Performance of an AASHTO Beam Bridge Prestressed with CFRP Tendons

被引:0
|
作者
Grace, Nabil [1 ,2 ]
Jensen, Elin [1 ,3 ]
Matsagar, Vasant [4 ]
Penjendra, Prasadu [3 ]
机构
[1] Lawrence Technol Univ, Coll Engn, Southfield, MI 48075 USA
[2] Lawrence Technol Univ, CIMR, Southfield, MI 48075 USA
[3] Lawrence Technol Univ, Dept Civil Engn, Southfield, MI 48075 USA
[4] Lawrence Technol Univ, Dept Civil Engn, CIMR, Southfield, MI 48075 USA
关键词
AASHTO beam; Bridge; CFRP; Ductility; Prestressed concrete; Progressive failure;
D O I
10.1061/(ASCE)BE.1943-5592.0000339
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corrosion-induced deterioration of steel RC highway bridges is one of the major distress types that can render a structurally deficient bridge before reaching the design life. One feasible solution to the problem is to replace the conventional steel reinforcement with noncorrosive carbon fiber-reinforced polymer (CFRP) reinforcements. However, the CFRP reinforcement as an internal reinforcement has not been explored in AASHTO-type prestressed concrete beam bridges. AASHTO-type beams have an I-type cross section with a bottom flange, and on integration of the deck slab, the final shape is a bulb-T section. This paper discusses the experimental investigation of a precast prestressed AASHTO control beam and a bridge model. A 12.5-m-long one-third scale AASHTO-type control beam was experimentally investigated for its flexural behavior when reinforced and prestressed with CFRP. Subsequently, a one-third scale bridge model made of five such beams was constructed, instrumented, and tested under both service and ultimate load conditions. As anticipated, the control beam and the bridge model failures were initiated by rupturing of the prestressing CFRP tendons at the bottom layer. The observed flexural response of the bridge model was in close agreement with that of the control beam. As expected, the failure mode was progressive, with extensive cracking of the bridge model, which gives significant warning prior to the ultimate collapse, overcoming issues related to the otherwise brittle behavior of the CFRP-reinforced structures. It is therefore highly recommended to provide the CFRP tendons in different layers along the depth of the beams to effectively address the issues related to brittle failure exhibited by CFRP reinforcements. DOI: 10.1061/(ASCE)BE.1943-5592.0000339. (C) 2013 American Society of Civil Engineers.
引用
收藏
页码:110 / 121
页数:12
相关论文
共 50 条
  • [21] Behavior of externally draped CFRP tendons in prestressed concrete bridges
    Grace, NF
    Abdel-Sayed, G
    PCI JOURNAL, 1998, 43 (05): : 88 - +
  • [22] Fatigue Behavior of UHPC Beams Prestressed with External CFRP Tendons
    Jia, Li
    Fang, Zhi
    Hu, Rui
    Pilakoutas, Kypros
    Huang, Zhengmeng
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2022, 26 (05)
  • [23] Fatigue prediction model of ultra-high-performance concrete beams prestressed with CFRP tendons
    Hu, Rui
    Fang, Zhi
    Jiang, Ruinian
    Xiang, Yu
    Liu, Chuanle
    ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (03) : 611 - 624
  • [24] Experimental Study on Shear Performance of Concrete Beams Reinforced with Externally Unbonded Prestressed CFRP Tendons
    Qi, Hetao
    Jiang, Haozhe
    Wang, Bing
    Zhuge, Ping
    FIBERS, 2024, 12 (03)
  • [25] Behavior of prestressed beam strengthened with external tendons
    Miyamoto, A
    Tei, K
    Nakamura, H
    Bull, JW
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (09): : 1033 - 1044
  • [26] Monitoring and response of CFRP prestressed concrete bridge
    Grace, NF
    Sensing Issues in Civil Structural Health Monitoring, 2005, : 95 - 105
  • [27] Performance of AASHTO-Type Bridge Model Prestressed with Carbon Fiber-Reinforced Polymer Reinforcement
    Grace, Nabil
    Ushijima, Kenichi
    Matsagar, Vasant
    Wu, Chenglin
    ACI STRUCTURAL JOURNAL, 2013, 110 (03) : 491 - 501
  • [28] Monitoring and response of CFRP prestressed concrete bridge
    De Stefano, A
    Ceravolo, R
    SENSING ISSUES IN CIVIL STRUCTURAL HEALTH MONITORING, 2005, : 85 - 94
  • [29] The strengthening of a steel bridge with prestressed CFRP strips
    Siwowski, Tomasz W.
    Siwowska, Paulina
    Wiater, Agnieszka
    9TH INTERNATIONAL SYMPOSIUM ON STEEL BRIDGES, 2018, 419
  • [30] Prestressed concrete bridge beam
    Concrete (London), 1998, 32 (09):