A randomised comparison of the self-pressurised air-Q™ intubating laryngeal airway with the LMA Unique™ in children

被引:22
|
作者
Jagannathan, N. [1 ,2 ]
Sohn, L. E. [1 ,2 ]
Sawardekar, A. [1 ,2 ]
Shah, R. [1 ,2 ]
Ryan, K. [1 ]
Jagannathan, R. [1 ]
Anderson, K. [1 ]
机构
[1] Ann & Robert H Lurie Childrens Hosp Chicago, Dept Pediat Anesthesia, Chicago, IL USA
[2] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
MASK AIRWAY; PEDIATRIC-PATIENTS; TRACHEAL INTUBATION; I-GELTM; TRIAL; LMA-PROSEAL(TM); INSERTION; SEAL;
D O I
10.1111/j.1365-2044.2012.07199.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We conducted a randomised trial comparing the self-pressurised air-QTM intubating laryngeal airway (air-Q SP) with the LMA-Unique in 60 children undergoing surgery. Outcomes measured were airway leak pressure, ease and time for insertion, fibreoptic examination, incidence of gastric insufflation and complications. Median (IQR [range]) time to successful device placement was faster with the air-Q SP (12 (1015 [518])) s than with the LMA-Unique (14 (1217 [622]) s; p = 0.05). There were no statistically significant differences between the air-Q SP and LMA-Unique in initial airway leak pressures (16 (1418 [1029]) compared with 18 (1520 [1030]) cmH2O, p = 0.12), an airway leak pressures at 10 min (19 (1622 [1230]) compared with 20 (1622 [1030]) cmH2O, p = 0.81); fibreoptic position, incidence of gastric insufflation, or complications. Both devices provided effective ventilation without the need for airway manipulation. The air-Q SP is an alternative to the LMA-Unique should the clinician prefer a device not requiring cuff monitoring during anaesthesia.
引用
收藏
页码:973 / 979
页数:7
相关论文
共 50 条
  • [31] Evaluation of Ambu-Aura-i laryngeal mask as a conduit for endotracheal intubation. A comparison with Air-Q intubating laryngeal airway in adult surgical patients
    Soaida, Sherif M.
    Osman, Safinaz H.
    Ahmed, Abeer
    Saad, Dalia
    Selim, Mohamed A.
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2023, 39 (01): : 356 - 361
  • [32] Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults
    Williams, Daryl Lindsay
    Zeng, James M.
    Alexander, Karl D.
    Andrews, David T.
    ANESTHESIOLOGY RESEARCH AND PRACTICE, 2012, 2012
  • [33] A randomised comparison of the Portex Softseal™ laryngeal mask airway with the LMA-Unique™ during anaesthesia
    Cook, TM
    Trümpelmann, P
    Beringer, R
    Stedeford, J
    ANAESTHESIA, 2005, 60 (12) : 1218 - 1225
  • [34] Fiberoptic-guided tracheal tube placement through the air-Q® Intubating Laryngeal Airway: a performance study in a manikin
    Richard E. Galgon
    Kristopher M. Schroeder
    Christopher S. Schmidt
    Adrian A. Matioc
    Seungbong Han
    Adin-Cristian Andrei
    Aaron M. Joffe
    Journal of Anesthesia, 2011, 25 : 721 - 726
  • [36] The air-Q intubating laryngeal airway: new weight-based guidelines (Response to Dr. Parotto and colleagues)
    Jagannathan, Narasimhan
    PEDIATRIC ANESTHESIA, 2009, 19 (10) : 1029 - 1030
  • [37] Comparative study between Air-Q and Intubating Laryngeal Mask Airway when used as conduit for fiber-optic
    Abdel-Halim, Talaat M.
    El Enin, Mostafa A. Abo
    Elgoushi, Mohsen M.
    Afifi, Mohammed G.
    Atwa, Hesham S.
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2014, 30 (02) : 107 - 113
  • [39] Comparison of the air-Q ILA(TM) and the LMA-Fastrach (TM) in airway management during general anaesthesia
    Neoh, E. U.
    Choy, Y. C.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2012, 18 (03) : 150 - 155
  • [40] A study to compare Air-Q intubating laryngeal airway with Ambu Auragain laryngeal mask for blind tracheal intubation using Parker flex tip tube
    Lal, Jatin
    Bansal, Teena
    Somesh, Somesh
    Jain, Mamta
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2021, 37 (04) : 641 - 647