Transcatheter Pulmonary Valve Implantation in Patients With Right Ventricular Outflow Tract Dysfunction: Early and Mid-Term Results

被引:0
|
作者
Biernacka, Elzbieta Katarzyna [1 ]
Ruzyllo, Witold [2 ]
Demkow, Marcin [2 ]
Kowalski, Miroslaw [1 ]
Spiewak, Mateusz [2 ,3 ]
Piotrowski, Walerian [4 ]
Kusmierczyk, Mariusz [5 ]
Banas, Slawomir [6 ]
Rozanski, Jacek [5 ]
Hoffman, Piotr [1 ]
机构
[1] Inst Cardiol, Dept Congenital Heart Dis, PL-04628 Warsaw, Poland
[2] Inst Cardiol, Dept Coronary Artery Dis & Struct Heart Di, PL-04628 Warsaw, Poland
[3] Inst Cardiol, Cardiac Magnet Resonance Unit, PL-04628 Warsaw, Poland
[4] Inst Cardiol, Dept Epidemiol Cardiovasc Dis Prevent & Hlth Prom, PL-04628 Warsaw, Poland
[5] Inst Cardiol, Dept Cardiac Surg & Transplantat, PL-04628 Warsaw, Poland
[6] Inst Cardiol, Dept Anesthesiol, PL-04628 Warsaw, Poland
来源
JOURNAL OF INVASIVE CARDIOLOGY | 2015年 / 27卷 / 06期
关键词
TPVI; pulmonary valve; patched right ventricular outflow tract (RVOT) dysfunction; HEART-VALVE; BIVENTRICULAR RESPONSE; BIOPROSTHETIC VALVES; STENT FRACTURE; CLINICAL-TRIAL; REPLACEMENT; POSITION; EXPERIENCE; CONDUIT; REGURGITATION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. The aim of this study was to determine early and long-term results after transcatheter pulmonary valve implantation (TPVI) performed with the use of Medtronic Melody and Edwards Sapien valves in patients with full conduit or patched right ventricular outflow tract (RVOT) dysfunction. Methods and Results. The study comprised 40 consecutive patients (full conduit, n = 25; RVOT patch, n = 15) who underwent TPVI between December 2008 and April 2012. TPVI was successfully performed in 37 patients (92.5%). The gradient across RVOT decreased from 82.96 +/- 37.90 mm Hg to 34.33 +/- 22.2 mm Hg on the day following TPVI (P<.001) and remained low at follow-up of 20.4 +/- 11.4 months. The competency of the pulmonary valve was restored and maintained during the follow-up. New York Heart Association class, right ventricle end-diastolic volume, and right ventricular ejection fraction all improved as soon as 1 month after the procedure. Infective endocarditis was observed in 4 patients (1 died). Four patients underwent surgeries due to endocarditis, homograft rupture, stent migration, and early valve compression. Conclusion. TPVI may be performed safely and effectively in patients with right ventricle-pulmonary artery conduit and in selected patients with patched RVOT.
引用
下载
收藏
页码:E82 / E89
页数:8
相关论文
共 50 条
  • [31] Impact of percutaneous pulmonary valve implantation for right ventricular outflow tract dysfunction on exercise recovery kinetics
    Lurz, Philipp
    Riede, Frank T.
    Taylor, Andrew M.
    Wagner, Robert
    Nordmeyer, Johannes
    Khambadkone, Sachin
    Kinzel, Peter
    Derrick, Graham
    Schuler, Gerhard
    Bonhoeffer, Philipp
    Giardini, Alessandro
    Daehnert, Ingo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (01) : 276 - 280
  • [32] Percutaneous pulmonary valve implantation in patients with right ventricular outflow tract dysfunction: a systematic review and meta-analysis
    Ran, Liyu
    Wang, Wuwan
    Secchi, Francesco
    Xiang, Yajie
    Shi, Wenhai
    Huang, Wei
    THERAPEUTIC ADVANCES IN CHRONIC DISEASE, 2019, 10
  • [33] A novel hybrid technique for transcatheter pulmonary valve implantation within a dilated native right ventricular outflow tract
    Travelli, Frances C.
    Herrington, Cynthia S.
    Ing, Frank F.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (02): : E145 - E146
  • [34] Mid-term outcomes of Contegra implantation for the reconstruction of the right ventricular outflow tract to proximal branch pulmonary arteries: Japan multicentre study
    Hoashi, Takaya
    Ichikawa, Hajime
    Hirose, Keiichi
    Horio, Naohiro
    Sakurai, Takahisa
    Matsuhisa, Hironori
    Ohsima, Yoshihiro
    Sakurai, Hajime
    Kasahara, Shingo
    Sakamoto, Kisaburo
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 33 (02) : 227 - 236
  • [35] Pulmonary percutaneous valve implantation in large native right ventricular outflow tract with 32 mm Myval transcatheter heart valve
    Rodriguez Ogando, Alejandro
    Ballesteros, Fernando
    Martinez, Jose Luis Zunzunegui
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (01) : E38 - E42
  • [36] Early leaflet thrombosis complicating transcatheter implantation of a Sapien 3 valve in a native right ventricular outflow tract
    Riahi, Mounir
    Blanke, Philipp
    Webb, John
    Carere, Ronald G.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) : 925 - 929
  • [37] Transcatheter Aortic Valve Implantation in Nonagenarians: Procedural Outcome and Mid-Term Results
    Scholtz, Smita
    Dimitriadis, Zisis
    Vlachojannis, Marios
    Piper, Cornelia
    Horstkotte, Dieter
    Wiemer, Marcus
    Gummert, Jan
    Fujita, Buntaro
    Benzinger, Michael
    Ensminger, Stephan M.
    Boergermann, Jochen
    Scholtz, Werner
    HEART LUNG AND CIRCULATION, 2018, 27 (06): : 725 - 730
  • [38] Percutaneous implantation of pulmonary valves for treatment of right ventricular outflow tract dysfunction
    Lurz, Philipp
    Bonhoeffer, Philipp
    CARDIOLOGY IN THE YOUNG, 2008, 18 (03) : 260 - 267
  • [39] Are We Ready for Transcatheter Pulmonary Valve Replacement in Native Right Ventricular Outflow Tract?
    Ruiz, Carlos E.
    Pasala, Tilak K. R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (16) : 1651 - 1653
  • [40] Percutaneous pulmonary valve implantation: A cost-effective strategy for management of right ventricular outflow tract dysfunction
    Coats, L
    Sun, F
    Deanfield, JE
    Mcginley, P
    Bonhoeffer, P
    Mcguire, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 239A - 240A