Total arch replacement with an open stent graft for acute type A aortic dissection: fate of the false lumen

被引:32
|
作者
Uchida, Naomichi [1 ]
Shibamura, Hidenori [1 ]
Katayama, Akira [1 ]
Shimada, Norimitsu [1 ]
Sutoh, Miwa [1 ]
机构
[1] Hiroshima City Asa Gen Hosp, Div Cardiovasc Surg, Asa Kita Ku, Hiroshima 7310293, Japan
关键词
Aortic dissection; Stent graft; False lumen; THORACIC AORTA; REPAIR;
D O I
10.1016/j.ejcts.2008.09.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To describe the fate of the false lumen remaining in the descending thoracic aorta after extensive primary repair of the thoracic aorta by the modified elephant trunk technique with a stent graft for acute type A aortic dissection, particularly the changes of the false lumen on enhanced CT scanning. Methods: The subjects were 65 consecutive patients who received arch replacement with an open stent graft for type A acute aortic dissection. CT scanning was performed at 1, 3, 12, 36, and 60 months postoperatively to detect thrombus formation, absorption of thrombus, and obliteration of the false lumen after its exclusion by the stent graft. The aorta was measured at four levels, which were the distal border of the stent graft, the middle and distal parts of the descending thoracic aorta, and the origin of the superior mesenteric artery. Results: Obliteration was recognized in all patients at the distal border of the stent graft and absorption of thrombus was seen in 90% at the middle of the descending thoracic aorta within 1 year after surgery. However, the false lumen remained patent at the superior mesenteric artery (SMA) level in 50% of the patients. Conclusions: In patients with acute type A aortic dissection, it is possible to perform extensive primary repair of the thoracic aorta with relative safety by stent grafting, and this method may reduce the necessity for further operations to manage a residual false lumen. (C) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 50 条
  • [31] Coil embolization of persistent false lumen after stent graft repair of type B aortic dissection
    San Norberto, Enrique Maria
    Manuel Gutierrez, Vicente
    Taylor, James
    Vaquero, Carlos
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (01) : 201 - 204
  • [32] Hemiarch or total arch replacement for type A aortic dissection?
    Avgerinos, Dimitrios
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 20 (01) : 127 - 127
  • [33] Total Arch Replacement for Distal Enlargement after Ascending Aortic Replacement for Acute Type A Aortic Dissection
    Yamashiro, Satoshi
    Kuniyoshi, Yukio
    Arakaki, Katsuya
    Inafuku, Hitoshi
    Morishima, Yuji
    Kise, Yuya
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 15 (05) : 318 - 323
  • [34] Uncovered stent-graft in the treatment for residual patent false lumen after surgical repair for acute type A aortic dissection
    Mastroroberto, Pasquale
    Chello, Massimo
    Jannelli, Gabriele
    Covino, Elvio
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 12 (02) : 202 - 204
  • [35] SYSTEMATIC TOTAL ARCH REPLACEMENT WITH THORAFLEX HYBRID GRAFT IN ACUTE TYPE A AORTIC DISSECTION: A SINGLE CENTRE EXPERIENCE
    Chivasso, P.
    Mastrogiovanni, G.
    Miele, M.
    Colombino, M.
    Triggiani, D.
    Cafarelli, F.
    Leone, R.
    Masiello, P.
    Iesu, S.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25
  • [36] Systematic total arch replacement with thoraflex hybrid graft in acute type A aortic dissection: A single centre experience
    Chivasso, Pierpaolo
    Mastrogiovanni, Generoso
    Bruno, Vito Domenico
    Miele, Mario
    Colombino, Mario
    Triggiani, Donato
    Cafarelli, Francesco
    Leone, Rocco
    Rosapepe, Felice
    De Martino, Matteo
    Morena, Elvira
    Iesu, Ivana
    Citro, Rodolfo
    Masiello, Paolo
    Iesu, Severino
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [37] Acute type A aortic dissection and the consequences of a patent false lumen
    White, Abigail
    Bozso, Sabin J.
    Ouzounian, Maral
    Chu, Michael W. A.
    Moon, Michael C.
    JTCVS TECHNIQUES, 2021, 9 : 1 - 8
  • [38] Total aortic arch replacement using frozen elephant trunk technique with J Graft Open Stent Graft for distal aortic arch aneurysm
    Shigeki Koizumi
    Atsushi Nagasawa
    Tadaaki Koyama
    General Thoracic and Cardiovascular Surgery, 2018, 66 : 91 - 94
  • [39] Total aortic arch replacement using frozen elephant trunk technique with J Graft Open Stent Graft for distal aortic arch aneurysm
    Koizumi, Shigeki
    Nagasawa, Atsushi
    Koyama, Tadaaki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2018, 66 (02) : 91 - 94
  • [40] Patency of false lumen of the descending aorta is not altered by an extension of aortic replacement in acute type A dissection
    Sakaguchi, G
    Komiya, T
    Tamura, N
    Obata, S
    Masuyama, S
    Kimura, C
    Kobayashi, T
    CIRCULATION, 2004, 110 (17) : 590 - 590