Corona-Imaging Colorimetric Method for Accurate Measurement of the Size of Water Droplets in an Expansion Chamber

被引:0
|
作者
Aoki, Hiroka [1 ]
Moteki, Nobuhiro [1 ]
Kondo, Yutaka [1 ]
机构
[1] Univ Tokyo, Grad Sch Sci, Dept Earth & Planetary Sci, Bunkyo Ku, Tokyo 1130033, Japan
基金
日本科学技术振兴机构;
关键词
LIGHT-SCATTERING; MIE SCATTERING; AEROSOL DROPLETS; IRIDESCENCE; COLOR;
D O I
10.1080/02786826.2013.824550
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Accurate and time-resolved measurement of the size of water droplets is a prerequisite for the study of the microphysical processes of cloud formation by using an expansion chamber. We developed a droplet sizing method that uses color images of coronae observed under illumination of a white-light beam, also known as the corona-imaging colorimetry (CIC) method. In the CIC method, RGB data from images obtained by a commercial digital camera are converted into standard colorimetric parameters. The droplet size is estimated by optimizing the agreement of the measured colorimetric parameters with those estimated from Mie theory. For polystyrene latex spheres suspended in water, the particles size estimated by the CIC method agrees to within 2% of the predetermined value. We apply this method to the time-resolved measurement of the size of water droplets formed in an expansion chamber. The CIC method is technically simple and enables accurate and instantaneous measurements of the size of droplets with diameters larger than about 10m, which is the typical size of cloud droplets that form in the atmosphere. Copyright 2013 American Association for Aerosol Research
引用
收藏
页码:1134 / 1143
页数:10
相关论文
共 50 条
  • [1] OPTICAL DETERMINATION OF SIZE OF FAST-GROWING WATER DROPLETS IN AN EXPANSION CLOUD CHAMBER
    WAGNER, P
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1973, 44 (01) : 181 - 183
  • [2] Direct and accurate measurement of size dependent wetting behaviors for sessile water droplets
    Jimin Park
    Hyung-Seop Han
    Yu-Chan Kim
    Jae-Pyeong Ahn
    Myoung-Ryul Ok
    Kyung Eun Lee
    Jee-Wook Lee
    Pil-Ryung Cha
    Hyun-Kwang Seok
    Hojeong Jeon
    Scientific Reports, 5
  • [3] Direct and accurate measurement of size dependent wetting behaviors for sessile water droplets
    Park, Jimin
    Han, Hyung-Seop
    Kim, Yu-Chan
    Ahn, Jae-Pyeong
    Ok, Myoung-Ryul
    Lee, Kyung Eun
    Lee, Jee-Wook
    Cha, Pil-Ryung
    Seok, Hyun-Kwang
    Jeon, Hojeong
    SCIENTIFIC REPORTS, 2015, 5
  • [4] NOTE ON OPTICAL DETERMINATION OF SIZE OF FAST-GROWING WATER DROPLETS IN AN EXPANSION CLOUD CHAMBER
    COHEN, A
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1974, 48 (03) : 525 - 525
  • [5] Erratum: Direct and accurate measurement of size dependent wetting behaviors for sessile water droplets
    Jimin Park
    Hyung-Seop Han
    Yu-Chan Kim
    Jae-Pyeong Ahn
    Myoung-Ryul Ok
    Kyung Eun Lee
    Jee-Wook Lee
    Pil-Ryung Cha
    Hyun-Kwang Seok
    Hojeong Jeon
    Scientific Reports, 7
  • [6] NOTE ON OPTICAL DETERMINATION OF SIZE OF FAST-GROWING WATER DROPLETS IN AN EXPANSION CLOUD CHAMBER, BY COHEN,A - REPLY
    WAGNER, P
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1974, 48 (03) : 526 - 526
  • [7] EXPANSION CHAMBER FOR MEASUREMENT OF RED CELL PERMEATION BY WATER
    SOLOMON, AK
    PAGANELLI, CV
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1954, 42 (03): : 612 - 612
  • [8] AN ACCURATE COLORIMETRIC METHOD FOR MEASUREMENT OF SULFAMINOHEXOSE IN HEPARINS AND HEPARAN SULFATES
    HURST, RE
    SETTINE, JM
    ANALYTICAL BIOCHEMISTRY, 1981, 115 (01) : 88 - 92
  • [9] Direct and accurate measurement of size dependent wetting behaviors for sessile water droplets (vol 5, 18150, 2015)
    Park, Jimin
    Han, Hyung-Seop
    Kim, Yu-Chan
    Ahn, Jae-Pyeong
    Ok, Myoung-Ryul
    Lee, Kyung Eun
    Lee, Jee-Wook
    Cha, Pil-Ryung
    Seok, Hyun-Kwang
    Jeon, Hojeong
    SCIENTIFIC REPORTS, 2017, 7
  • [10] Exploring the accurate size measurement method for two typical nanostructures basing on SEM imaging
    Zhang, Peng
    MICRON, 2019, 126