Sulfur determination in concrete samples using laser-induced breakdown spectroscopy and limestone standards

被引:22
|
作者
Hrdlicka, Ales [1 ,3 ,4 ]
Hegrova, Jitka [2 ]
Novotny, Karel [3 ,4 ]
Kanicky, Viktor [1 ,3 ]
Prochazka, David [4 ,5 ]
Novotny, Jan [4 ,5 ]
Modlitbova, Pavlina [5 ]
Sladkova, Lucia [5 ]
Porizka, Pavel [4 ,5 ]
Kaiser, Jozef [4 ,5 ]
机构
[1] Masaryk Univ, Cent European Inst Technol, Kamenice 753-5, Brno 62500, Czech Republic
[2] Transport Res Ctr, Lisenska 33a, Brno 63600, Czech Republic
[3] Masaryk Univ, Fac Sci, Dept Chem, Kotlarska 2, CS-61137 Brno, Czech Republic
[4] AtomTrace As, Vedecko Tech Pk Prof Lista,Kolejni 9, Brno 61200, Czech Republic
[5] Brno Univ Technol, Cent European Inst Technol, Purkynova 123, Brno 61200, Czech Republic
关键词
Sulfur; Concrete; Limestone; Standard; Laser; Induced; Breakdown; Spectroscopy; Inductively coupled; Plasma; Mass spectrometry; Triple; Quadrupole; PLASMA-MASS SPECTROMETRY; ICP-MS/MS; CHLORINE; SYSTEM; TRACE; MS; PHOSPHORUS; ELEMENTS; CELL;
D O I
10.1016/j.sab.2018.01.015
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A LIBS equipment operating at 532 nm was optimized and used for sulfur determination in concrete samples. The influence of He atmosphere in a gas-tight chamber (1000-200 mbar) on S I 921.29 nm line sensitivity, signal-to-background and signal-to-noise ratio was studied at gate delays 100-2000 ns. Wide range of gate delays from 500 to about 1000 ns and pressures from several hundreds of mbar to the atmospheric pressure can be used for the desired detection of sulfur. The LIBS quantification was done using a simple calibration method. A synthetic limestone enriched by defined amounts of sodium sulfate was newly employed for direct quantification of S in concrete. This powder material was pressed into pellets and ablated with the LIBS system. The average content of sulfur as SO3 in the samples was 0.41-0.70 wt% by LIBS and 0.43-0.61 wt% by a reference standard procedure employing gravimetry and Inductively Coupled Plasma Triple Quad Mass Spectrometry (ICP-QQQMS). The uncertainty of the yielded LIBS results covers also the dispersion of the points in the calibration line and ranges from 16 to 28% at the probability level of 95%. The uncertainty of the ICP-QQQMS results was almost 10%. No correction on different signal response on the limestone and on the concrete was necessary. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 50 条
  • [31] Direct Determination of Ca, K, and Mg in Soy Leaf Samples Using Laser-Induced Breakdown Spectroscopy
    Borges Assis, Joao Victor
    Ferreira, Dennis da Silva
    Bocoli, Daniela de Assis
    Hoff Brait, Carlos Henrique
    Pereira-Filho, Edenir Rodrigues
    APPLIED SPECTROSCOPY, 2024, 78 (02) : 243 - 250
  • [32] Determination of Lanthanides in Fossil Samples Using Laser Induced Breakdown Spectroscopy
    Anzano, Jesus-Manuel
    Cajal, Jaime
    Lasheras, Roberto-Jesus
    Escudero, Miguel
    Canudo, Ignacio
    Laguna, Mariano
    Anwar, Jamil
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2017, 39 (04): : 516 - 523
  • [33] Quantitative determination of hydrogen isotopes using laser-induced breakdown spectroscopy
    Xing Y.
    Zou Z.
    Yang R.
    Ma W.
    Zou L.
    Lu L.
    Yang Z.
    He Jishu/Nuclear Techniques, 2023, 46 (02):
  • [34] Determination of zinc and iron in wheat using laser-induced breakdown spectroscopy
    Atta, Babar Manzoor
    Saleem, Muhammad
    Haq, S. U.
    Ali, Hina
    Ali, Zulfiqar
    Qamar, Maqsood
    LASER PHYSICS LETTERS, 2018, 15 (12)
  • [35] DETERMINATION OF CARBON CONTENT IN STEEL USING LASER-INDUCED BREAKDOWN SPECTROSCOPY
    AGUILERA, JA
    ARAGON, C
    CAMPOS, J
    APPLIED SPECTROSCOPY, 1992, 46 (09) : 1382 - 1387
  • [36] Determination of Zinc in Camel Skin Using Laser-Induced Breakdown Spectroscopy
    Asma Kamili
    Bernard Faye
    Yvon G. Mbesse Kongbonga
    Mohamed Bengoumi
    Nour Said Tligui
    Hassen Ghalila
    Biological Trace Element Research, 2020, 198 : 472 - 477
  • [37] Determination of Potassium in Farmland Soil Using Laser-Induced Breakdown Spectroscopy
    Dong Da-ming
    Zheng Wen-gang
    Zhao Chun-jiang
    Zhao Xian-de
    Jiao Lei-zi
    Zhang Shi-rui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (03) : 785 - 789
  • [38] Determination of Zinc in Camel Skin Using Laser-Induced Breakdown Spectroscopy
    Kamili, Asma
    Faye, Bernard
    Kongbonga, Yvon G. Mbesse
    Bengoumi, Mohamed
    Said Tligui, Nour
    Ghalila, Hassen
    BIOLOGICAL TRACE ELEMENT RESEARCH, 2020, 198 (02) : 472 - 477
  • [39] Isotopic determination with molecular emission using laser-induced breakdown spectroscopy and laser-induced radical fluorescence
    Zhu, Z. H.
    Li, J. M.
    Hao, Z. Q.
    Tang, S. S.
    Tang, Y.
    Guo, L. B.
    Li, X. Y.
    Zeng, X. Y.
    Lu, Y. F.
    OPTICS EXPRESS, 2019, 27 (02) : 470 - 482
  • [40] Determination of yttrium in titanium alloys using laser-induced breakdown spectroscopy assisted with laser-induced fluorescence
    Shen, M.
    Li, C. M.
    Na, D.
    Hao, Z. Q.
    Li, X. Y.
    Guo, L. B.
    Lu, Y. F.
    Zeng, X. Y.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (04) : 658 - 662