Micro-imaging system using scanning DC-SQUID microscope

被引:68
|
作者
Morooka, T [1 ]
Nakayama, S [1 ]
Odawara, A [1 ]
Ikeda, M [1 ]
Tanaka, S [1 ]
Chinone, K [1 ]
机构
[1] Seiko Instruments Inc, Matsudo, Chiba 2702222, Japan
关键词
D O I
10.1109/77.783782
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A micro-imaging system in a low temperature environment has been developed for the study of superconducting films and magnetic films and for the inspection of superconducting integrated circuits. The system consists of a micro DC-SQUID, a cryostat, a precise scanning stage, and a computer. Two different types of micro DC-SQUIDs were designed. One was a magnetometer (Bz) with a one-turn pick-up coil with a diameter of 10 mu m, and the other was a gradiometer (dBz/dx) with a planar first-order derivative pick-up coil. Each micro DC-SQUID was integrated on a 3mm x 3mm Si chip using thin Nb film fabrication technology. Preliminary experiments were made using the system and several magnetic images were obtained. We present observations of a thin superconducting Nb film pattern by applying the Meissner screening and the magnetic domains of a thin garnet ((YBi)(3)(FeAl)(5)O-12) film.
引用
收藏
页码:3491 / 3494
页数:4
相关论文
共 50 条
  • [21] SIMPLE DC-SQUID SYSTEM BASED ON A FREQUENCY MODULATED RELAXATION-OSCILLATOR
    MUCK, M
    HEIDEN, C
    IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (02) : 1151 - 1153
  • [22] Development of a heart monitoring system with high-Tc DC-SQUID gradiometers
    Friedrich-Schiller-Universitaet Jena, Jena, Germany
    J Low Temp Phys, 3-4 (527-532):
  • [23] DC-SQUID SYSTEM WITH FLEXIBLE PICKUP COIL CONNECTED BY A NOVEL SUPERCONDUCTING TECHNIQUE
    Chinone, K.
    Chiba, N.
    Nakayama, S.
    Shimizu, N.
    Kiryu, S.
    Kasai, N.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1993, 3 (01) : 1898 - 1901
  • [24] Magnetic evaluation of HTS magnetic shielding cylinders using an HTS dc-SQUID
    Mori, K
    Minemoto, T
    Itoh, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1999, 9 (02) : 4377 - 4380
  • [25] Resonance analysis using a high frequency simulation method for dc-SQUID amplifiers
    Wu, Wentao
    Liang, Tiantian
    Lin, Zhirong
    Wang, Yongliang
    Zhang, Guofeng
    Ying, Liliang
    Peng, Wei
    Li, Peizhan
    Zhang, Wen
    Shi, Shengcai
    Zhang, Shuo
    Liu, Zhi
    You, Lixing
    Wang, Zhen
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2021, 591
  • [26] Penetration of vortices into micro-superconductors observed with a scanning SQUID microscope
    Nishio, T
    Okayasu, S
    Suzuki, J
    Kadowaki, K
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2004, 412 : 379 - 384
  • [27] Micro-Scanning Error Correction Technique for an Optical Micro-Scanning Thermal Microscope Imaging System
    Meijing Gao
    Ying Han
    Qiushi Geng
    Yong Zhao
    Bozhi Zhang
    Liuzhu Wang
    Journal of Beijing Institute of Technology, 2019, 28 (03) : 510 - 518
  • [28] Micro-scanning error correction technique for an optical micro-scanning thermal microscope imaging system
    Gao, Mei-Jing
    Tan, Ai-Ling
    Yang, Ming
    Xu, Jie
    Zu, Zhen-Long
    Wang, Jing-Yuan
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC IMAGING/SPECTROSCOPY AND SIGNAL PROCESSING TECHNOLOGY, 2017, 10620
  • [29] DC-SQUID USING HIGH-CRITICAL-TEMPERATURE OXIDE SUPERCONDUCTORS.
    Nakane, Hideaki
    Nishino, Toshikazu
    Hirano, Mikio
    Takagi, Kazumasa
    Kawabe, Ushio
    Japanese Journal of Applied Physics, Part 2: Letters, 1987, 26 (10): : 1581 - 1582
  • [30] Low-noise biomagnetic measurements with a multichannel dc-SQUID system at 77 K
    Barthelmess, HJ
    Halverscheid, M
    Schiefenhövel, B
    Heim, E
    Schilling, M
    Zimmermann, R
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 657 - 660