Total arch replacement with an open stent graft for acute type A aortic dissection: fate of the false lumen

被引:32
|
作者
Uchida, Naomichi [1 ]
Shibamura, Hidenori [1 ]
Katayama, Akira [1 ]
Shimada, Norimitsu [1 ]
Sutoh, Miwa [1 ]
机构
[1] Hiroshima City Asa Gen Hosp, Div Cardiovasc Surg, Asa Kita Ku, Hiroshima 7310293, Japan
关键词
Aortic dissection; Stent graft; False lumen; THORACIC AORTA; REPAIR;
D O I
10.1016/j.ejcts.2008.09.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To describe the fate of the false lumen remaining in the descending thoracic aorta after extensive primary repair of the thoracic aorta by the modified elephant trunk technique with a stent graft for acute type A aortic dissection, particularly the changes of the false lumen on enhanced CT scanning. Methods: The subjects were 65 consecutive patients who received arch replacement with an open stent graft for type A acute aortic dissection. CT scanning was performed at 1, 3, 12, 36, and 60 months postoperatively to detect thrombus formation, absorption of thrombus, and obliteration of the false lumen after its exclusion by the stent graft. The aorta was measured at four levels, which were the distal border of the stent graft, the middle and distal parts of the descending thoracic aorta, and the origin of the superior mesenteric artery. Results: Obliteration was recognized in all patients at the distal border of the stent graft and absorption of thrombus was seen in 90% at the middle of the descending thoracic aorta within 1 year after surgery. However, the false lumen remained patent at the superior mesenteric artery (SMA) level in 50% of the patients. Conclusions: In patients with acute type A aortic dissection, it is possible to perform extensive primary repair of the thoracic aorta with relative safety by stent grafting, and this method may reduce the necessity for further operations to manage a residual false lumen. (C) 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 50 条
  • [1] Open-Branched Stent Graft Placement Makes Total Arch Replacement Easier for Acute Type A Aortic Dissection
    Chen, Liang-Wan
    Dai, Xiao-Fu
    Yang, Guo-Feng
    Zhang, Gui-Can
    Cao, Hua
    Wang, Qi-Min
    ANNALS OF THORACIC SURGERY, 2010, 89 (05): : 1688 - 1690
  • [2] Kinking of an open stent graft after total arch replacement with the frozen elephant technique for acute Type A aortic dissection
    Morisaki, Akimasa
    Isomura, Tadashi
    Fukada, Yasuhisa
    Yoshida, Minoru
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 26 (05) : 875 - 877
  • [3] Simplified total aortic arch replacement with an in situ stent graft fenestration technique for acute type A aortic dissection
    Hu, Xiaoping
    Wang, Zhiwei
    Ren, Zongli
    Hu, Rui
    Wu, Hongbing
    JOURNAL OF VASCULAR SURGERY, 2017, 66 (03) : 711 - 717
  • [4] Total aortic arch grafting for acute type A dissection: Analysis of residual false lumen
    Takahara, Y
    Sudo, Y
    Mogi, K
    Nakayama, M
    Sakurai, M
    ANNALS OF THORACIC SURGERY, 2002, 73 (02): : 450 - 454
  • [5] TOTAL ARCH GRAFT REPLACEMENT IN PATIENTS WITH ACUTE TYPE-A AORTIC DISSECTION
    KAZUI, T
    KIMURA, N
    YAMADA, O
    KOMATSU, S
    ANNALS OF THORACIC SURGERY, 1994, 58 (05): : 1462 - 1468
  • [6] Total aortic arch reconstruction with open placement of triple-branched stent graft for acute type A dissection
    Chen, Liang-Wan
    Dai, Xiao-Fu
    Zhang, Gui-Can
    Lu, Lin
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (06): : 1654 - U329
  • [7] The results of total arch graft implantation with open stent-graft placement for type A aortic dissection
    Kato, M
    Kuratani, T
    Kaneko, M
    Kyo, S
    Ohnishi, K
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 124 (03): : 531 - 540
  • [8] Total arch repair for acute type A aortic dissection with open placement of a modified triple-branched stent graft and the arch open technique
    Chen, Liang-Wan
    Wu, Xi-Jie
    Dai, Xiao-Fu
    Lu, Lin
    Liao, Dong-Shan
    Li, Chao
    Li, Qian-Zhen
    JOURNAL OF CARDIOTHORACIC SURGERY, 2014, 9
  • [9] Total arch repair for acute type A aortic dissection with open placement of a modified triple-branched stent graft and the arch open technique
    Liang-Wan Chen
    Xi-Jie Wu
    Xiao-Fu Dai
    Lin Lu
    Dong-Shan Liao
    Chao Li
    Qian-Zhen Li
    Journal of Cardiothoracic Surgery, 9
  • [10] Total Arch and Descending Aorta Replacement for Retrograde Type A Aortic Dissection After Endovascular Stent Graft Replacement for Complicated Type B Aortic Dissection
    Ishibashi, Kazuyuki
    Motokawa, Mamika
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (06)