Development of a cold-neutron imaging detector based on thick gaseous electron multiplier

被引:8
|
作者
Cortesi, M. [1 ,2 ]
Zboray, R. [1 ]
Kaestner, A. [1 ]
Prasser, H. -M. [2 ]
机构
[1] Paul Scherrer Inst, CH-5234 Villigen, Switzerland
[2] ETH, Swiss Fed Inst Technol, CH-8092 Zurich, Switzerland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2013年 / 84卷 / 02期
关键词
RESOLUTION; PERFORMANCE;
D O I
10.1063/1.4793225
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present the results of our recent studies on a cold-neutron imaging detector prototype based on THick Gaseous Electron Multiplier (THGEM). The detector consists of a thin Boron layer, for neutron-to-charged particle conversion, coupled to two THGEM electrodes in cascade for charge amplification and a position-sensitive charge-readout anode. The detector operates in Ne/(5%) CF4, at atmospheric pressure, in a stable condition at a gain of around 10(4). Due to the geometrical structure of the detector elements (THGEM geometry and charge read-out anode), the image of detector active area shows a large inhomogeneity, corrected using a dedicated flat-filed correction algorithm. The prototype provides a detection efficiency of 5% and an effective spatial resolution of the order of 1.3 mm. (C) 2013 American Institute of Physics. [http://dx.doi.org/10.1063/1.4793225]
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A stopping layer concept to improve the spatial resolution of gas-electron-multiplier neutron detector
    周建晋
    周健荣
    周晓娟
    朱林
    杨建清
    杨桂安
    张毅
    丁宝卫
    胡碧涛
    孙志嘉
    段利敏
    陈元柏
    Chinese Physics B, 2022, (05) : 267 - 272
  • [32] A stopping layer concept to improve the spatial resolution of gas-electron-multiplier neutron detector
    Zhou, Jianjin
    Zhou, Jianrong
    Zhou, Xiaojuan
    Zhu, Lin
    Yang, Jianqing
    Yang, Guian
    Zhang, Yi
    Ding, Baowei
    Hu, Bitao
    Sun, Zhijia
    Duan, Limin
    Chen, Yuanbo
    CHINESE PHYSICS B, 2022, 31 (05)
  • [33] A comprehensive Monte Carlo simulation of the neutron response of multi-element microdosimetric detectors based on THick Gas Electron Multiplier
    Singh, R.
    Byun, S. H.
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1958 - 1962
  • [34] Development of an advanced two-dimensional microdosimetric detector based on THick Gas Electron Multipliers
    Darvish-Molla, Sahar
    Prestwich, William V.
    Byun, Soo Hyun
    MEDICAL PHYSICS, 2018, 45 (03) : 1241 - 1254
  • [35] Imaging gaseous detector based on micro-processing technology
    Tanimori, T
    Nishi, Y
    Ochi, A
    Nishi, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 188 - 195
  • [36] Performance Studies of Aluminium-Based Gas Electron Multiplier Detector
    Mindur, Bartosz
    Fiutowski, Tomasz
    Wiacek, Piotr
    SENSORS, 2024, 24 (13)
  • [37] Imaging gaseous detector based on micro-processing technology
    Department of Physics, Tokyo Institute of Technology, 152, Tokyo, Japan
    Nucl Instrum Methods Phys Res Sect A, 1-2 (188-195):
  • [38] Depletion layer imaging using a gaseous secondary electron detector in an environmental scanning electron microscope
    Phillips, MR
    Toth, M
    Drouin, D
    APPLIED PHYSICS LETTERS, 1999, 75 (01) : 76 - 78
  • [39] A robust large area x-ray imaging system based on 100 μm thick Gas Electron Multiplier
    Amaro, F. D.
    Mir, J. A.
    Carvalho, X.
    Azevedo, C. D. R.
    dos Santos, J. M. F.
    Natal da Luz, H.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [40] Thin cathode glass gas electron multiplier detector for carbon beam dose imaging
    Nakamura, Riichiro
    Fujiwara, Takeshi
    Koba, Yusuke
    Mitsuya, Yuki
    Chang, Weishan
    Tatsumoto, Ryuta
    Kawahara, Shuto
    Maehata, Keisuke
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2021, 58 (08) : 933 - 940