Failure criteria for grouted concrete block masonry under biaxial compression

被引:8
|
作者
Liu, LP [1 ]
Tang, DX
Zhail, XM
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[2] Heilongjiang Univ, Sch Civil Engn, Harbin 150080, Peoples R China
关键词
masonry; concrete blocks; grout; failure criteria; biaxial compression; tension-compression;
D O I
10.1260/136943306776987001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Grouted concrete block masonry (GCBM) exhibits distinct directional properties. By the phenomenological approach, totally 86 tests on 3 kinds of macro-element were conducted for different principal stress ratios under plane stress, and 4 standard specimens were tested in shear. The anisotropic failure criteria are obtained in terms of normalized principal stress space. Comparisons of failure curves for 3 kinds of macro-element are made and it is found that the biaxial compressive strength when the applied stress direction and the material axis coincide is much greater than when the applied stress is inclined to the material axis. By the failure criteria and coordinate transformation, the law relating strength to orientation is obtained. It shows that the degree of anisotropy is affected by the difference of applied stresses. It behaves strongly only when one principal stress predominates and gradually becomes weak as the difference between the two principal compressive stresses decreases. The masonry seems to be isotropic in equal biaxial compression. The work conducted in this paper provides a basis for further theoretical study of the behavior of GCBM under biaxial stress.
引用
下载
收藏
页码:229 / 239
页数:11
相关论文
共 50 条
  • [41] Experimental behaviour of unreinforced and reinforced concrete block masonry walls under uniaxial compression
    Dharek, Manish S.
    Raghunath, S.
    Ashwin, C. P.
    MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 2462 - 2467
  • [42] BEHAVIOR OF CONCRETE HOLLOW-BLOCK MASONRY PRISMS UNDER AXIAL-COMPRESSION
    GANESAN, TP
    RAMAMURTHY, K
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (07): : 1751 - 1769
  • [43] SHEAR STRENGTH OF CONCRETE HOLLOW BLOCK MASONRY UNDER COMBINED SHEAR AND COMPRESSION LOADING
    Lue Weirong
    Wang Meng
    Liu Xijun
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON INSPECTION APPRAISAL REPAIRS AND MAINTENANCE OF STRUCTURES, VOLS 1 AND 2, 2010, : 771 - 775
  • [44] Compression behavior and failure mechanisms of concrete masonry prisms
    Köksal, HO
    Karakoç, C
    Yildirim, H
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2005, 17 (01) : 107 - 115
  • [45] Axial compressive behavior of grouted concrete block masonry columns confined by CFRP jackets
    Alotaibi, Khalid Saqer
    Galal, Khaled
    COMPOSITES PART B-ENGINEERING, 2017, 114 : 467 - 479
  • [46] STUDY OF PRECURSORS OF FAILURE UNDER BIAXIAL COMPRESSION
    SOBOLEV, GA
    PURE AND APPLIED GEOPHYSICS, 1975, 113 (1-2) : 45 - 49
  • [47] An experimental study and failure mechanism analysis on dynamic behaviors of plain concrete under biaxial compression-compression
    Yu, Zhenpeng
    Shen, Linsong
    Tang, Rui
    Huang, Qiao
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [48] Experimental Study and Failure Criterion Analysis of Rubber Fibre Reinforced Concrete under Biaxial Compression-Compression
    Hu, Yanli
    Gao, Peiwei
    Li, Furong
    Zhao, Zhiqing
    Yu, Zhenpeng
    JOURNAL OF RENEWABLE MATERIALS, 2023, 11 (04) : 2055 - 2073
  • [49] Preliminary study of concrete creep under biaxial compression
    Gao, H., 2001, Press of Tsinghua University (41):
  • [50] Predicting grouted concrete masonry prism strength
    Thompson, JJ
    Walloch, CT
    Thomas, RD