Prediction of Fluid Responsiveness Using Pulse Pressure Variation in Infants Undergoing Ventricular Septal Defect Repair with Median Sternotomy or Minimally Invasive Right Thoracotomy

被引:9
|
作者
Han, Ding [1 ]
Liu, Ya-Guang [4 ]
Luo, Yi [2 ]
Li, Jia [3 ]
Chuan Ou-Yang [1 ,4 ]
机构
[1] Affiliated Childrens Hosp, Capital Inst Pediat, Dept Anesthesia, Beijing, Peoples R China
[2] Affiliated Childrens Hosp, Capital Inst Pediat, Div Cardiac Surg, Beijing, Peoples R China
[3] Capital Inst Pediat, Clin Physiol Lab, Beijing, Peoples R China
[4] Capital Med Univ, Affiliated Beijing Anzhen Hosp, Anesthesia Ctr, 2 Anzhen St, Beijing 100029, Peoples R China
关键词
Fluid responsiveness; Pulse pressure variation; Ventricular septal defect; Infants; Open heart; Pressure recording analytical method; RECORDING ANALYTICAL METHOD; OF-THE-LITERATURE; CARDIAC-SURGERY; CHILDREN; OUTPUT;
D O I
10.1007/s00246-016-1500-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fluid management is challenging in infants after cardiopulmonary bypass. Pulse pressure variation (PPV) derived from pressure recording analytical method (PRAM) is based on lung-heart interaction during mechanical ventilation. A prospective observational study conducted in operating room tested PPV to predict fluid responsiveness in ventricular septal defect infants. Infants in open chest conditions with median sternotomy (n = 26) or minimally invasive right thoracotomy (n = 29) undergoing ventricular septal defect repair were enrolled. After cardiopulmonary bypass and modified ultrafiltration, all patients received fluid challenge. PPV was recorded using PRAM along with heart rate, diastolic blood pressure, stroke volume index (SVI), and cardiac index (CI) before and after volume replacement. Patients were considered as responders to fluid loading when CI increased C15%. In infants with median sternotomy, 12 were responders and 14 non-responders. PPV in responders was higher than that in non-responders (24.7 +/- 6.4 vs. 16.6 +/- 5.0%, P< 0.01). Area under the curve was 0.85 (95% confidence interval, 0.69-1, P = 0.001) and cutoff value 19% with a sensitivity of 92% and a specificity of 71%. In infants with minimally invasive right thoracotomy, 16 were responders and 13 non-responders. PPV in responders was higher than that in non-responders (25.0 +/- 6.8 vs. 18.2 +/- 5.3, P< 0.01). Area under the curve was 0.83 (95 confidence interval, 0.66-0.98, P = 0.001) and cutoff value 18% with a sensitivity of 94% and a specificity of 69%. PPV sensitively predicts fluid responsiveness in ventricular septal defect infants after surgical repair in open chest conditions both with median sternotomy and minimally invasive right thoracotomy.
引用
收藏
页码:184 / 190
页数:7
相关论文
共 22 条
  • [21] Prediction of Fluid Responsiveness by a Non-invasive Respiratory Systolic Time Interval Variation Using Heart Sound Signals in Recipients Undergoing Liver Transplantation
    Kim, S. -H.
    Moon, Y. -J.
    Kim, J. -W.
    Song, J. -G.
    Hwang, G. -S.
    TRANSPLANTATION PROCEEDINGS, 2017, 49 (05) : 1082 - 1086
  • [22] Assessment of fluid responsiveness using pulse pressure variation, stroke volume variation, plethysmographic variability index, central venous pressure, and inferior vena cava variation in patients undergoing mechanical ventilation: a systematic review and meta-analysis
    Chaves, Renato Carneiro de Freitas
    Barbas, Carmen Silvia Valente
    Queiroz, Veronica Neves Fialho
    Neto, Ary Serpa
    Deliberato, Rodrigo Octavio
    Pereira, Adriano Jose
    Timenetsky, Karina Tavares
    Silva Junior, Joao Manoel
    Takaoka, Flavio
    de Backer, Daniel
    Celi, Leo Anthony
    Correa, Thiago Domingos
    CRITICAL CARE, 2024, 28 (01)