Sequential-injection analysis: Principles, instrument construction, and demonstration by a simple experiment
    Economou, A
    Tzanavaras, PD
    Themelis, DG
    JOURNAL OF CHEMICAL EDUCATION, 2005, 82 (12) : 1820 - 1822
  • [29] Sequential Injection Analysis of Ciclopirox Olamine Using Lanthanide-Sensitized Luminescence Detection
    Llorent-Martinez, E. J.
    Jimenez-Lopez, J.
    Delgado-Blanca, I.
    Ortega-Barrales, P.
    Ruiz-Medina, A.
    ANALYTICAL LETTERS, 2013, 46 (11) : 1816 - 1825
  • [30] Determination of boron in water and pharmaceuticals by sequential-injection analysis and fluorimetric detection
    Economou, A
    Themelis, DG
    Bikou, H
    Tzanavaras, PD
    Rigas, PG
    ANALYTICA CHIMICA ACTA, 2004, 510 (02) : 219 - 224