CRP detection from serum for chip-based point-of-care testing system

被引:56
|
作者
Kim, Chang-Hoon [1 ]
Ahn, Jae-Hyuk [1 ]
Kim, Jee-Yeon [1 ]
Choi, Ji-Min [1 ]
Lim, Kyung-Choon [2 ]
Park, Tae Jung [3 ]
Heo, Nam Su [4 ]
Lee, Hee Gu [5 ]
Kim, Jong-Wan [6 ]
Choi, Yang-Kyu [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Taejon 305701, South Korea
[2] Sungshin Womens Univ, Coll Nursing, Dept Nursing, Seoul 142732, South Korea
[3] Chung Ang Univ, Dept Chem, Seoul 156756, South Korea
[4] Korea Adv Inst Sci & Technol, BioProc Engn Res Ctr, Taejon 305701, South Korea
[5] Korea Res Inst Biosci & Biotechnol, Med Genom Res Ctr, Taejon 305806, South Korea
[6] DanKook Univ, Dept Lab Med, Cheonan 330714, South Korea
来源
关键词
C-reactive protein; CRP; Nanogap-embedded FET; FET-based biosensor; Point-of-care testing (POCT); C-REACTIVE PROTEIN; SURFACE-PLASMON RESONANCE; FIELD-EFFECT TRANSISTOR; BIOSENSORS; ELISA;
D O I
10.1016/j.bios.2012.08.047
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Most of point-of-care testing (POCT) to improve facilitates in diagnosis, treatment, and monitoring of patients. POCT technique has still remained a quantitatively and accurately detective effect. In this article, we demonstrated that real human C-reactive protein (CRP) in serum was detected for a chip-based point-of-care testing application based on a nanogap-embedded field effect transistor (FET), and the results were compared with those obtained via the enzyme-linked immunosorbent assay (ELISA) method. The limit of detection (LOD), determined from the standard curve, was 0.1 ng/ml, which is comparable to that of commercialized ELISAs. We evaluated that an improved detection range (0.1 ng/ml to 100 ng/ml) was achieved by comparing with commercialized ELISA. Control experiments to determine selectivity and to discern false-positive/false-negative rates were also performed. This report is the first description of the detection of CRP in human serum using a silicon-based biosensor. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:322 / 327
页数:6
相关论文
共 50 条
  • [31] Point-of-care testing system for digital single cell detection of MRSA directly from nasal swabs
    Schulz, Martin
    Calabrese, Silvia
    Hausladen, Florian
    Wurm, Holger
    Drossart, Dominik
    Stock, Karl
    Sobieraj, Anna M.
    Eichenseher, Fritz
    Loessner, Martin J.
    Schmelcher, Mathias
    Gerhardts, Anja
    Goetz, Ulrike
    Handel, Marina
    Serr, Annerose
    Haecker, Georg
    Li, Jia
    Specht, Mara
    Koch, Philip
    Meyer, Martin
    Tepper, Philipp
    Rother, Raimund
    Jehle, Michael
    Wadle, Simon
    Zengerle, Roland
    von Stetten, Felix
    Paust, Nils
    Borst, Nadine
    LAB ON A CHIP, 2020, 20 (14) : 2549 - 2561
  • [32] Distance-based microfluidic quantitative detection methods for point-of-care testing
    Tian, Tian
    Li, Jiuxing
    Song, Yanling
    Zhou, Leiji
    Zhu, Zhi
    Yang, Chaoyong James
    LAB ON A CHIP, 2016, 16 (07) : 1139 - 1151
  • [33] Point-of-care serum test for cancer detection based on the RECAF cancer marker
    Tcherkassova, Janneta
    Schmid, Ralph
    Hu, Xiaolong
    Lyubimova, Nina
    Moro, Ricardo
    TUMOR BIOLOGY, 2007, 28 : 101 - 101
  • [34] Toward the point-of-care testing of alkaline phosphatase in human serum
    Lucio-Rivera, Zachary
    Gudgel, Robert
    Gorski, Waldemar
    BIOSENSORS & BIOELECTRONICS, 2024, 265
  • [35] Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip
    Yin, Binfeng
    Wan, Xinhua
    Qian, Changcheng
    Sohan, A. S. M. Muhtasim Fuad
    Wang, Songbai
    Zhou, Teng
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [36] Upconversion Nanoparticles Based Sensing: From Design to Point-of-Care Testing
    Wu, Jizhong
    Wu, Jiaxi
    Wei, Wenya
    Zhang, Yong
    Chen, Quansheng
    SMALL, 2024, 20 (29)
  • [37] Detection System for Point-Of-Care Multiplexed Bead-Based Immunoassays
    de Haan, K.
    Dou, J.
    Aitchison, J. S.
    30TH ANNUAL CONFERENCE OF THE IEEE PHOTONICS SOCIETY (IPC), 2017, : 673 - 674
  • [38] Point-of-care testing: Administration within a health system
    Main, RI
    Kiechle, FL
    LABORATORY MEDICINE, 2000, 31 (08) : 453 - 459
  • [39] A chip-based electrophoresis system with electrochemical detection and hydrodynamic injection
    Backofen, U
    Matysik, FM
    Lunte, CE
    ANALYTICAL CHEMISTRY, 2002, 74 (16) : 4054 - 4059
  • [40] Development of a Point-of-Care System Based on White Light Reflectance Spectroscopy: Application in CRP Determination
    Tsounidi, Dimitra
    Koukouvinos, Georgios
    Christianidis, Vasilios
    Legaki, Evangelia
    Giogli, Vasiliki
    Panagiotopoulou, Konstantina
    Taka, Styliani
    Ekaterinidi, Zoi
    Kakabakos, Sotirios
    Raptis, Ioannis
    Petrou, Panagiota
    BIOSENSORS-BASEL, 2021, 11 (08):