Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study

被引:9
|
作者
Tan, Sovira [1 ]
Yao, Jianhua [1 ]
Yao, Lawrence [1 ]
Ward, Michael M. [1 ]
机构
[1] NIAMSD, NIH, Bethesda, MD 20892 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 14期
关键词
SURFACE-BASED REGISTRATION; RADIOGRAPHIC PROGRESSION; SEGMENTATION;
D O I
10.1088/0031-9155/57/14/4683
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (qualitative human judgment) may compromise sensitivity. With newly available treatments, more precise measures of syndesmophytes are needed to determine whether treatment can slow rates of syndesmophyte growth. We previously presented a computer algorithm measuring syndesmophyte volumes and heights in the 3D space of CT scans. In this study, we present improvements to the original algorithm and evaluate the gain in precision as applied to an anthropomorphic vertebral phantom and patients. Each patient was scanned twice in one day, thus providing two syndesmophyte volume and height measures. The difference between those two measures (ideally zero) determines our algorithm's precision. The technical improvements to the algorithm decreased the mean volume difference (standard deviation) between scans from 3.01% (2.83%) to 1.31% (0.95%) and the mean height difference between scans from 3.16% (2.99%) to 1.56% (1.13%). The high precision of the improved algorithm holds promise for application to longitudinal clinical studies.
引用
收藏
页码:4683 / 4704
页数:22
相关论文
共 50 条
  • [21] Measurement of CT Dose to An HDPE Phantom Using Calorimetry: A Feasibility Study
    Chen-Mayer, H.
    Tosh, R.
    Bateman, F.
    Zimmerman, B.
    MEDICAL PHYSICS, 2012, 39 (06) : 3635 - 3635
  • [22] Evaluation of spatial precision and accuracy of cone-beam CT using an in vitro phantom model
    Bocca, Leonardo Favi
    Tiefenbach, Jakov
    Sonneborn, Claire
    Hogue, Olivia
    Dorn, Kristina
    Painter, Tracy
    Centeno, Ricardo S.
    Baker, Kenneth B.
    Machado, Andre G.
    JOURNAL OF NEUROSURGERY, 2024, 140 (03) : 849 - 855
  • [23] ANKYLOSING-SPONDYLITIS (AS) - AN APPROACH TO MEASUREMENT OF SEVERITY AND OUTCOME - ANKYLOSING-SPONDYLITIS ASSESSMENT QUESTIONNAIRE (ASAQ) - A CONTROLLED-STUDY
    NEMETH, R
    SMITH, F
    ELSWOOD, J
    CALIN, A
    BRITISH JOURNAL OF RHEUMATOLOGY, 1987, 26 : 69 - 70
  • [24] Cervix Cancer in a Patient With Ankylosing Spondylitis Using Etanercept: A Case Report
    Doruk, Pinar
    Adam, Mehmet
    Leblebici, Berrin
    TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 58 (02): : 162 - 164
  • [25] Evaluation of the Iranian versions of the bath ankylosing spondylitis disease activity index (BASDAI), the bath ankylosing spondylitis functional index (BASFI) and the patient acceptable symptom state (PASS) in patients with ankylosing spondylitis
    Bidad, Katayoon
    Fallahi, Sasan
    Mahmoudi, Mahdi
    Jamshidi, Ahmadreza
    Farhadi, Elham
    Meysamie, Alipasha
    Nicknam, Mohammad Hossein
    RHEUMATOLOGY INTERNATIONAL, 2012, 32 (11) : 3613 - 3618
  • [26] Patient evaluation of the German version of the ASAS/EULAR recommendations for the management of ankylosing spondylitis
    Kiltz, U.
    Feldtkeller, E.
    Braun, J.
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 2008, 67 (08): : 694 - +
  • [27] Evaluation and validation of the patient acceptable symptom state (PASS) in patients with ankylosing spondylitis (AS)
    Maksymowych, WP
    Richardson, R
    Mallon, C
    van der Heijde, D
    Boonen, A
    JOURNAL OF RHEUMATOLOGY, 2006, 33 (02) : 381 - 381
  • [28] Improving Scoring Precision and Internal Construct Validity of the Bath Ankylosing Spondylitis Disease Activity Index Using Rasch Measurement Theory
    Heaney, Alice
    McKenna, Stephen P.
    Hagell, Peter
    Sengupta, Raj
    JOURNAL OF RHEUMATOLOGY, 2020, 47 (03) : 354 - 361
  • [29] Evaluation of the Iranian versions of the bath ankylosing spondylitis disease activity index (BASDAI), the bath ankylosing spondylitis functional index (BASFI) and the patient acceptable symptom state (PASS) in patients with ankylosing spondylitis
    Katayoon Bidad
    Sasan Fallahi
    Mahdi Mahmoudi
    Ahmadreza Jamshidi
    Elham Farhadi
    Alipasha Meysamie
    Mohammad Hossein Nicknam
    Rheumatology International, 2012, 32 : 3613 - 3618
  • [30] Dose measurement study of the chest during a CT scan using a fabricated phantom
    Alzoubi, A. S.
    Alqahtani, F. F.
    RADIOPROTECTION, 2023, 58 (02) : 123 - 128