Force Calibration of a Dual-Probe Nanotweezer Using a Mechanical Lever

被引:0
|
作者
Xie, Hui [1 ]
Rong, Weibin [1 ]
Wu, Aiwen [1 ]
Yang, Chen [1 ]
Sun, Lining [1 ]
机构
[1] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Peoples R China
关键词
Dual-probe nanotweezer; noncontact force calibration; mechanical lever; nonlinearity compensation; MICROSCOPE; FRICTION; TIP;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a noncontact force calibration method in applications of the dual-probe nanotweezer. A 2 DOF mechanical lever has been developed to directly calibrate both the normal and lateral sensitivities of two optical levers used to independently measure normal and lateral forces applied on the nanotweezer. The mechanical lever is designed with a contiguration of two mutually perpendicular levers, each consists of two flexible hinges, sharing a same rotational center, Each lever can convert the translation into a nanoscale rotation angle that provides an accurate conversion between the photodiode voltage output and deflective angle of a cantilever. During the calibration, a cantilever is mounted on the mechanical lever and attached on the rotational center of the flexible hinges By making use of its nanomotion on the Z-axis and using an external motion on the barrier, this device can complete the local and full-range sensitivity calibrations of the optical levers without modifying the actual AFM or the cantilevers. Nonlinearities on both normal and lateral of the optical levers have been accurately compensated.
引用
收藏
页码:134 / 139
页数:6
相关论文
共 50 条
  • [31] A SIMPLIFIED DUAL-PROBE THYROID-UPTAKE SYSTEM
    MANTEL, J
    RUSKIN, RL
    CORRIGAN, KE
    RADIOLOGY, 1969, 93 (03) : 687 - &
  • [32] Evaluation of Supraesophageal Gastric Reflux in Children: A Study Using Dual-Probe pH Monitoring
    Chiou, Eric
    Rosen, Rachel L.
    Nurko, Samuel
    GASTROENTEROLOGY, 2009, 136 (05) : A512 - A512
  • [33] An Improved Dual-probe Approach to Measure Noise Source Impedance
    Bo, Zhao
    Min, Zhao
    Feng Zhiming
    Shui Limin
    Min, Yao
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 214 - 217
  • [34] Dual-probe laser interferometer for structural health monitoring (L)
    Hurlebaus, S
    Jacobs, LJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 119 (04): : 1923 - 1925
  • [35] A Novel Dual-Probe Adaptive Model for Image Change Detection
    Ma, Lin
    Zheng, Nanning
    Yuan, Zejian
    Zhang, Xuetao
    IEEE SIGNAL PROCESSING LETTERS, 2010, 17 (10) : 863 - 866
  • [36] Attentional Bias to Alcohol Information: a Novel Dual-Probe Task
    Todd, Jemma
    Downey, Jasmine
    Grafton, Ben
    MacLeod, Colin
    INTERNATIONAL JOURNAL OF BEHAVIORAL MEDICINE, 2022, 29 (06) : 820 - 826
  • [37] Micro-dissecting dual-probe testicular tubule assay
    Ramkumar, A.
    Chen, X.
    Paduch, D. A.
    Schlegel, P. N.
    Lal, A.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [38] Influence of grain boundary on electrical properties of organic crystalline grains investigated by dual-probe atomic force microscopy
    Hirose, Masaharu
    Tsunemi, Eika
    Kobayashi, Kei
    Yamada, Hirofumi
    APPLIED PHYSICS LETTERS, 2013, 103 (17)
  • [39] Dual-probe 24-h-pH monitoring in infants
    Lange, A
    GASTROENTEROLOGY, 2002, 122 (04) : A581 - A581
  • [40] Dual-probe SNOM for the near-field study of nanostructures
    Abbasirad, Najmeh
    Arslan, Dennis
    Fasold, Stefan
    Staude, Isabelle
    Setzpfandt, Frank
    Pertsch, Thomas
    2018 PHOTONICS NORTH (PN), 2018,