Trace element determination in seawater by ICP-MS using online, offline and bath procedures of preconcentration and matrix elimination

被引:38
|
作者
Jerez Vegueria, Sergio Felipe [1 ,2 ]
Godoy, Jose Marcus [2 ,3 ]
de Campos, Reinaldo Calixto [2 ]
Goncalves, Rodrigo Araujo [2 ]
机构
[1] Univ Fed Fluminense, Dept Quim Analit, BR-24020150 Niteroi, RJ, Brazil
[2] Pontificia Univ Catolica Rio de Janeiro, Dept Quim, BR-22453900 Rio De Janeiro, RJ, Brazil
[3] Comissao Nacl Energia Nucl, Inst Radioprotecao & Dosimetria, BR-22780160 Rio De Janeiro, RJ, Brazil
关键词
ICP-MS; Trace elements; Seawater; PLASMA-MASS-SPECTROMETRY; ATOMIC-ABSORPTION SPECTROMETRY; RARE-EARTH ELEMENTS; SEA-WATER; FLOW-INJECTION; CHELATING RESIN; NATURAL-WATERS; REACTION CELL; METALS; IMINODIACETATE;
D O I
10.1016/j.microc.2012.05.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, procedures for multielemental determination of V. Mn, Co, Ni, Cu, Zn, Cd and Pb in sea-water using inductively coupled plasma mass spectrometry (ICP-MS) are described and evaluated. The methods involve chelation of the metals onto iminodiacetate resins: Toyopeare (R) AF Chelate-650 M. using both off and online column procedures and SPR-IDA (suspended particulate reagent iminodiacetate) using batch procedure. The recoveries from seawater samples ranged from 75 to 110%. Calibrations (external and/or standard addition) performed using calibration solutions with concentrations ranging from 0 to 5 mu g L-1 resulted in regression coefficients of 0.99-1. The limits of detection (LODs) ranged from 0.01 (for Co) to 0.08 mu g L-1 (for Zn) for the offline column procedure, from 0.004 (for Cd) to 0.147 mu g L-1 (for Ni) for the online column procedure and from 0.004 (for Cd) to 0.055 mu g L-1 (for Cu) for the batch procedure, appropriate to the required analysis. Accuracy was assessed by the analysis of seawater certified reference materials (CASS-3 and CASS-4), and good agreement between found and certified values was found. These methods were used for the determination of trace metals in produced water, interstitial water and seawaters from the Brazilian shore. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:121 / 128
页数:8
相关论文
共 50 条
  • [41] Determination of Ultra-trace Hg in Geothermal Water Using ICP-MS/MS
    Yan, Dong
    Guo, Wei
    Guo, Qinghai
    Jin, Lanlan
    Hu, Shenghong
    ATOMIC SPECTROSCOPY, 2024, 45 (06)
  • [42] Trace element analyses of fluid inclusions using laser ablation ICP-MS
    Li, Cong-ying
    Jiang, Yu-hang
    Zhao, Yan
    Zhang, Chan-chan
    Ling, Ming-xing
    Ding, Xing
    Zhang, Hong
    Li, Jie
    SOLID EARTH SCIENCES, 2018, 3 (01) : 8 - 15
  • [43] Trace element determination of single fluid inclusions in quartz by laser ablation ICP-MS
    McCandless, TE
    Lajack, DJ
    Ruiz, J
    Ghazi, AM
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1997, 21 (02): : 279 - 287
  • [44] Development of a procedure for the multi-element determination of trace elements in wine by ICP-MS
    Castiñeira, MM
    Brandt, R
    von Bohlen, A
    Jakubowski, N
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) : 553 - 558
  • [45] Determination of Trace Amounts of Bismuth in Steel by ICP-MS Through a Cascade-preconcentration and Separation Method
    Okano, Gen
    Igarashi, Shukuro
    Ohno, Osamu
    Yamamoto, Yuhei
    Saito, Shotaro
    Oka, Yoshio
    ISIJ INTERNATIONAL, 2015, 55 (01) : 332 - 334
  • [46] DOWNSIZED CHELATING RESIN-PACKED MINICOLUMN PRECONCENTRATION FOR MULTIELEMENT DETERMINATION OF TRACE METALS BY ICP-MS
    Rahmi, Dwinna
    MAKARA JOURNAL OF SCIENCE, 2010, 14 (02) : 121 - 128
  • [47] Automated matrix separation and preconcentration for the trace level determination of metal impurities in ultrapure inorganic salts by high-resolution ICP-MS
    Oliver Keil
    Joachim Dahmen
    Dietrich A. Volmer
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 694 - 699
  • [48] On-line Titanium Dioxide Nanotube Preconcentration for ICP-MS Determination of Trace Silver in Biological Samples
    Guo, Xinle
    Chen, Shizhong
    Zhang, Yan
    Lu, Dengbo
    ATOMIC SPECTROSCOPY, 2014, 35 (02) : 55 - 59
  • [49] Automated matrix separation and preconcentration for the trace level determination of metal impurities in ultrapure inorganic salts by high-resolution ICP-MS
    Keil, O
    Dahmen, J
    Volmer, DA
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (08): : 694 - 699
  • [50] Determination of rare earth elements in seawater by ICP-MS after preconcentration with a chelating resin-packed minicolumn
    Zhu, YB
    Itoh, A
    Fujimori, E
    Umemura, T
    Haraguchi, H
    JOURNAL OF ALLOYS AND COMPOUNDS, 2006, 408 : 985 - 988