Optimization of a customized Simultaneous Algebraic Reconstruction Technique algorithm for breast CT

被引:2
|
作者
Donato, Sandro [1 ,2 ]
Brombal, Luca [1 ,2 ]
Arfelli, Fulvia [1 ,2 ]
Fanti, Viviana [3 ,4 ]
Longo, Renata [1 ,2 ]
Oliva, Piernicola [5 ,6 ]
Rigon, Luigi [1 ,2 ]
Golosio, Bruno [3 ,4 ]
机构
[1] Univ Trieste, I-34127 Trieste, Italy
[2] Ist Nazl Fis Nucl, Div Trieste, I-34127 Trieste, Italy
[3] Univ Cagliari, I-09042 Cagliari, Italy
[4] Ist Nazl Fis Nucl, Div Cagliari, I-09042 Cagliari, Italy
[5] Univ Sassari, I-07100 Sassari, Italy
[6] Ist Nazl Fis Nucl, Div Cagliari, I-07100 Sassari, Italy
关键词
Breast CT; Iterative algorithms; Noise texture;
D O I
10.1109/NSS/MIC42101.2019.9060011
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Iterative CT reconstruction algorithms coupled with edge-preserving filters are attracting a growing interest in the field of biomedical X-ray imaging. In many cases the application of such algorithms results in an improved reconstruction quality when compared with filtered back-projection (FBP). Iterative algorithms commonly entail a decrease of image noise or, equivalently, an increase of contrast- to-noise ratio, while preserving image detail. Conversely, they modify the shape of noise power spectrum, producing a shift towards lower spatial frequencies with respect to FBP. This results in a "patchy" or "waxy" appearance of the reconstructed images. Changes in image texture affect radiologists' perception of image quality, possibly influencing their willingness to use an iterative algorithm in clinical practice. In this work we present a GPU implementation of a simultaneous algebraic reconstruction technique algorithm, combined with a bilateral regularization filter, and we discuss the optimization of the algorithm's parameters in terms of noise texture, selecting those parameters which preserve its "natural" appearance. We evaluated the performances of the algorithm, compared to FBP, both on a test phantom and on a surgical mastectomy sample by using contrast-to-noise ratio and spatial resolution metrics. Samples were imaged at the SYRMEP beamline of the Elettra synchrotron facility with a monochromatic beam (32 keV) in propagation-based phase-contrast configuration, delivering a clinically-compatible radiation dose of 5 mGy and using a large-area CdTe photon-counting detector. Results show, in the specific application on breast specimens, that the implemented algorithm can be tuned to preserve the noise texture and spatial resolution observed in FBP reconstructions, while improving contrast-to-noise ratio up to 30%.
引用
下载
收藏
页数:2
相关论文
共 50 条
  • [41] An Extended Algebraic Reconstruction Technique (E-ART) for Dual Spectral CT
    Zhao, Yunsong
    Zhao, Xing
    Zhang, Peng
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (03) : 761 - 768
  • [42] Modified simultaneous iterative reconstruction technique for fast, high-quality CT reconstruction
    Bappy, D. M.
    Jeon, Insu
    IET IMAGE PROCESSING, 2017, 11 (09) : 701 - 708
  • [43] GPS-based ionospheric tomography with a constrained adaptive simultaneous algebraic reconstruction technique
    Wen Debao
    Zhang Xiao
    Tong Yangjin
    Zhang Guangsheng
    Zhang Min
    Leng Rusong
    JOURNAL OF EARTH SYSTEM SCIENCE, 2015, 124 (02) : 283 - 289
  • [44] GPS-based ionospheric tomography with a constrained adaptive simultaneous algebraic reconstruction technique
    Wen D.B.
    Zhang X.
    Tong Y.
    Zhang G.
    Zhang M.
    Leng R.
    Journal of Earth System Science, 2015, 124 (2) : 283 - 289
  • [45] Adaptive simultaneous algebraic reconstruction technique for retrieving refractive index profiles of optical fiber
    Chang, Zheng
    Huang, Sujuan
    Wang, Tingyun
    Shang, Yi
    Zhang, Qianwu
    Yan, Cheng
    Zou, Fang
    OPTICAL ENGINEERING, 2016, 55 (09)
  • [46] A Systematic Performance Analysis of the Simultaneous Algebraic Reconstruction Technique (SART) for Limited Angle Tomography
    Van de Sompel, Dominique
    Brady, Michael
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2729 - 2732
  • [47] A new ionospheric tomographic algorithm - constrained multiplicative algebraic reconstruction technique (CMART)
    Wen Debao
    Liu Sanzhi
    JOURNAL OF EARTH SYSTEM SCIENCE, 2010, 119 (04): : 489 - 496
  • [48] A new ionospheric tomographic algorithm — constrained multiplicative algebraic reconstruction technique (CMART)
    Debao Wen
    Sanzhi Liu
    Journal of Earth System Science, 2010, 119 : 489 - 496
  • [49] Optimization of an algebraic reconstruction technique for generation of grain maps based on diffraction data
    Fu, XW
    Knudsen, E
    Poulsen, HF
    Herman, GT
    Carvalho, BM
    Liao, HY
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 261 - 273
  • [50] Simultaneous breast reconstruction
    F Gómez Bravo
    Breast Cancer Research, 7