Corona-Imaging Colorimetric Method for Accurate Measurement of the Size of Water Droplets in an Expansion Chamber

被引:0
|
作者
Aoki, Hiroka [1 ]
Moteki, Nobuhiro [1 ]
Kondo, Yutaka [1 ]
机构
[1] Univ Tokyo, Grad Sch Sci, Dept Earth & Planetary Sci, Bunkyo Ku, Tokyo 1130033, Japan
基金
日本科学技术振兴机构;
关键词
LIGHT-SCATTERING; MIE SCATTERING; AEROSOL DROPLETS; IRIDESCENCE; COLOR;
D O I
10.1080/02786826.2013.824550
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Accurate and time-resolved measurement of the size of water droplets is a prerequisite for the study of the microphysical processes of cloud formation by using an expansion chamber. We developed a droplet sizing method that uses color images of coronae observed under illumination of a white-light beam, also known as the corona-imaging colorimetry (CIC) method. In the CIC method, RGB data from images obtained by a commercial digital camera are converted into standard colorimetric parameters. The droplet size is estimated by optimizing the agreement of the measured colorimetric parameters with those estimated from Mie theory. For polystyrene latex spheres suspended in water, the particles size estimated by the CIC method agrees to within 2% of the predetermined value. We apply this method to the time-resolved measurement of the size of water droplets formed in an expansion chamber. The CIC method is technically simple and enables accurate and instantaneous measurements of the size of droplets with diameters larger than about 10m, which is the typical size of cloud droplets that form in the atmosphere. Copyright 2013 American Association for Aerosol Research
引用
收藏
页码:1134 / 1143
页数:10
相关论文
共 50 条
  • [21] Improving the glass-filament method for accurate measurement of drying kinetics of liquid droplets
    Lin, SXQ
    Chen, XD
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2002, 80 (A4): : 401 - 410
  • [22] Determination of size and number density of water droplets by the measurement of intensity of scattered light
    Singh, N.
    Mohan, Avinash
    Mathematical Methods in Electromagnetic Theory, MMET, Conference Proceedings, 1998, 2 : 894 - 895
  • [23] EVALUATION OF PRESSURE CHAMBER METHOD FOR MEASUREMENT OF WATER STRESS IN CITRUS
    KAUFMANN, MR
    PROCEEDINGS OF THE AMERICAN SOCIETY FOR HORTICULTURAL SCIENCE, 1968, 93 (DEC): : 186 - &
  • [24] Accurate measurement of the radon exhalation rate of building materials using the closed chamber method
    Zhang, Lei
    Lei, Xing
    Guo, Qiuju
    Wang, Shanqiang
    Ma, Xinhua
    Shi, Zhilan
    JOURNAL OF RADIOLOGICAL PROTECTION, 2012, 32 (03) : 315 - 323
  • [25] Image Measurement of Water Droplets in Cathode of PEFC Based on Background Subtraction Method
    Nishida, K.
    Tanaka, S.
    Tsushima, S.
    Hirai, S.
    POLYMER ELECTROLYTE FUEL CELLS 11, 2011, 41 (01): : 419 - 428
  • [26] Non-intrusive measurement of the temperature and size distribution of water droplets in a flat fan spray
    Pan, Qi
    Zhang, Zijia
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 2024 - 2028
  • [27] Size determination of mixed liquid and frozen water droplets using interferometric out -of -focus imaging
    Kielar, Justin Jacquot
    Wu, Yingchun
    Coetmellec, Sebastien
    Lebrun, Denis
    Grehan, Gerard
    Brunel, Marc
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2016, 178 : 108 - 116
  • [28] Magnetic resonance imaging measurement of the contralateral normal meniscus is a more accurate method of determining meniscal allograft size than radiographic measurement of the recipient tibial plateau
    Prodromos, Chadwick C.
    Joyce, Brian T.
    Keller, Brett L.
    Murphy, Brian J.
    Shi, Kelvin
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (11): : 1174 - 1179
  • [29] Assessment of a colorimetric method for the measurement of low concentrations of peracetic acid and hydrogen peroxide in water
    Dominguez-Henao, Laura
    Turolla, Andrea
    Monticelli, Damiano
    Antonelli, Manuela
    TALANTA, 2018, 183 : 209 - 215
  • [30] ANLS: Adaptive Non-Linear Sampling Method for Accurate Flow Size Measurement
    Hu, Chengchen
    Liu, Bin
    Wang, Sheng
    Tian, Jia
    Cheng, Yu
    Chen, Yan
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2012, 60 (03) : 789 - 798