Post mortem results of a Laser-Optical system packaged for use in harsh environments

被引:0
|
作者
Bright, Michelle R. [1 ]
机构
[1] NNSAs Kansas City Plant, Kansas City, MO 64131 USA
关键词
Laser; Assembly; Harsh; Environments; Results;
D O I
10.1117/12.795936
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The design and packaging of laser-optical system was tested to harsh environments outside lab conditions and post mortem activities will be discussed. Previously, custom mounts and bonded optical assemblies were environmentally tested to ensure their survivability. The results verified the sub-assemblies would enable the design of a laser-optical initiation system that could be fielded for use in extreme conditions. The design package, which utilized the proven opto-mechanical sub-assemblies, was then tested to the same levels as the sub-assemblies. The test regiment encompassed the harshest environments currently utilized. Temperature tests were performed ranging from a maximum of +75 degrees C to a minimum of -55 degrees C, allowing for two hour soak at each temperature set point. Vibration tests were performed to a maximum level of 15.5 grms for forty seconds in each of three critical axes. Shock tests were performed to a maximum impulse level of 5700 G's for the sub-assemblies with a 1.1 millisecond long pulse; whereas the packaged laser system maximum level reached was 3700 G's at 1.1 millisecond long pulse. The laser-optical assembly was visually inspected and functionally tested before and after each test to verify survival. As designed, the system covers were laser welded shut for hermetic seal. The only open port was the laser output for testing and verification of laser performance. No optical cables were utilized. Therefore the visual inspection of the interior was performed post mortem. The post mortem results will be discussed as will the potential of redesigns on future packaging strategies.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Repeatability and reproducibility of post-mortem central corneal thickness measurements using a portable optical coherence tomography system in humans: a prospective multicenter study
    Pietro Emanuele Napoli
    Matteo Nioi
    Letizia Gabiati
    Michela Laurenzo
    Fabio De-Giorgio
    Vincenzo Scorcia
    Simone Grassi
    Ernesto d’Aloja
    Maurizio Fossarello
    Scientific Reports, 10
  • [42] Repeatability and reproducibility of post-mortem central corneal thickness measurements using a portable optical coherence tomography system in humans: a prospective multicenter study
    Napoli, Pietro Emanuele
    Nioi, Matteo
    Gabiati, Letizia
    Laurenzo, Michela
    De-Giorgio, Fabio
    Scorcia, Vincenzo
    Grassi, Simone
    D'Aloja, Ernesto
    Fossarello, Maurizio
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [43] Adhesive-free bonding homogenous fused-silica Fabry-Perot optical fiber low pressure sensor in harsh environments by CO2 laser welding
    Wang Wenhua
    Wu Weina
    Wu Shengxu
    Li Yongqiang
    Huang Cunyou
    Tian Xiuyun
    Fei Xianxiang
    Huang Jiang
    OPTICS COMMUNICATIONS, 2019, 435 : 97 - 101
  • [44] Automatic generation of a holographically shaped beam in an actual optical system for use in material laser processing
    Hayasaki, Yoshio
    Onodeara, Ryo
    Kumagai, Kota
    Hasegawa, Satoshi
    OPTICS EXPRESS, 2023, 31 (02) : 1982 - 1991
  • [45] Theoretical system approach to semiconductor laser diode with the use of an optoelectronic feedback and optical reflected power
    Celebi, FV
    Yildirim, R
    PHOTONICS: DESIGN, TECHNOLOGY, AND PACKAGING, 2004, 5277 : 397 - 403
  • [46] SIMPLE 1ST POSITIVE SYSTEM NITROGEN LASER FOR USE IN OPTICAL FIBER MEASUREMENTS
    FRANZEN, DL
    DANIELSON, BL
    DAY, GW
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1978, 14 (06) : 402 - 404
  • [47] Recent laser radar field test results gathered with the Rapid Optical Beam Steering (ROBS) system
    MacDonald, B
    Dunn, M
    Herr, D
    Hyman, H
    Leslie, D
    DeSandre, L
    LASER RADAR TECHNOLOGY AND APPLICATIONS, 1996, 2748 : 325 - 332
  • [48] Use of the Randox Evidence Investigator immunoassay system for near-body drug screening during post-mortem examination in 261 forensic cases
    McLaughlin, Poppy
    Maskell, Peter D.
    Pounder, Derrick
    Osselton, David
    FORENSIC SCIENCE INTERNATIONAL, 2019, 294 : 211 - 215
  • [49] Use of neuropsychological evaluation results in a VA healthcare system post-acute geriatric rehabilitation clinic
    Andren, Kitchen K. A.
    Kangas, K.
    Sood, A.
    Kherallah, Y.
    Reckow
    Stelmokas, J. E.
    Spencer, R. J.
    Bieliauskas, L. A.
    CLINICAL NEUROPSYCHOLOGIST, 2016, 30 (03) : 441 - 441
  • [50] Optimized design of a system of generating terawatt laser pulses by use of optical parametric chirped pulse amplification
    Liu, HJ
    Chen, GF
    Zhao, W
    Wang, YS
    Zhao, SH
    ACTA PHYSICA SINICA, 2001, 50 (09) : 1717 - 1722