Noise propagation in resolution modeled PET imaging and its impact on detectability

被引:48
|
作者
Rahmim, Arman [1 ,2 ]
Tang, Jing [3 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21287 USA
[3] Oakland Univ, Dept Elect & Comp Engn, Rochester, MI 48309 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 19期
基金
美国国家科学基金会;
关键词
POSITRON-EMISSION-TOMOGRAPHY; PARTIAL-VOLUME CORRECTION; TIME-OF-FLIGHT; POINT-SPREAD FUNCTION; BAYESIAN RECONSTRUCTION; ITERATIVE DECONVOLUTION; COMPENSATION METHODS; SPATIAL-RESOLUTION; MYOCARDIAL SPECT; EM ALGORITHM;
D O I
10.1088/0031-9155/58/19/6945
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Positron emission tomography imaging is affected by a number of resolution degrading phenomena, including positron range, photon non-collinearity and inter-crystal blurring. An approach to this issue is to model some or all of these effects within the image reconstruction task, referred to as resolution modeling (RM). This approach is commonly observed to yield images of higher resolution and subsequently contrast, and can be thought of as improving the modulation transfer function. Nonetheless, RM can substantially alter the noise distribution. In this work, we utilize noise propagation models in order to accurately characterize the noise texture of reconstructed images in the presence of RM. Furthermore we consider the task of lesion or defect detection, which is highly determined by the noise distribution as quantified using the noise power spectrum. Ultimately, we use this framework to demonstrate why conventional trade-off analyses (e.g. contrast versus noise, using simplistic noise metrics) do not provide a complete picture of the impact of RM and that improved performance of RM according to such analyses does not necessarily translate to the superiority of RM in detection task performance.
引用
收藏
页码:6945 / 6968
页数:24
相关论文
共 50 条
  • [31] Increased lesion detectability and PET uptake values in PET/CT following image reconstruction with a spatial resolution model
    Andersen, F.
    Klausen, T. L.
    Loft, A.
    Beyer, T.
    Holm, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S368 - S368
  • [32] The correlation of visibilty noise and its impact on the radiometric resolution of an aperture synthesis radiometer
    Bará, J
    Camps, A
    Torres, F
    Corbella, I
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2000, 38 (05): : 2423 - 2426
  • [33] Curvature sensors: noise and its propagation
    Kellerer, Aglae
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2010, 27 (11) : A29 - A36
  • [34] NOISE - ITS PROPAGATION, MEASUREMENT AND CONTROL
    LORD, HW
    EVENSEN, HA
    EXPERIMENTAL MECHANICS, 1980, 20 (05) : N46 - N46
  • [35] Effect of patient thickness and scan duration on lesion detectability in PET oncology imaging
    Cheng, PM
    Kinahan, PE
    Comtat, C
    Lartizien, C
    Lewellen, TK
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 960 - 968
  • [36] mprovement of breast cancer detectability using a high resolution insert in a clinical PET scanner
    Komarov, Sergey
    Mathews, Aswin
    Kume, Maiko
    Wu, Heyu
    O'Sullivan, Joseph
    Tai, Yuan-Chuan
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [37] NEC and local image noise in PET imaging
    Stearns, CW
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3106 - 3108
  • [38] The impact of stratospheric resolution on the detectability of climate change signals in the free atmosphere
    Mitchell, D. M.
    Stott, P. A.
    Gray, L. J.
    Allen, M. R.
    Lott, F. C.
    Butchart, N.
    Hardiman, S. C.
    Osprey, S. M.
    GEOPHYSICAL RESEARCH LETTERS, 2013, 40 (05) : 937 - 942
  • [39] Noise and physical limits to maximum resolution of PET images
    Herraiz, J. L.
    Espana, S.
    Vicente, E.
    Vaquero, J. J.
    Desco, M.
    Udias, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 934 - 937
  • [40] THE DEPENDENCE OF OBJECT DETECTABILITY ON QUANTUM NOISE IN AN IMAGING-SYSTEM WITH VARIABLE SENSITIVITY
    WONG, R
    BEDNAREK, DR
    RUDI, S
    MEDICAL PHYSICS, 1982, 9 (04) : 637 - 637